{"id":34259,"date":"2026-08-02T08:00:00","date_gmt":"2026-08-02T08:00:00","guid":{"rendered":"https:\/\/jelproducts.nl\/?p=34259"},"modified":"2026-09-25T19:31:14","modified_gmt":"2026-09-25T18:31:14","slug":"what-is-luminous-intensity-and-why-is-it-important-in-industrial-lighting","status":"publish","type":"blog","link":"https:\/\/jelproducts.nl\/en\/blog\/wat-is-lichtsterkte-en-waarom-is-het-belangrijk-bij-industriele-verlichting\/","title":{"rendered":"What is illuminance and why is it important in industrial lighting?"},"content":{"rendered":"<div style=\"background:#0D2C4A;border-radius:8px;padding:28px 32px;margin:0 0 40px;\"><p style=\"margin:0 0 10px;font-family:Sora,system-ui,sans-serif;font-size:13px;line-height:1.4;font-weight:500;letter-spacing:1.8px;text-transform:uppercase;color:#7FA9CF;\">Short answer<\/p><p style=\"margin:0 0 14px;font-family:Sora,system-ui,sans-serif;font-size:22px;line-height:1.3;font-weight:600;letter-spacing:-0.4px;color:#FFFFFF;\">Candela determines whether the light from a luminaire mounted twenty metres high still reaches the floor.<\/p><p style=\"margin:0;font-size:16px;line-height:1.6;color:#D6E4F2;\">Luminous intensity is the amount of light that a luminaire or light source emits in a specific direction, expressed in candela (cd). In industrial environments, luminous intensity determines whether a workplace is safely and effectively illuminated: too little light increases the risk of errors and accidents, while too much unfocused light causes glare and energy waste. In this article, we answer the most frequently asked questions about luminous intensity,from basic principles to practical application in heavy industry.<\/p><div style=\"display:flex;flex-wrap:wrap;column-gap:24px;margin-top:24px;border-top:1px solid rgba(255,255,255,.14);\"><div style=\"flex:1 1 150px;padding-top:18px;\"><p style=\"margin:0;font-family:Sora,system-ui,sans-serif;font-size:30px;line-height:1.1;font-weight:600;letter-spacing:-0.8px;color:#FFFFFF;font-variant-numeric:tabular-nums;\"><span style=\"background:#FFE9BD;color:#0D2C4A;padding:0 6px;border-radius:3px;\">E = I \/ d\u00b2<\/span><\/p><p style=\"margin:6px 0 0;font-size:14px;line-height:1.5;color:#A9C6E2;\">lux directly below the luminaire: candela divided by the distance squared<\/p><\/div><div style=\"flex:1 1 150px;padding-top:18px;\"><p style=\"margin:0;font-family:Sora,system-ui,sans-serif;font-size:30px;line-height:1.1;font-weight:600;letter-spacing:-0.8px;color:#FFFFFF;font-variant-numeric:tabular-nums;\">40.000<span style=\"font-size:15px;font-weight:400;letter-spacing:0;color:#A9C6E2;\"> cd<\/span><\/p><p style=\"margin:6px 0 0;font-size:14px;line-height:1.5;color:#A9C6E2;\">gives 100 lux directly below at a distance of 20 metres<\/p><\/div><div style=\"flex:1 1 150px;padding-top:18px;\"><p style=\"margin:0;font-family:Sora,system-ui,sans-serif;font-size:30px;line-height:1.1;font-weight:600;letter-spacing:-0.8px;color:#FFFFFF;font-variant-numeric:tabular-nums;\">4 \u00d7<\/p><p style=\"margin:6px 0 0;font-size:14px;line-height:1.5;color:#A9C6E2;\">that much more luminous intensity is needed when the distance doubles<\/p><\/div><\/div><p style=\"margin:18px 0 0;font-size:13px;line-height:1.5;color:#7FA9CF;\">Inverse square law for light falling perpendicular to the surface. If the light falls at an angle, the cosine of the angle of incidence is added.<\/p><\/div>\n\n\n<h2 class=\"wp-block-heading\">How does luminous intensity differ from lumens and lux?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Three concepts that are often used interchangeably, but each measure something different. <strong>Light intensity<\/strong> (candela) indicates how much light a source emits in one specific direction. <strong>Lumen<\/strong> describes the total amount of light a luminaire emits in all directions combined. <strong>lux<\/strong> measure how much of that light actually falls on a surface, at a certain distance.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A useful example: a luminaire with many lumens does not automatically have high illuminance. If the light is widely dispersed, the beam is less intense in any given direction. A spotlight with the same lumens but a narrow beam has a much higher illuminance in that single direction. For industrial applications, this distinction is crucial, high illuminance ensures that light reaches far and is directed, which is essential for high masts, large halls, or outdoor locations.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The relationship between the three quantities in a row:<\/p>\n\n\n<figure style=\"margin:32px 0 36px;\"><table style=\"width:100%;border-collapse:collapse;border:0;table-layout:fixed;\"><thead><tr><th scope=\"col\" style=\"overflow-wrap:anywhere;hyphens:auto;background:transparent;border:0;border-bottom:1px solid #0D2C4A;padding:0 16px 12px 0;text-align:left;vertical-align:bottom;font-family:Sora,system-ui,sans-serif;font-size:13px;line-height:1.4;font-weight:500;letter-spacing:1.8px;text-transform:uppercase;color:#5E7288;width:36%;\">Quantity<\/th><th scope=\"col\" style=\"overflow-wrap:anywhere;hyphens:auto;background:transparent;border:0;border-bottom:1px solid #0D2C4A;padding:0 16px 12px 0;text-align:left;vertical-align:bottom;font-family:Sora,system-ui,sans-serif;font-size:13px;line-height:1.4;font-weight:500;letter-spacing:1.8px;text-transform:uppercase;color:#5E7288;\">What is it measuring<\/th><\/tr><\/thead><tbody><tr style=\"background:transparent;\"><td style=\"overflow-wrap:anywhere;hyphens:auto;background:transparent;border:0;border-bottom:1px solid #E2E7EE;padding:15px 16px 15px 0;vertical-align:top;font-size:15px;line-height:1.55;font-weight:500;color:#0D2C4A;\"><strong>Candela (cd):<\/strong><\/td><td style=\"overflow-wrap:anywhere;hyphens:auto;background:transparent;border:0;border-bottom:1px solid #E2E7EE;padding:15px 16px 15px 0;vertical-align:top;font-size:15px;line-height:1.55;color:#54687C;\">Luminous intensity in a specific direction<\/td><\/tr><tr style=\"background:transparent;\"><td style=\"overflow-wrap:anywhere;hyphens:auto;background:transparent;border:0;border-bottom:1px solid #E2E7EE;padding:15px 16px 15px 0;vertical-align:top;font-size:15px;line-height:1.55;font-weight:500;color:#0D2C4A;\"><strong>Lumen (lm):<\/strong><\/td><td style=\"overflow-wrap:anywhere;hyphens:auto;background:transparent;border:0;border-bottom:1px solid #E2E7EE;padding:15px 16px 15px 0;vertical-align:top;font-size:15px;line-height:1.55;color:#54687C;\">total luminous flux emitted by a luminaire<\/td><\/tr><tr style=\"background:transparent;\"><td style=\"overflow-wrap:anywhere;hyphens:auto;background:transparent;border:0;border-bottom:1px solid #E2E7EE;padding:15px 16px 15px 0;vertical-align:top;font-size:15px;line-height:1.55;font-weight:500;color:#0D2C4A;\"><strong>Lux (lx):<\/strong><\/td><td style=\"overflow-wrap:anywhere;hyphens:auto;background:transparent;border:0;border-bottom:1px solid #E2E7EE;padding:15px 16px 15px 0;vertical-align:top;font-size:15px;line-height:1.55;color:#54687C;\">illuminance on a surface (lumens per square meter)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<p class=\"wp-block-paragraph\">More background on the relationship between lumens and luminous flux can be found on the page about <a href=\"https:\/\/jelproducts.nl\/en\/luminous-flux-what-you-need-to-know\/\">Luminous flux and what you need to know<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Why is light intensity critical in industrial environments?