Home / Products / Full cut-off floodlights / DarkLicht One, Two, and Three
All lumens on the site, zero above: up to 307,800 lumens from a single luminaire at 171 lm/W, with an adjustable cut-off from 63 to 75 degrees.
A standard floodlight uses lenses and therefore always loses some of its light to glare and scattered light. The DarkLicht uses a patented parabolic reflector that directs the light onto the surface to be illuminated and not beside it. This not only reduces complaints from nearby residents: since no light escapes, you don’t need to generate as much, so you need fewer poles and fewer watts to achieve the same light level.
A response from an engineer within 1 business day. Free lighting calculation with a light pollution assessment.
Titanium Black, with a frame made of 316L stainless steel.
de Three, 1,800 W, 171 lm/W
above the set cut-off
adjustable on-site
six versions, three sizes
IP66 and IP67, IK07 with glass front
up to 10 years with maintenance contract
This luminaire is at its best where a lot of light needs to be cast on the site and nothing is allowed to spill over, because a permit, a guideline, or the neighborhood demands it.
If light pollution plays no role, you are paying for lighting control that you do not need. We prefer to tell you that in advance.
One, Two and Three share the same reflector technology, the same 171 lm/W and the same adjustable cut-off; only the 320 W version is at 160 lm/W. What else differs is the number of reflector modules, and with it the power, length and weight.
The entry-level version with internal driver, for medium-sized grounds, construction sites and sports fields. The only version at 160 lm/W.
DARK01-50K · internal BLD320 · 14.9 kg
Same housing with a higher wattage. Internal driver, so one cable to the luminaire and no separate driver box on the pole.
DARK02-50K · internal TLD400 · 15.0 kg
External driver in a DRB box: lighter on the mast than the 400 W and to be replaced at the base of the mast. Including the driver box, approximately 23 kg for the mast calculation.
DARK03-50K · TLD600 · 14.0 kg
The size mounted on most terminals: enough luminous flux to stretch the mast spacing, and still manageable to lift during maintenance.
DARK04-50K · 24.8 kg
Same housing and weight as the 800 W, with half as much luminous flux again. For port terminals and large sports facilities from high masts.
DARK05-50K · 24.8 kg
One Three replaces multiple conventional floodlights, without a single lumen of stray light. Pay attention to the load-bearing capacity: 35 kg plus wind load.
DL3-1800 · 35.0 kg
At DFDS in Vlaardingen, the switch to DarkLicht resulted in a 53 percent reduction in energy consumption, while the terminal was better lit than before. The aerial photo shows how the reflector works: the area is brightly lit, and the edges are sharp. At P&O Ferries in Europoort, energy consumption dropped by about 66 percent, with thirty new mast structures installed in just two weeks at a terminal that continued to operate as usual.
BUSS Terminal Eemshaven, RKAV Volendam, and the HSB construction site in Hilversum also use the DarkLicht system.
See the projects, the photo gallery and lighting advice and lighting calculation.
lower energy consumption
lower consumption, 30 mast structures
Choose a trim level and the specification list, image, and dimensional drawing will change accordingly. One row of six, no nested tabs.
Version
Order code DARK01-50K · also available in 40K, 30K, 22K, BIC, and PDL
Internal driver, for medium-sized terrains.
