Blog

What are the risks of overheating lighting in a factory?

Overheated lighting in a factory carries serious risks: from fire hazards and electrical malfunctions to sudden outages at critical moments. Fixtures that become structurally too hot lose their power more quickly, shorten their own lifespan, and in extreme cases can pose a direct safety threat to people and installations. In this article, we answer the most frequently asked questions about industrial lighting overheating, from its causes to solutions.

What dangers arise when the lighting becomes too hot?

If lighting in a factory becomes too hot, multiple hazards arise simultaneously: increased fire risk due to overheated components, accelerated degradation of electrical connections, and sudden failure of luminaires at the moment they are most needed. Especially in environments with flammable materials, dust, or gases, the fire risk from lighting in a factory is not a theoretical risk.

The temperature of a luminaire has a direct impact on the safety of the environment. When the housing or the driver compartment rises above the design temperature, insulating materials can deteriorate more quickly. This increases the risk of short circuits. In the worst case, a spark or heat point could be enough to start a fire, especially in sectors such as the chemical industry, the paper industry or steel mills.

In addition, there is the risk of unexpected outages. A fixture that overheats sometimes automatically switches itself off as a safety measure. In itself, this is a useful function, but when this happens in the middle of a night shift or during a critical production cycle, it has immediate consequences for the safety of employees who suddenly find themselves in the dark.

How does overheating occur in industrial luminaires?

Overheating in industrial luminaires occurs when the heat produced by a light source is not removed quickly enough. This can be caused by a too high ambient temperature, poor ventilation around the luminaire, an incorrectly selected luminaire for the application, or outdated components that have become less efficient.

In LED lighting, the so-called junction temperature plays a central role. This is the temperature in the heart of the LED chip. If it rises too high, the chip’s degradation accelerates and the light output quickly decreases. Therefore, good thermal control, through cooling elements, material selection and fixture design, is not a luxury but a necessity.

Other common causes are:

  • Lighting fixtures designed for office or outdoor applications but used in warm production environments
  • Crystallization of dust on cooling elements, which hinders heat dissipation
  • Infrared radiation from nearby machines or ovens that increase the fixture temperature from the outside
  • Insufficient distance between the luminaire and the heat source
  • Outdated drivers that produce more heat than modern alternatives

What are the consequences of overheating for production downtime and costs?

Overheating of lighting in practice leads to higher maintenance costs, shorter replacement cycles, and in the worst case to unplanned production downtime. When lighting fails prematurely, technicians must replace fixtures in sometimes difficult-to-reach locations, which directly costs production time and personnel resources.

The financial impact is greater than many companies expect. In addition to the direct costs of replacement fixtures and labor, there are the indirect costs: delayed production, increased safety risks during downtime, and the logistical challenge of planning maintenance at height or in hazardous zones. In sectors that operate 24/7, such as ports, terminals, or steel mills, even a brief outage can cause significant financial damage.

Well chosen high-temperature lighting This significantly reduces this risk by preventing thermal overload from occurring structurally, rather than resolving it temporarily.

Which areas in a factory are the most dangerous?

Not every place in a factory has the same lighting requirements. The most risky environments for overheating are locations where high ambient temperatures, direct radiant heat, or limited airflow combine with the need for continuous lighting.

Consider the following situations:

  1. Near furnaces, melting plants or high-temperature furnaces in the steel industry, where ambient temperatures can be structurally above 60 or 80 degrees Celsius
  2. Dry rooms and heat treatment rooms in the paper or food industry, where lighting is exposed to hot air flows
  3. Foundries and blacksmiths, where, in addition to high temperatures, sparks and splatters of molten metal also play a role
  4. Climate chambers with varying temperatures, where condensation and thermal shocks place additional strain on the components
  5. Ceilings and roof structures of production halls, where heat rises and fixtures are constantly exposed to the warmest air in the room

In all these situations, standard lighting simply isn’t suitable. It’s not just a matter of maximum temperature, but also of the duration of exposure and its combination with other factors such as dust, moisture, or chemical fumes.