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">On a factory floor, a construction site, or a <a href=\"https:\/\/jelproducts.nl\/en\/sectors\/havens-terminals-lighting\/\">haven terminal<\/a> work with heavy machinery, dangerous materials, and complex installations. Insufficient targeted lighting directly leads to reduced visibility and an increased safety risk, and that's precisely where the importance of light intensity comes in.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Industrial luminaires are often hung at great heights, sometimes twenty meters or more above the work floor. At that distance, the illuminance decreases rapidly if the luminaire's luminous intensity is too low. A luminaire with high luminous intensity in the correct beam shape ensures that light reaches the workspace with sufficient intensity, even at a great distance.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In addition, environmental factors play a role. Dust, vapor, heat, and corrosion can further reduce light output. In such conditions, a generous light intensity margin is not a luxury, but a necessity to guarantee reliable lighting throughout the entire lifespan of the installation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What illuminance level is required for different industrial applications?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The required illuminance varies greatly depending on the application and is determined by the mounting height, the area to be illuminated, the nature of the work, and applicable standards. For industrial workplaces in the Netherlands and Europe, guidelines apply based on the EN 12464-1 standard for indoor lighting and EN 12464-2 for outdoor locations.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Global guiding values per application:<\/p>\n\n\n<figure style=\"margin:32px 0 36px;\"><table style=\"width:100%;border-collapse:collapse;border:0;table-layout:fixed;\"><thead><tr><th scope=\"col\" style=\"overflow-wrap:anywhere;hyphens:auto;background:transparent;border:0;border-bottom:1px solid #0D2C4A;padding:0 16px 12px 0;text-align:left;vertical-align:bottom;font-family:Sora,system-ui,sans-serif;font-size:13px;line-height:1.4;font-weight:500;letter-spacing:1.8px;text-transform:uppercase;color:#5E7288;width:36%;\">Application<\/th><th scope=\"col\" style=\"overflow-wrap:anywhere;hyphens:auto;background:transparent;border:0;border-bottom:1px solid #0D2C4A;padding:0 16px 12px 0;text-align:left;vertical-align:bottom;font-family:Sora,system-ui,sans-serif;font-size:13px;line-height:1.4;font-weight:500;letter-spacing:1.8px;text-transform:uppercase;color:#5E7288;\">Guide value and luminous intensity<\/th><\/tr><\/thead><tbody><tr style=\"background:transparent;\"><td style=\"overflow-wrap:anywhere;hyphens:auto;background:transparent;border:0;border-bottom:1px solid #E2E7EE;padding:15px 16px 15px 0;vertical-align:top;font-size:15px;line-height:1.55;font-weight:500;color:#0D2C4A;\"><strong>Hallways and storage rooms:<\/strong><\/td><td style=\"overflow-wrap:anywhere;hyphens:auto;background:transparent;border:0;border-bottom:1px solid #E2E7EE;padding:15px 16px 15px 0;vertical-align:top;font-size:15px;line-height:1.55;color:#54687C;\">at least 100 lux at work surface height, low illuminance is sufficient at short distances<\/td><\/tr><tr style=\"background:transparent;\"><td style=\"overflow-wrap:anywhere;hyphens:auto;background:transparent;border:0;border-bottom:1px solid #E2E7EE;padding:15px 16px 15px 0;vertical-align:top;font-size:15px;line-height:1.55;font-weight:500;color:#0D2C4A;\"><strong>Production halls and workshops:<\/strong><\/td><td style=\"overflow-wrap:anywhere;hyphens:auto;background:transparent;border:0;border-bottom:1px solid #E2E7EE;padding:15px 16px 15px 0;vertical-align:top;font-size:15px;line-height:1.55;color:#54687C;\">300 to 500 lux, high-bay luminaires require high luminous intensity<\/td><\/tr><tr style=\"background:transparent;\"><td style=\"overflow-wrap:anywhere;hyphens:auto;background:transparent;border:0;border-bottom:1px solid #E2E7EE;padding:15px 16px 15px 0;vertical-align:top;font-size:15px;line-height:1.55;font-weight:500;color:#0D2C4A;\"><strong>Precision work and quality control:<\/strong><\/td><td style=\"overflow-wrap:anywhere;hyphens:auto;background:transparent;border:0;border-bottom:1px solid #E2E7EE;padding:15px 16px 15px 0;vertical-align:top;font-size:15px;line-height:1.55;color:#54687C;\">750 lux or more, with emphasis on even distribution<\/td><\/tr><tr style=\"background:transparent;\"><td style=\"overflow-wrap:anywhere;hyphens:auto;background:transparent;border:0;border-bottom:1px solid #E2E7EE;padding:15px 16px 15px 0;vertical-align:top;font-size:15px;line-height:1.55;font-weight:500;color:#0D2C4A;\"><strong>Outdoor areas and port locations:<\/strong><\/td><td style=\"overflow-wrap:anywhere;hyphens:auto;background:transparent;border:0;border-bottom:1px solid #E2E7EE;padding:15px 16px 15px 0;vertical-align:top;font-size:15px;line-height:1.55;color:#54687C;\">50 to 200 lux depending on activity, high brightness needed due to large lighting distances<\/td><\/tr><tr style=\"background:transparent;\"><td style=\"overflow-wrap:anywhere;hyphens:auto;background:transparent;border:0;border-bottom:1px solid #E2E7EE;padding:15px 16px 15px 0;vertical-align:top;font-size:15px;line-height:1.55;font-weight:500;color:#0D2C4A;\"><strong>Crane operations and working at height<\/strong><\/td><td style=\"overflow-wrap:anywhere;hyphens:auto;background:transparent;border:0;border-bottom:1px solid #E2E7EE;padding:15px 16px 15px 0;vertical-align:top;font-size:15px;line-height:1.55;color:#54687C;\">Specific high-brightness bundles aimed at the work area<\/td><\/tr><\/tbody><\/table><figcaption style=\"padding-top:12px;font-size:14px;line-height:1.5;color:#5E7288;font-style:normal;\">The requirement per task is set out in NEN-EN 12464-1:2021 for indoor and NEN-EN 12464-2:2024 for outdoor work places. Outdoor values are considerably lower than indoor values.<\/figcaption><\/figure>\n\n\n<p class=\"wp-block-paragraph\">For complex environments where large areas and varying working heights converge, a professional lighting design is essential to determine the correct illuminance per zone.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">How do you measure the light intensity in an industrial space?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Luminance itself is measured with a goniophotometer, a specialized laboratory device that records the light intensity of a luminaire in all directions. In practice, however, on the workplace, you measure illuminance (lux), not luminous intensity (candela) directly,for this, you use a lux meter.