| Luminous flux | 51,200 lm |
| Power consumption | 320 W |
| Efficiency | 160 lm/W |
| Cut-off | 63°, 66°, 69°, 72°, 75° cut-off |
| Measured beam angle | 132° beam, 138° field, shielding position |
| Color temperatures | 1700K to 5700K, standard 4000K |
| Color-changeable | 4000K, 2200K and 1700K, switchable during operation |
| CRI (Ra) | > 70, or optionally 80 or 90 |
| Color consistency | 3-step MacAdam |
| Housing | cast aluminum, < 0.08 % copper |
| Surface treatment | conversion layer + 2-layer titanium e-coating |
| Bracket | High tensile strength 316L, −20° to +20° |
| Front | impact-resistant glass; luminaire rated at IK07 |
| Color | Titanium Black, Titanium Grey or Neutral White |
| Dimensions | 365 × 550 × 160 mm |
| Weight | 14.9 kg |
| Lead time | Standard within a week, custom by arrangement |
| Accessories | tower crane frame |
| Voltage range | 180 to 528 VAC |
| Item variants | also in 40K, 30K, 22K, BIC and PDL |
| Current draw | approx. 0.8 A at 380 V, 1.5 A at 220 V |
| Driver | internal BLD320 |
| Driver (type) | BLD320 (320 W) |
| Driver lifespan | ≥ 100,000 hours at Tc 75 °C; ≥ 130,000 hours at Tc 50 °C |
| MTBF driver | ≥ 280,000 hours at Tc 75 °C (MIL-HDBK-217F) |
| Inrush current | 31.2 A peak, T50 1.3 ms at 220 V |
| Luminaires per MCB | B16: 2 · C16: 4 · C25: 7 · D16: 8 |
| Overvoltage | 6 kV line-to-line, 10 kV line-to-ground (IEC 61000-4-5) |
| Dimming | 0–10 V, PWM, and DALI-2 or via NFC |
| Power factor / THD | > 0.95 at 60–100 % load; THD < 15 % |
| IP and IK | IP66 and IP67 / IK07 |
| Operating temperature | −45 to +50 °C |
| LED lifespan | TM-21 L90B05 > 103,500 hours |
| Corrosion class | C5 Industrial and Maritime (ISO 9223) |
| Warranty | 5 years, with maintenance contract up to 10 years |
| Certification | CE, IEC 60598, EN 55015, EN 61547, EMC |
| HS code | 9405500090 |
The entry-level model in the large DarkLicht series, with an internal driver. Designed for medium-sized outdoor areas, construction sites, and sports fields. This is the only model with a luminous efficacy of 160 lm/W; all other models achieve 171 lm/W.
Version
Order code DARK02-50K · also available in 40K, 30K, 22K, and BIC
Internal driver, for medium-sized terrains.
| Luminous flux | 68,400 lm |
| Power consumption | 400 W |
| Efficiency | 171 lm/W |
| Cut-off | 63°, 66°, 69°, 72°, 75° cut-off |
| Measured beam angle | 132° beam, 138° field, shielding position |
| Color temperatures | 1700K to 5700K, standard 4000K |
| Color-changeable | 4000K, 2200K and 1700K, switchable during operation |
| CRI (Ra) | > 70, or optionally 80 or 90 |
| Color consistency | 3-step MacAdam |
| Housing | cast aluminum, < 0.08 % copper |
| Surface treatment | conversion layer + 2-layer titanium e-coating |
| Bracket | High tensile strength 316L, −20° to +20° |
| Front | impact-resistant glass; luminaire rated at IK07 |
| Color | Titanium Black, Titanium Grey or Neutral White |
| Dimensions | 365 × 550 × 160 mm |
| Weight | 15.0 kg |
| Accessories | tower crane frame |
| Voltage range | 180 to 528 VAC |
| Item variants | also in 40K, 30K, 22K and BIC |
| Current draw | approx. 1.1 A at 380 V, 1.8 A at 220 V |
| Driver | internal TLD400 |
| Driver (type) | TLD400 (400 W) |
| Driver lifespan | ≥ 100,000 hours at Tc 75 °C; ≥ 130,000 hours at Tc 50 °C |
| MTBF driver | ≥ 280,000 hours at Tc 75 °C (MIL-HDBK-217F) |
| Inrush current | 64 A peak, T50 400 µs at 220 V |
| Luminaires per MCB | B16: 4 · C16: 5 · C25: 8 · D16: 6 |
| Overvoltage | 6 kV line-to-line, 10 kV line-to-ground (IEC 61000-4-5) |
| Dimming | 0–10 V, PWM, and DALI-2 or via NFC |
| Power factor / THD | > 0.9 at 60–100 % load; THD < 15 % |
| IP and IK | IP66 and IP67 / IK07 |
| Operating temperature | −45 to +50 °C |
| LED lifespan | TM-21 L90B05 > 103,500 hours |
| Corrosion class | C5 Industrial and Maritime (ISO 9223) |
| Warranty | 5 years, with maintenance contract up to 10 years |
| Certification | CE, IEC 60598, EN 55015, EN 61547, EMC |
| HS code | 9405500090 |
Same housing as the 320 W with a higher power output. Internal driver, so one cable to the luminaire and no separate driver box on the pole.