What specifications should lighting have in high-temperature environments?

Lighting for high-temperature environments must be equipped with at least a high IP rating, a robust thermal design with active or passive cooling, and components that have been tested and certified for the specific temperature range of the application.

Specifically, these are the most relevant specifications to keep in mind:

  • Maximum ambient temperature (Ta): Always check that the value given corresponds to the actual conditions at the installation location.
  • Thermal management: Equipment with aluminum or steel heat sinks and a well-thought-out heat dissipation path perform better than compact enclosures without a cooling surface.
  • IP rating For dusty or humid environments, minimum IP65 is required; for spattering liquids or high-pressure sprayers, IP66 higher is required.
  • Housing material: For corrosive environments, stainless steel or coated aluminum is the better choice over standard aluminum.
  • Infrared resistance: in environments with strong radiant heat, such as near high-temperature furnaces, the luminaire must be resistant to direct IR radiation

For the most extreme applications, such as steel mills with temperatures above 100 degrees Celsius, specially developed high-temperature luminaires are necessary. More information about the requirements in heavy industry with extreme heat helps in making the right choice.

When is it time to replace industrial lighting?

Industrial lighting must be replaced when the light output has noticeably decreased, the fixtures are regularly turning off or restarting, the housing is visibly damaged or discolored, or when the installation is simply no longer designed for the current environmental conditions.

A practical way to assess this is to go through a series of signals:

  1. Light yield is visibly decreasing without the bulbs being replaced: this indicates thermal degradation of the LED chips
  2. The fixtures become extremely hot on the outside, which indicates that the internal temperature is even higher
  3. Frequent malfunctions or restart cycles Indicates thermal protection that is continuously active
  4. Discolorations on the housing or the glass are a sign of prolonged overheating
  5. The luminaires are more than 10 years old and have never been tested at the current ambient temperatures

Do not reactively replace lighting after a failure; instead, proactively replace it based on condition and environmental analysis. In the long run, this ultimately saves more than delaying an investment.

Practical example: VPK Paper

VPK Paper wanted to convert the lighting in its paper mills in Belgium to LED. In and around the paper machine, the temperature can in extreme cases reach +120 °C, with steam development and a very high humidity in the machine itself. After multiple trials with different suppliers, none of the LED solutions tried were successful. One trial was successful, after which JEL Snapper HT 98 Snapper HT luminaires were supplied in AC version, with 35 W per luminaire. The installation provides 100 to 200 lux in the machine.

Overheating is not a theoretical risk in such an environment. Heat shortens the lifespan of the LED and the driver, and steam and moisture find every weak spot in the seal. Each failed trial cost time, money, and trust in the conversion to LED.

Therefore, a fixture that is heat-resistant on paper is only proven when it continues to operate under the actual combination of temperature and humidity. A test on the own premises reduces the risk of having to replace an entire installation again.

Read more about the VPK Paper project

How to JEL Products help with overheating of industrial lighting

JEL Products provides LED lighting solutions that are specifically designed for environments where standard lighting is not sufficient. For situations involving extreme heat, radiant heat, or fluctuating temperatures, it offers JEL Products concrete support on multiple levels:

  • Technical advice on-site: analysis of the actual environmental conditions, including radiant heat, air circulation and temperature peaks
  • Customized product specifications: selection of luminaires that have been tested and suitable for the specific temperature range of the application
  • High-temperature luminaires: Like the Orca HT and HT Barracuda floodlights, designed for temperatures up to +120 degrees Celsius and resistant to direct infrared radiation
  • Lighting Design and Engineering: from the initial calculation to the final installation plan, including positioning for optimal thermal performance
  • Installation and commissioning by a certified team, so that the lighting functions properly immediately under actual conditions
  • Maintenance and replacement advice: Proactive guidance to prevent downtime and maximize the lifespan of the installation

Does your organization operate in an environment where heat, radiation or extreme temperatures are the norm? Then contact us via the JEL Products Contact Page for a free consultation about the right lighting solution for your situation.

Related Articles