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A workplace measurement proceeds as follows: position the light meter at working surface height (standard 0.85 meters above the floor) at multiple measurement points distributed across the room. By comparing the measured lux values with the required standards and analyzing the differences between them, you assess whether the lighting installation provides sufficient and uniform illumination.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Modern lighting software allows for simulations to determine the required light output per luminaire to achieve desired lux levels on the work floor. This prevents installations from failing to meet requirements after the fact, which can avoid costly adjustments on large industrial projects.<\/p>\n\n\n\n\n<div style=\"background:#041E34;border-radius:8px;padding:32px 36px;margin:40px 0 44px;\"><p style=\"margin:0 0 10px;font-family:Sora,system-ui,sans-serif;font-size:13px;line-height:1.4;font-weight:500;letter-spacing:1.8px;text-transform:uppercase;color:#7FA9CF;\">Lighting calculation<\/p><p style=\"margin:0 0 12px;font-family:Sora,system-ui,sans-serif;font-size:26px;line-height:1.25;font-weight:500;letter-spacing:-0.6px;color:#FFFFFF;\">We calculate with the measured light distribution of the luminaire<\/p><p style=\"margin:0 0 24px;font-size:16px;line-height:1.6;color:#A9C6E2;\">The luminous intensity distribution of our luminaires has been measured and is available as an LDT file. We use it in DIALux to calculate, position by position, what reaches the floor or the site: illuminance, uniformity and glare. You receive the report, even if you do not buy from us afterwards.<\/p><p style=\"margin:0;\"><a href=\"#jelfooterintake\" data-item-section=\"cta-midden\" style=\"display:inline-flex;align-items:center;min-height:46px;padding:0 24px;border-radius:4px;background:#0E7AC9;color:#FFFFFF;font-family:Sora,system-ui,sans-serif;font-size:16px;font-weight:500;line-height:1.2;text-decoration:none;\">Request a lighting calculation<\/a><\/p><p style=\"margin:16px 0 0;font-size:14px;line-height:1.5;color:#7FA9CF;\">Free of charge and without obligation \u00b7 Response within 1 working day from an engineer<\/p><\/div>\n\n\n<h2 class=\"wp-block-heading\">The consequences of incorrect light intensity in the workplace are:\n\n*   **Eye strain and fatigue:** Too little or too much light can cause discomfort, dryness, headaches, and blurred vision.\n*   **Reduced productivity and performance:** Poor lighting can make it difficult to see details, increasing errors and slowing down work.\n*   **Increased risk of accidents:** Insufficient lighting can lead to tripping hazards and difficulty navigating the workspace.\n*   **Sleep disturbances:** Exposure to incorrect light, especially blue light at the wrong times, can disrupt the body's natural sleep-wake cycle.\n*   **Mood and well-being:** Inadequate or harsh lighting can contribute to feelings of stress, irritability, and general discomfort.\n*   **Damage to vision over time:** Chronic exposure to improper lighting can potentially contribute to long-term vision problems.<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Both too low and too high light levels in the wrong place cause problems that go beyond discomfort. The consequences directly affect the safety, productivity, and health of employees.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">By <strong>too low brightness<\/strong> Employees see details less clearly, react more slowly to dangerous situations, and make more mistakes. This is particularly risky with machine operations, crane operation, or working at heights. Fatigue and headaches are common complaints with structurally insufficient lighting.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">By <strong>excessive brightness or incorrectly aimed beams<\/strong> This causes glare. Direct or reflected glare disrupts vision and can lead to serious workplace accidents. This risk is particularly high in environments with shiny surfaces, water, or metal.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Additionally, an incorrect lighting installation has economic consequences: luminaires that provide too little light are replaced or supplemented, leading to higher costs. Over-dimensioned luminaires unnecessarily consume energy. A good lighting design based on the correct illuminance prevents both pitfalls.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Which factors influence the effective luminous intensity of an LED luminaire?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The specifications on a datasheet don't tell the whole story. Various technical and environmental factors determine how much light actually reaches the workplace.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The main factors are:<\/p>\n\n\n<div style=\"margin:28px 0 36px;\"><p style=\"margin:0 0 10px;font-family:Sora,system-ui,sans-serif;font-size:13px;line-height:1.4;font-weight:500;letter-spacing:1.8px;text-transform:uppercase;color:#5E7288;\">What determines the effective luminous intensity<\/p><div style=\"border-top:1px solid #0D2C4A;\"><div style=\"padding:14px 0;border-bottom:1px solid #E2E7EE;font-size:16px;line-height:1.6;color:#54687C;\"><strong style=\"font-weight:600;color:#0D2C4A;\">Optics and beam shape:<\/strong> The lens or reflector determines how the light is bundled. A narrow beam provides high intensity over a small angle; a wide beam spreads light over a larger surface with lower intensity per point.<\/div><div style=\"padding:14px 0;border-bottom:1px solid #E2E7EE;font-size:16px;line-height:1.6;color:#54687C;\"><strong style=\"font-weight:600;color:#0D2C4A;\">Temperature:<\/strong> LED chips perform less well at high ambient temperatures. In hot industrial environments, light output can significantly decrease if the luminaire is not thermally well-designed.<\/div><div style=\"padding:14px 0;border-bottom:1px solid #E2E7EE;font-size:16px;line-height:1.6;color:#54687C;\"><strong style=\"font-weight:600;color:#0D2C4A;\">Pollution and light transmittance:<\/strong> Dust, grease, and condensation on the luminaire cover reduce effective light transmission. Luminaires with a high IP rating maintain their performance better in dirty or humid environments. More about IP ratings can be found on the page about <a href=\"https:\/\/jelproducts.nl\/en\/ip-rating\/\">IP and IK ratings<\/a>.<\/div><div style=\"padding:14px 0;border-bottom:1px solid #E2E7EE;font-size:16px;line-height:1.6;color:#54687C;\"><strong style=\"font-weight:600;color:#0D2C4A;\">Light depreciation over time<\/strong> LED lighting gradually loses light output as it ages. Quality luminaires retain a higher percentage of their initial brightness over a longer period (expressed as an L80 or L90 value).<\/div><div style=\"padding:14px 0;border-bottom:1px solid #E2E7EE;font-size:16px;line-height:1.6;color:#54687C;\"><strong style=\"font-weight:600;color:#0D2C4A;\">Mounting height and angle:<\/strong> The higher the luminaire is mounted, the more light intensity is needed to achieve the same lux value on the floor. The mounting angle also determines where the peak of the light beam lands.<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\">For applications in extreme environments, such as high temperatures or aggressive chemical exposure, choosing a luminaire specifically developed for those conditions is crucial for long-term performance.<\/p>\n\n\n\n\n<div style=\"background:#F5F6F8;border-radius:8px;padding:24px;margin:36px 0 40px;\"><p style=\"margin:0 0 10px;font-family:Sora,system-ui,sans-serif;font-size:13px;line-height:1.4;font-weight:500;letter-spacing:1.8px;text-transform:uppercase;color:#5E7288;\">Luminaires for high mounting positions<\/p><div style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(200px,1fr));gap:16px;margin-top:14px;\"><a href=\"https:\/\/jelproducts.nl\/en\/products\/shark\/\" data-item-section=\"productkaart\" style=\"display:flex;flex-direction:column;background:#FFFFFF;border-radius:8px;overflow:hidden;text-decoration:none;color:#0D2C4A;\"><span style=\"position:relative;display:block;aspect-ratio:4\/3;overflow:hidden;background:#EEF1F5;\"><img decoding=\"async\" src=\"https:\/\/jelproducts.nl\/wp-content\/uploads\/2026\/03\/DCbright-Shark-Heavy-Licht-en-compacte-industrieel-en-robuuste-LED-Floodlight-6-1-1024x768.webp\" alt=\"Product rendering of the Shark compact, rugged industrial floodlight\" loading=\"lazy\" style=\"position:absolute;top:0;left:0;display:block;width:100%;height:100%;object-fit:contain;padding:14px;box-sizing:border-box;margin:0;\"><\/span><span style=\"display:flex;flex-direction:column;gap:6px;padding:16px 18px 18px;flex:1;\"><span style=\"font-family:Sora,system-ui,sans-serif;font-size:20px;line-height:1.3;font-weight:500;letter-spacing:-0.3px;color:#0D2C4A;\">Shark<\/span><span style=\"font-size:14px;line-height:1.5;color:#54687C;\">Choice of narrow and wide optics<\/span><span style=\"margin-top:6px;padding-top:10px;border-top:1px solid #E2E7EE;font-size:14px;line-height:1.65;color:#54687C;font-variant-numeric:tabular-nums;\">50,000 lm at 320 W<br>Optics 14 to 69\u00b0 and 14 \u00d7 46\u00b0<br>IP66\/67\/68\/69K, IK10<\/span><span style=\"margin-top:auto;padding-top:12px;font-family:Sora,system-ui,sans-serif;font-size:15px;font-weight:500;color:#064B87;\">View the Shark\u00a0\u2192<\/span><\/span><\/a><a href=\"https:\/\/jelproducts.nl\/en\/products\/orca\/\" data-item-section=\"productkaart\" style=\"display:flex;flex-direction:column;background:#FFFFFF;border-radius:8px;overflow:hidden;text-decoration:none;color:#0D2C4A;\"><span style=\"position:relative;display:block;aspect-ratio:4\/3;overflow:hidden;background:#EEF1F5;\"><img decoding=\"async\" src=\"https:\/\/jelproducts.nl\/wp-content\/uploads\/2026\/07\/Samenstelling-van-alle-DCbright-Orca-modellen-1024x1024.webp\" alt=\"Overview of all DCbright and Orca models\" loading=\"lazy\" style=\"position:absolute;top:0;left:0;display:block;width:100%;height:100%;object-fit:contain;padding:14px;box-sizing:border-box;margin:0;\"><\/span><span style=\"display:flex;flex-direction:column;gap:6px;padding:16px 18px 18px;flex:1;\"><span style=\"font-family:Sora,system-ui,sans-serif;font-size:20px;line-height:1.3;font-weight:500;letter-spacing:-0.3px;color:#0D2C4A;\">Orca<\/span><span style=\"font-size:14px;line-height:1.5;color:#54687C;\">For high masts and large sites<\/span><span style=\"margin-top:6px;padding-top:10px;border-top:1px solid #E2E7EE;font-size:14px;line-height:1.65;color:#54687C;font-variant-numeric:tabular-nums;\">111,300 lm at 800 W<br>IP66\/67\/68\/69K, IK10<br>6 G vibration (IEC 60068-2-6)<\/span><span style=\"margin-top:auto;padding-top:12px;font-family:Sora,system-ui,sans-serif;font-size:15px;font-weight:500;color:#064B87;\">View the Orca\u00a0\u2192<\/span><\/span><\/a><a href=\"https:\/\/jelproducts.nl\/en\/products\/darklicht-m\/\" data-item-section=\"productkaart\" style=\"display:flex;flex-direction:column;background:#FFFFFF;border-radius:8px;overflow:hidden;text-decoration:none;color:#0D2C4A;\"><span style=\"position:relative;display:block;aspect-ratio:4\/3;overflow:hidden;background:#EEF1F5;\"><img decoding=\"async\" src=\"https:\/\/jelproducts.nl\/wp-content\/uploads\/2026\/04\/DCbright-DarkLicht-M150-Full-LED-cutoff-floodlight-7-1-1024x768.webp\" alt=\"Product rendering of the DarkLicht M150 full-cut-off floodlight\" loading=\"lazy\" style=\"position:absolute;top:0;left:0;display:block;width:100%;height:100%;object-fit:contain;padding:14px;box-sizing:border-box;margin:0;\"><\/span><span style=\"display:flex;flex-direction:column;gap:6px;padding:16px 18px 18px;flex:1;\"><span style=\"font-family:Sora,system-ui,sans-serif;font-size:20px;line-height:1.3;font-weight:500;letter-spacing:-0.3px;color:#0D2C4A;\">DarkLicht M<\/span><span style=\"font-size:14px;line-height:1.5;color:#54687C;\">Full cut-off against glare<\/span><span style=\"margin-top:6px;padding-top:10px;border-top:1px solid #E2E7EE;font-size:14px;line-height:1.65;color:#54687C;font-variant-numeric:tabular-nums;\">51,300 lm at 300 W<br>Cut-off 63 to 75\u00b0<br>IP66\/67\/68\/69K, IK08<\/span><span style=\"margin-top:auto;padding-top:12px;font-family:Sora,system-ui,sans-serif;font-size:15px;font-weight:500;color:#064B87;\">View the DarkLicht M\u00a0\u2192<\/span><\/span><\/a><\/div><\/div>\n\n\n<h2 class=\"wp-block-heading\">Practical example: DFDS Vlaardingen<\/h2>\n\n\n<div style=\"margin:36px 0 40px;\"><img decoding=\"async\" src=\"https:\/\/jelproducts.nl\/wp-content\/uploads\/2026\/05\/Verlichting-van-terminal-DFDS-Vlaardingen-_-DarkLicht-_-JEL-Products-1-scaled-1-1024x665.webp\" alt=\"Aerial view of the illuminated DFDS terminal in Vlaardingen with DarkLicht at night\" loading=\"lazy\" style=\"display:block;width:100%;height:auto;aspect-ratio:3\/2;object-fit:cover;object-position:50% 50%;border-radius:8px;box-shadow:0 8px 30px rgba(4,30,52,.18);margin:0;\"><div style=\"margin-top:24px;\"><p style=\"margin:0 0 10px;font-family:Sora,system-ui,sans-serif;font-size:13px;line-height:1.4;font-weight:500;letter-spacing:1.8px;text-transform:uppercase;color:#0E7AC9;\">Project \u00b7 Ports and terminals<\/p><p style=\"margin:0 0 10px;font-family:Sora,system-ui,sans-serif;font-size:24px;line-height:1.25;font-weight:500;letter-spacing:-0.5px;color:#0D2C4A;\">High-mast terminal lighting at DFDS Seaways in Vlaardingen<\/p><p style=\"margin:0;font-size:16px;line-height:1.6;color:#54687C;\">34 masts of 30 metres with DarkLicht, across the entire terminal site on the waterfront. The beam is matched per mast to the mounting height and the geometry of the site.<\/p><\/div><div style=\"margin-top:18px;border-bottom:1px solid #E2E7EE;\"><div style=\"display:grid;grid-template-columns:minmax(0,170px) minmax(0,1fr);column-gap:24px;align-items:baseline;padding:14px 0;border-top:1px solid #E2E7EE;\"><p style=\"margin:0;font-family:Sora,system-ui,sans-serif;font-size:28px;line-height:1.1;font-weight:600;letter-spacing:-1px;color:#0D2C4A;font-variant-numeric:tabular-nums;\">34<\/p><p style=\"margin:0;font-size:15px;line-height:1.45;color:#54687C;\">30-meter light masts<\/p><\/div><div style=\"display:grid;grid-template-columns:minmax(0,170px) minmax(0,1fr);column-gap:24px;align-items:baseline;padding:14px 0;border-top:1px solid #E2E7EE;\"><p style=\"margin:0;font-family:Sora,system-ui,sans-serif;font-size:28px;line-height:1.1;font-weight:600;letter-spacing:-1px;color:#0D2C4A;font-variant-numeric:tabular-nums;\"><span style=\"box-shadow:inset 0 -0.38em 0 #FFE9BD;\">50 lux<\/span><\/p><p style=\"margin:0;font-size:15px;line-height:1.45;color:#54687C;\">average across the site<\/p><\/div><div style=\"display:grid;grid-template-columns:minmax(0,170px) minmax(0,1fr);column-gap:24px;align-items:baseline;padding:14px 0;border-top:1px solid #E2E7EE;\"><p style=\"margin:0;font-family:Sora,system-ui,sans-serif;font-size:28px;line-height:1.1;font-weight:600;letter-spacing:-1px;color:#0D2C4A;font-variant-numeric:tabular-nums;\">0,45<\/p><p style=\"margin:0;font-size:15px;line-height:1.45;color:#54687C;\">uniformity U0<\/p><\/div><\/div><p style=\"margin:16px 0 0;\"><a href=\"https:\/\/jelproducts.nl\/en\/projects\/dfds-seaways-vlaardingen-terminal-lighting\/\" data-item-section=\"projectkaart\" style=\"font-family:Sora,system-ui,sans-serif;font-size:16px;font-weight:500;color:#064B87;text-decoration:none;\">View the DFDS project\u00a0\u2192<\/a><\/p><\/div>\n\n\n<p class=\"wp-block-paragraph\">At the DFDS port terminal in Vlaardingen, which operates 24\/7, JEL handled the lighting design and the installation of new terminal lighting on 34 lighting masts of 30 metres, with a total of around 180 DarkLicht DL1 and DL2 luminaires. The biggest technical challenge was the mast spacing of 145 metres, around five times the mast height. In addition, the terminal borders homes and residential towers, so glare and light pollution towards the residential area had to be prevented. The result is an average of 50 lux on the site with a uniformity of up to 0.45.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">With such a ratio between mast height and mast spacing, the luminous intensity in the right direction determines the result more than the total luminous flux of a luminaire. The light has to reach far across the site at a shallow angle, otherwise dark zones and hard shadows appear between the masts. Precisely controlled optics direct the luminous intensity to those distant points and keep it away from the facades of the homes. Only the distribution of luminous intensity across the various directions shows whether a design achieves the required level and uniformity.<\/p>\n\n\n<div style=\"margin:36px 0 40px;border-top:1px solid #0D2C4A;padding-top:16px;\"><p style=\"margin:0 0 10px;font-family:Sora,system-ui,sans-serif;font-size:13px;line-height:1.4;font-weight:500;letter-spacing:1.8px;text-transform:uppercase;color:#5E7288;\">Further reading<\/p><ul style=\"list-style:none;margin:4px 0 0;padding:0;\"><li style=\"margin:0;padding:11px 0;border-bottom:1px solid #E2E7EE;\"><a href=\"https:\/\/jelproducts.nl\/en\/luminous-flux-what-you-need-to-know\/\" style=\"font-family:Sora,system-ui,sans-serif;font-size:16px;font-weight:500;color:#064B87;text-decoration:none;\">Luminous flux and luminous intensity\u00a0\u2192<\/a><\/li><li style=\"margin:0;padding:11px 0;border-bottom:1px solid #E2E7EE;\"><a href=\"https:\/\/jelproducts.nl\/en\/light-pollution\/\" style=\"font-family:Sora,system-ui,sans-serif;font-size:16px;font-weight:500;color:#064B87;text-decoration:none;\">Light pollution and full cut-off\u00a0\u2192<\/a><\/li><li style=\"margin:0;padding:11px 0;border-bottom:1px solid #E2E7EE;\"><a href=\"https:\/\/jelproducts.nl\/en\/lb-values-lifetime\/\" style=\"font-family:Sora,system-ui,sans-serif;font-size:16px;font-weight:500;color:#064B87;text-decoration:none;\">LB values and service life\u00a0\u2192<\/a><\/li><li style=\"margin:0;padding:11px 0;border-bottom:1px solid #E2E7EE;\"><a href=\"https:\/\/jelproducts.nl\/en\/data-sheets\/\" style=\"font-family:Sora,system-ui,sans-serif;font-size:16px;font-weight:500;color:#064B87;text-decoration:none;\">Datasheets and photometric files\u00a0\u2192<\/a><\/li><\/ul><\/div>\n\n\n<h2 class=\"wp-block-heading\">How JEL Products Helps with Light Intensity in Industrial Environments<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Choosing the right light intensity for an industrial environment is not a one-size-fits-all solution. It requires an understanding of the specific work environment, mounting heights, activities on the shop floor, and applicable standards. JEL Products supports technical decision-makers and project managers at every stage of this process:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n <li>Professional lighting design based on your specific situation and standards<\/li>\n <li>Selection of luminaires with the correct beam shape and light intensity for the application<\/li>\n <li>Calculations and simulations that provide advance insight into the expected lux values<\/li>\n <li>Luminaires designed for extreme conditions, from high temperatures to corrosive environments<\/li>\n <li>Guidance from engineering to installation and commissioning<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Whether it's a production hall, a port terminal, or an outdoor location with harsh conditions, there's always a solution that meets your organization's technical and operational requirements. Feel free to contact us for a no-obligation consultation via <a href=\"https:\/\/jelproducts.nl\/en\/contact\/\">contact page<\/a>.<\/p>","protected":false},"excerpt":{"rendered":"<p>Incorrect brightness costs you safety and money, discover what candela means for your industrial installation.<\/p>","protected":false},"author":1,"featured_media":36550,"template":"","categories":[1],"tags":[],"class_list":["post-34259","blog","type-blog","status-publish","has-post-thumbnail","hentry","category-uncategorized"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.7 (Yoast SEO v28.7) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Wat is lichtsterkte en waarom is het belangrijk bij industri\u00eble verlichting? | JEL Products<\/title>\n<meta name=\"description\" content=\"Lichtsterkte in candela bepaalt of industri\u00eble verlichting effectief en veilig is. Ontdek normen, meetmethoden en hoe u de juiste keuze maakt.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/jelproducts.nl\/en\/blog\/what-is-luminous-intensity-and-why-is-it-important-in-industrial-lighting\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Wat is lichtsterkte en waarom is het belangrijk bij industri\u00eble verlichting?\" \/>\n<meta property=\"og:description\" content=\"Lichtsterkte in candela bepaalt of industri\u00eble verlichting effectief en veilig is. Ontdek normen, meetmethoden en hoe u de juiste keuze maakt.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/jelproducts.nl\/en\/blog\/what-is-luminous-intensity-and-why-is-it-important-in-industrial-lighting\/\" \/>\n<meta property=\"og:site_name\" content=\"JEL Products\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-25T18:31:14+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/jelproducts.nl\/wp-content\/uploads\/2026\/07\/SEO-_-Algemeen-JEL-Products.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"1000\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"9 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/jelproducts.nl\\\/nl\\\/blog\\\/wat-is-lichtsterkte-en-waarom-is-het-belangrijk-bij-industriele-verlichting\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/jelproducts.nl\\\/nl\\\/blog\\\/wat-is-lichtsterkte-en-waarom-is-het-belangrijk-bij-industriele-verlichting\\\/\"},\"author\":{\"name\":\"Lucas de Graaf, BSc\",\"@id\":\"https:\\\/\\\/jelproducts.nl\\\/en\\\/#\\\/schema\\\/person\\\/2c07b1a0a513f8b8a5dc9e1540754f39\"},\"headline\":\"Wat is lichtsterkte en waarom is het belangrijk bij industri\u00eble verlichting?\",\"datePublished\":\"2026-08-02T08:00:00+00:00\",\"dateModified\":\"2026-09-25T18:31:14+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/jelproducts.nl\\\/nl\\\/blog\\\/wat-is-lichtsterkte-en-waarom-is-het-belangrijk-bij-industriele-verlichting\\\/\"},\"wordCount\":1750,\"publisher\":{\"@id\":\"https:\\\/\\\/jelproducts.nl\\\/en\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/jelproducts.nl\\\/nl\\\/blog\\\/wat-is-lichtsterkte-en-waarom-is-het-belangrijk-bij-industriele-verlichting\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/jelproducts.nl\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/SEO-_-Algemeen-JEL-Products.webp\",\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/jelproducts.nl\\\/nl\\\/blog\\\/wat-is-lichtsterkte-en-waarom-is-het-belangrijk-bij-industriele-verlichting\\\/\",\"url\":\"https:\\\/\\\/jelproducts.nl\\\/en\\\/blog\\\/what-is-luminous-intensity-and-why-is-it-important-in-industrial-lighting\\\/\",\"name\":\"Wat is lichtsterkte en waarom is het belangrijk bij industri\u00eble verlichting? | JEL Products\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/jelproducts.nl\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/jelproducts.nl\\\/nl\\\/blog\\\/wat-is-lichtsterkte-en-waarom-is-het-belangrijk-bij-industriele-verlichting\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/jelproducts.nl\\\/nl\\\/blog\\\/wat-is-lichtsterkte-en-waarom-is-het-belangrijk-bij-industriele-verlichting\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/jelproducts.nl\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/SEO-_-Algemeen-JEL-Products.webp\",\"datePublished\":\"2026-08-02T08:00:00+00:00\",\"dateModified\":\"2026-09-25T18:31:14+00:00\",\"description\":\"Lichtsterkte in candela bepaalt of industri\u00eble verlichting effectief en veilig is. Ontdek normen, meetmethoden en hoe u de juiste keuze maakt.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/jelproducts.nl\\\/nl\\\/blog\\\/wat-is-lichtsterkte-en-waarom-is-het-belangrijk-bij-industriele-verlichting\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/jelproducts.nl\\\/nl\\\/blog\\\/wat-is-lichtsterkte-en-waarom-is-het-belangrijk-bij-industriele-verlichting\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/jelproducts.nl\\\/nl\\\/blog\\\/wat-is-lichtsterkte-en-waarom-is-het-belangrijk-bij-industriele-verlichting\\\/#primaryimage\",\"url\":\"https:\\\/\\\/jelproducts.nl\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/SEO-_-Algemeen-JEL-Products.webp\",\"contentUrl\":\"https:\\\/\\\/jelproducts.nl\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/SEO-_-Algemeen-JEL-Products.webp\",\"width\":1000,\"height\":1000,\"caption\":\"Logo van JEL Products\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/jelproducts.nl\\\/nl\\\/blog\\\/wat-is-lichtsterkte-en-waarom-is-het-belangrijk-bij-industriele-verlichting\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/jelproducts.nl\\\/nl\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"blogs\",\"item\":\"https:\\\/\\\/jelproducts.nl\\\/nl\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Wat is lichtsterkte en waarom is het belangrijk bij industri\u00eble verlichting?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/jelproducts.nl\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/jelproducts.nl\\\/en\\\/\",\"name\":\"JEL Products\",\"description\":\"Verlichting voor extreme omstandigheden\",\"publisher\":{\"@id\":\"https:\\\/\\\/jelproducts.nl\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/jelproducts.nl\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/jelproducts.nl\\\/en\\\/#organization\",\"name\":\"JEL Products\",\"alternateName\":[\"JEL\",\"JELproducts\",\"JEL Products B.V.\"],\"url\":\"https:\\\/\\\/jelproducts.nl\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/jelproducts.nl\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/jelproducts.nl\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/logo.webp\",\"contentUrl\":\"https:\\\/\\\/jelproducts.nl\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/logo.webp\",\"width\":1000,\"height\":1000,\"caption\":\"JEL Products\"},\"image\":{\"@id\":\"https:\\\/\\\/jelproducts.nl\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/jelproducts\\\/\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCCBEGfbI72RFq71R7fOn40w\"],\"description\":\"JEL Products is een Nederlandse specialist in industri\u00eble LED-verlichting voor zware en corrosieve omstandigheden. Wij leveren verlichtingssystemen voor havens en terminals, offshore en maritieme operaties, kranen, zware industrie, bouw en infrastructuur, en combineren lichtadvies, engineering, levering en installatieondersteuning in \u00e9\u00e9n traject. Onder de merken DCbright en DarkLicht ontwikkelen wij armaturen die bestand zijn tegen zoutbelasting, trillingen, hoge temperaturen en impact, met aandacht voor het beperken van lichthinder.\",\"email\":\"info@jelproducts.nl\",\"telephone\":\"+31337859809\",\"legalName\":\"JEL Products B.V.\",\"foundingDate\":\"2019-11\",\"vatID\":\"NL868734743B01\",\"taxID\":\"98987615\",\"duns\":\"47-366-4614\",\"numberOfEmployees\":{\"@type\":\"QuantitativeValue\",\"minValue\":\"1\",\"maxValue\":\"10\"},\"publishingPrinciples\":\"https:\\\/\\\/jelproducts.nl\\\/nl\\\/onze-keurmerken\\\/\",\"actionableFeedbackPolicy\":\"https:\\\/\\\/jelproducts.nl\\\/nl\\\/privacy\\\/\",\"correctionsPolicy\":\"https:\\\/\\\/jelproducts.nl\\\/nl\\\/disclaimer\\\/\",\"ethicsPolicy\":\"https:\\\/\\\/jelproducts.nl\\\/nl\\\/disclaimer\\\/\",\"diversityPolicy\":\"https:\\\/\\\/jelproducts.nl\\\/nl\\\/onze-keurmerken\\\/\",\"diversityStaffingReport\":\"https:\\\/\\\/jelproducts.nl\\\/nl\\\/disclaimer\\\/\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Amp\u00e8restraat 19E\",\"postalCode\":\"3861 NC\",\"addressLocality\":\"Nijkerk\",\"addressRegion\":\"Gelderland\",\"addressCountry\":\"NL\"},\"contactPoint\":[{\"@type\":\"ContactPoint\",\"contactType\":\"sales\",\"telephone\":\"+31337859809\",\"email\":\"info@jelproducts.nl\",\"availableLanguage\":[\"nl\",\"en\",\"de\",\"fr\",\"es\"],\"areaServed\":\"Worldwide\"}],\"founder\":[{\"@id\":\"https:\\\/\\\/jelproducts.nl\\\/en\\\/#\\\/schema\\\/persoon\\\/jaap-de-graaf\"},{\"@id\":\"https:\\\/\\\/jelproducts.nl\\\/en\\\/#\\\/schema\\\/persoon\\\/lucas-de-graaf\"}],\"memberOf\":[{\"@type\":\"Organization\",\"name\":\"NSVV, Nederlandse Stichting Voor Verlichtingskunde\",\"url\":\"https:\\\/\\\/nsvv.nl\\\/\"},{\"@type\":\"Organization\",\"name\":\"OVLNL\",\"url\":\"https:\\\/\\\/www.ovlnl.nl\\\/\"},{\"@type\":\"Organization\",\"name\":\"Netherlands Maritime Technology\",\"url\":\"https:\\\/\\\/www.maritimetechnology.nl\\\/\"}]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/jelproducts.nl\\\/en\\\/#\\\/schema\\\/person\\\/2c07b1a0a513f8b8a5dc9e1540754f39\",\"name\":\"Lucas de Graaf, BSc\",\"pronouns\":\"hij\\\/hem\",\"description\":\"Lucas de Graaf is oprichter en technisch directeur van JEL Products, een Nederlands bedrijf dat duurzame en doordachte verlichtingsoplossingen levert voor de meest veeleisende industri\u00eble omgevingen, waaronder mijnbouw, verticaal transport, offshore, havens, infrastructuur en bouw. Sinds de oprichting in 2019 richt hij zich op het combineren van hoogwaardige producten (de merken DCBright en DarkLicht) met diepgaand technisch advies, om tot oplossingen te komen die de verwachtingen van klanten overtreffen. Naast zijn werk bij JEL Products is Lucas vicevoorzitter van het Kernteam Outdoor van de NSVV, de Nederlandse Stichting voor Verlichtingskunde. In die rol vertaalt hij praktijkervaring naar technisch onderbouwde en maatschappelijk relevante richtlijnen, met focus op het verminderen van lichthinder, het verbeteren van veiligheid en het ontwikkelen van toekomstbestendige verlichting. Hij studeerde Entrepreneurship &amp; Retail Management aan Hogeschool Windesheim en behaalde een Lean Six Sigma Green Belt.\",\"sameAs\":[\"https:\\\/\\\/www.jelproducts.nl\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/lucas-de-graaf\\\/\",\"https:\\\/\\\/www.youtube.com\\\/@jelproducts\"],\"honorificSuffix\":\"BSc\",\"gender\":\"Male\",\"knowsAbout\":[\"Industri\u00eble buitenverlichting\",\"Terminal- en havenverlichting\",\"Kraanverlichting en verticaal transport\",\"Verlichting bij hoge temperaturen\",\"Lichthinder en duisternis\",\"Lichtberekeningen en DIALux\",\"NEN-EN 12464-2\",\"EN 13201-2\",\"Offshore- en maritieme verlichting\",\"Lichtmasten en terreinverlichting\",\"LED-armaturen en driverlevensduur\"],\"knowsLanguage\":[\"Nederlands\",\"Engels\",\"Duits\"],\"jobTitle\":\"Technisch Directeur\",\"worksFor\":\"JEL Products B.V.\",\"url\":\"https:\\\/\\\/jelproducts.nl\\\/en\\\/overons\\\/lucas-de-graaf\\\/\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/jelproducts.nl\\\/en\\\/#\\\/schema\\\/person\\\/2c07b1a0a513f8b8a5dc9e1540754f39\\\/foto\",\"url\":\"https:\\\/\\\/jelproducts.nl\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/Lucas-de-Graaf-nieuw_v1-jpg.webp\",\"contentUrl\":\"https:\\\/\\\/jelproducts.nl\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/Lucas-de-Graaf-nieuw_v1-jpg.webp\",\"width\":666,\"height\":667,\"caption\":\"Lucas de Graaf, BSc\"}}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"What Is Luminous Intensity, and Why Is It Important in Industrial Lighting? | JEL Products","description":"Luminous intensity in candela determines whether industrial lighting is effective and safe. Discover standards, measurement methods, and how to make the right choice.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/jelproducts.nl\/en\/blog\/what-is-luminous-intensity-and-why-is-it-important-in-industrial-lighting\/","og_locale":"en_US","og_type":"article","og_title":"Wat is lichtsterkte en waarom is het belangrijk bij industri\u00eble verlichting?","og_description":"Lichtsterkte in candela bepaalt of industri\u00eble verlichting effectief en veilig is. Ontdek normen, meetmethoden en hoe u de juiste keuze maakt.","og_url":"https:\/\/jelproducts.nl\/en\/blog\/what-is-luminous-intensity-and-why-is-it-important-in-industrial-lighting\/","og_site_name":"JEL Products","article_modified_time":"2026-09-25T18:31:14+00:00","og_image":[{"width":1000,"height":1000,"url":"https:\/\/jelproducts.nl\/wp-content\/uploads\/2026\/07\/SEO-_-Algemeen-JEL-Products.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"9 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/jelproducts.nl\/nl\/blog\/wat-is-lichtsterkte-en-waarom-is-het-belangrijk-bij-industriele-verlichting\/#article","isPartOf":{"@id":"https:\/\/jelproducts.nl\/nl\/blog\/wat-is-lichtsterkte-en-waarom-is-het-belangrijk-bij-industriele-verlichting\/"},"author":{"name":"Lucas de Graaf, BSc","@id":"https:\/\/jelproducts.nl\/en\/#\/schema\/person\/2c07b1a0a513f8b8a5dc9e1540754f39"},"headline":"Wat is lichtsterkte en waarom is het belangrijk bij industri\u00eble verlichting?","datePublished":"2026-08-02T08:00:00+00:00","dateModified":"2026-09-25T18:31:14+00:00","mainEntityOfPage":{"@id":"https:\/\/jelproducts.nl\/nl\/blog\/wat-is-lichtsterkte-en-waarom-is-het-belangrijk-bij-industriele-verlichting\/"},"wordCount":1750,"publisher":{"@id":"https:\/\/jelproducts.nl\/en\/#organization"},"image":{"@id":"https:\/\/jelproducts.nl\/nl\/blog\/wat-is-lichtsterkte-en-waarom-is-het-belangrijk-bij-industriele-verlichting\/#primaryimage"},"thumbnailUrl":"https:\/\/jelproducts.nl\/wp-content\/uploads\/2026\/07\/SEO-_-Algemeen-JEL-Products.webp","inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/jelproducts.nl\/nl\/blog\/wat-is-lichtsterkte-en-waarom-is-het-belangrijk-bij-industriele-verlichting\/","url":"https:\/\/jelproducts.nl\/en\/blog\/what-is-luminous-intensity-and-why-is-it-important-in-industrial-lighting\/","name":"What Is Luminous Intensity, and Why Is It Important in Industrial Lighting? | JEL Products","isPartOf":{"@id":"https:\/\/jelproducts.nl\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/jelproducts.nl\/nl\/blog\/wat-is-lichtsterkte-en-waarom-is-het-belangrijk-bij-industriele-verlichting\/#primaryimage"},"image":{"@id":"https:\/\/jelproducts.nl\/nl\/blog\/wat-is-lichtsterkte-en-waarom-is-het-belangrijk-bij-industriele-verlichting\/#primaryimage"},"thumbnailUrl":"https:\/\/jelproducts.nl\/wp-content\/uploads\/2026\/07\/SEO-_-Algemeen-JEL-Products.webp","datePublished":"2026-08-02T08:00:00+00:00","dateModified":"2026-09-25T18:31:14+00:00","description":"Luminous intensity in candela determines whether industrial lighting is effective and safe. Discover standards, measurement methods, and how to make the right choice.","breadcrumb":{"@id":"https:\/\/jelproducts.nl\/nl\/blog\/wat-is-lichtsterkte-en-waarom-is-het-belangrijk-bij-industriele-verlichting\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/jelproducts.nl\/nl\/blog\/wat-is-lichtsterkte-en-waarom-is-het-belangrijk-bij-industriele-verlichting\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/jelproducts.nl\/nl\/blog\/wat-is-lichtsterkte-en-waarom-is-het-belangrijk-bij-industriele-verlichting\/#primaryimage","url":"https:\/\/jelproducts.nl\/wp-content\/uploads\/2026\/07\/SEO-_-Algemeen-JEL-Products.webp","contentUrl":"https:\/\/jelproducts.nl\/wp-content\/uploads\/2026\/07\/SEO-_-Algemeen-JEL-Products.webp","width":1000,"height":1000,"caption":"Logo van JEL Products"},{"@type":"BreadcrumbList","@id":"https:\/\/jelproducts.nl\/nl\/blog\/wat-is-lichtsterkte-en-waarom-is-het-belangrijk-bij-industriele-verlichting\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/jelproducts.nl\/nl\/"},{"@type":"ListItem","position":2,"name":"blogs","item":"https:\/\/jelproducts.nl\/nl\/blog\/"},{"@type":"ListItem","position":3,"name":"Wat is lichtsterkte en waarom is het belangrijk bij industri\u00eble verlichting?"}]},{"@type":"WebSite","@id":"https:\/\/jelproducts.nl\/en\/#website","url":"https:\/\/jelproducts.nl\/en\/","name":"JEL Products","description":"Lighting for extreme conditions","publisher":{"@id":"https:\/\/jelproducts.nl\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/jelproducts.nl\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/jelproducts.nl\/en\/#organization","name":"JEL Products","alternateName":["JEL","JELproducts","JEL Products B.V."],"url":"https:\/\/jelproducts.nl\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/jelproducts.nl\/en\/#\/schema\/logo\/image\/","url":"https:\/\/jelproducts.nl\/wp-content\/uploads\/2026\/07\/logo.webp","contentUrl":"https:\/\/jelproducts.nl\/wp-content\/uploads\/2026\/07\/logo.webp","width":1000,"height":1000,"caption":"JEL Products"},"image":{"@id":"https:\/\/jelproducts.nl\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/jelproducts\/","https:\/\/www.youtube.com\/channel\/UCCBEGfbI72RFq71R7fOn40w"],"description":"JEL Products is a Dutch specialist in industrial LED lighting for harsh and corrosive environments. We supply lighting systems for ports and terminals, offshore and maritime operations, cranes, heavy industry, construction, and infrastructure, and combine lighting consultation, engineering, delivery, and installation support into a single process. Under the DCbright and DarkLicht brands, we develop luminaires that are resistant to salt exposure, vibrations, high temperatures, and impact, with a focus on minimizing light pollution.","email":"info@jelproducts.nl","telephone":"+31337859809","legalName":"JEL Products B.V.","foundingDate":"2019-11","vatID":"NL868734743B01","taxID":"98987615","duns":"47-366-4614","numberOfEmployees":{"@type":"QuantitativeValue","minValue":"1","maxValue":"10"},"publishingPrinciples":"https:\/\/jelproducts.nl\/nl\/onze-keurmerken\/","actionableFeedbackPolicy":"https:\/\/jelproducts.nl\/nl\/privacy\/","correctionsPolicy":"https:\/\/jelproducts.nl\/nl\/disclaimer\/","ethicsPolicy":"https:\/\/jelproducts.nl\/nl\/disclaimer\/","diversityPolicy":"https:\/\/jelproducts.nl\/nl\/onze-keurmerken\/","diversityStaffingReport":"https:\/\/jelproducts.nl\/nl\/disclaimer\/","address":{"@type":"PostalAddress","streetAddress":"Amp\u00e8restraat 19E","postalCode":"3861 NC","addressLocality":"Nijkerk","addressRegion":"Gelderland","addressCountry":"NL"},"contactPoint":[{"@type":"ContactPoint","contactType":"sales","telephone":"+31337859809","email":"info@jelproducts.nl","availableLanguage":["nl","en","de","fr","es"],"areaServed":"Worldwide"}],"founder":[{"@id":"https:\/\/jelproducts.nl\/en\/#\/schema\/persoon\/jaap-de-graaf"},{"@id":"https:\/\/jelproducts.nl\/en\/#\/schema\/persoon\/lucas-de-graaf"}],"memberOf":[{"@type":"Organization","name":"NSVV, Nederlandse Stichting Voor Verlichtingskunde","url":"https:\/\/nsvv.nl\/"},{"@type":"Organization","name":"OVLNL","url":"https:\/\/www.ovlnl.nl\/"},{"@type":"Organization","name":"Netherlands Maritime Technology","url":"https:\/\/www.maritimetechnology.nl\/"}]},{"@type":"Person","@id":"https:\/\/jelproducts.nl\/en\/#\/schema\/person\/2c07b1a0a513f8b8a5dc9e1540754f39","name":"Lucas de Graaf, BSc","pronouns":"hij\/hem","description":"Lucas de Graaf is the founder and technical director of JEL Products, a Dutch company that provides sustainable and well-designed lighting solutions for the most demanding industrial environments, including mining, vertical transportation, offshore, ports, infrastructure, and construction. Since its founding in 2019, he has focused on combining high-quality products (the DCBright and DarkLicht brands) with in-depth technical advice to deliver solutions that exceed customer expectations. In addition to his work at JEL Products, Lucas serves as vice-chair of the Outdoor Core Team at the NSVV, the Dutch Foundation for Lighting Science. In that role, he translates practical experience into technically sound and socially relevant guidelines, with a focus on reducing light pollution, improving safety, and developing future-proof lighting. He studied Entrepreneurship &amp; Retail Management at Windesheim University of Applied Sciences and earned a Lean Six Sigma Green Belt.","sameAs":["https:\/\/www.jelproducts.nl","https:\/\/www.linkedin.com\/in\/lucas-de-graaf\/","https:\/\/www.youtube.com\/@jelproducts"],"honorificSuffix":"BSc","gender":"Male","knowsAbout":["Industri\u00eble buitenverlichting","Terminal- en havenverlichting","Kraanverlichting en verticaal transport","Verlichting bij hoge temperaturen","Lichthinder en duisternis","Lichtberekeningen en DIALux","NEN-EN 12464-2","EN 13201-2","Offshore- en maritieme verlichting","Lichtmasten en terreinverlichting","LED-armaturen en driverlevensduur"],"knowsLanguage":["Nederlands","Engels","Duits"],"jobTitle":"Technisch Directeur","worksFor":"JEL Products B.V.","url":"https:\/\/jelproducts.nl\/en\/overons\/lucas-de-graaf\/","image":{"@type":"ImageObject","@id":"https:\/\/jelproducts.nl\/en\/#\/schema\/person\/2c07b1a0a513f8b8a5dc9e1540754f39\/foto","url":"https:\/\/jelproducts.nl\/wp-content\/uploads\/2026\/03\/Lucas-de-Graaf-nieuw_v1-jpg.webp","contentUrl":"https:\/\/jelproducts.nl\/wp-content\/uploads\/2026\/03\/Lucas-de-Graaf-nieuw_v1-jpg.webp","width":666,"height":667,"caption":"Lucas de Graaf, BSc"}}]}},"_links":{"self":[{"href":"https:\/\/jelproducts.nl\/en\/wp-json\/wp\/v2\/blog\/34259","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/jelproducts.nl\/en\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/jelproducts.nl\/en\/wp-json\/wp\/v2\/types\/blog"}],"author":[{"embeddable":true,"href":"https:\/\/jelproducts.nl\/en\/wp-json\/wp\/v2\/users\/1"}],"version-history":[{"count":3,"href":"https:\/\/jelproducts.nl\/en\/wp-json\/wp\/v2\/blog\/34259\/revisions"}],"predecessor-version":[{"id":39016,"href":"https:\/\/jelproducts.nl\/en\/wp-json\/wp\/v2\/blog\/34259\/revisions\/39016"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/jelproducts.nl\/en\/wp-json\/wp\/v2\/media\/36550"}],"wp:attachment":[{"href":"https:\/\/jelproducts.nl\/en\/wp-json\/wp\/v2\/media?parent=34259"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/jelproducts.nl\/en\/wp-json\/wp\/v2\/categories?post=34259"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/jelproducts.nl\/en\/wp-json\/wp\/v2\/tags?post=34259"}],"curies":[{"name":"WP","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}