Version
Order code DARK03-50K · also available in 40K, 30K, 22K, and BIC
External driver, also available as 24 volt DC.
| Luminous flux | 102,600 lm |
| Power consumption | 600 W |
| Efficiency | 171 lm/W |
| Cut-off | 63°, 66°, 69°, 72°, 75° cut-off |
| Measured beam angle | 132° beam, 138° field, shielding position |
| Color temperatures | 1700K to 5700K, standard 4000K |
| Color-changeable | 4000K, 2200K and 1700K, switchable during operation |
| CRI (Ra) | > 70, or optionally 80 or 90 |
| Color consistency | 3-step MacAdam |
| Housing | cast aluminum, < 0.08 % copper |
| Surface treatment | conversion layer + 2-layer titanium e-coating |
| Bracket | High tensile strength 316L, −20° to +20° |
| Front | impact-resistant glass; luminaire rated at IK07 |
| Color | Titanium Black, Titanium Grey or Neutral White |
| Dimensions | 365 × 550 × 160 mm |
| Weight | 14.0 kg |
| Accessories | tower crane frame |
| Voltage range | 180 to 528 VAC |
| Item variants | also in 40K, 30K, 22K and BIC |
| Current draw | approx. 1.6 A at 380 V, 2.7 A at 220 V |
| Driver | external TLD600, in DRB driver box |
| Driver (type) | TLD600 (600 W) |
| Driver lifespan | ≥ 100,000 hours at Tc 75 °C; ≥ 130,000 hours at Tc 50 °C |
| MTBF driver | ≥ 320,000 hours at Tc 75 °C (MIL-HDBK-217F) |
| Inrush current | 5.4 A peak, T50 8 ms at 220 V |
| Luminaires per MCB | B16: 3 · C16: 3 · C25: 5 · D16: 4 |
| Overvoltage | 6 kV line-to-line, 10 kV line-to-ground (IEC 61000-4-5) |
| Dimming | 0–10 V, PWM, and DALI-2 or via NFC |
| Power factor / THD | > 0.9 at 60–100 % load; THD < 15 % |
| IP and IK | IP66 and IP67 / IK07 |
| Operating temperature | −45 to +50 °C |
| LED lifespan | TM-21 L90B05 > 103,500 hours |
| Corrosion class | C5 Industrial and Maritime (ISO 9223) |
| Warranty | 5 years, with maintenance contract up to 10 years |
| Certification | CE, IEC 60598, EN 55015, EN 61547, EMC |
| HS code | 9405500090 |
From this wattage onwards, the driver is housed externally in a DRB box. As a result, the luminaire is lighter than the 400W version, despite the higher wattage, and the driver can be replaced at the base of the mast. Also available as a 24-volt direct current version.
Version
Order code DARK04-50K · also available in 40K, 30K, 22K, and BIC
The workhorse for large properties.
| Luminous flux | 136,800 lm |
| Power consumption | 800 W |
| Efficiency | 171 lm/W |
| Cut-off | 63°, 66°, 69°, 72°, 75° cut-off |
| Measured beam angle | 132° beam, 138° field, shielding position |
| Color temperatures | 1700K to 5700K, standard 4000K |
| Color-changeable | 4000K, 2200K and 1700K, switchable during operation |
| CRI (Ra) | > 70, or optionally 80 or 90 |
| Color consistency | 3-step MacAdam |
| Housing | cast aluminum, < 0.08 % copper |
| Surface treatment | conversion layer + 2-layer titanium e-coating |
| Bracket | High tensile strength 316L, −20° to +20° |
| Front | impact-resistant glass; luminaire rated at IK07 |
| Color | Titanium Black, Titanium Grey or Neutral White |
| Dimensions | 635 × 550 × 160 mm |
| Weight | 24.8 kg |
| Accessories | no |
| Voltage range | 180 to 528 VAC |
| Item variants | also in 40K, 30K, 22K and BIC |
| Current draw | approx. 2.2 A at 380 V, 3.7 A at 220 V |
| Driver | external TLD800 |
| Driver (type) | TLD800 (800 W) |
| Driver lifespan | ≥ 100,000 hours at Tc 75 °C; ≥ 130,000 hours at Tc 50 °C |
| MTBF driver | ≥ 320,000 hours at Tc 75 °C (MIL-HDBK-217F) |
| Inrush current | 5.4 A peak, T50 8 ms at 220 V |
| Luminaires per MCB | B16: 2 · C16: 2 · C25: 4 · D16: 3 |
| Overvoltage | 6 kV line-to-line, 10 kV line-to-ground (IEC 61000-4-5) |
| Dimming | 0–10 V, PWM, and DALI-2 or via NFC |
| Power factor / THD | > 0.9 at 60–100 % load; THD < 15 % |
| IP and IK | IP66 and IP67 / IK07 |
| Operating temperature | −45 to +50 °C |
| LED lifespan | TM-21 L90B05 > 103,500 hours |
| Corrosion class | C5 Industrial and Maritime (ISO 9223) |
| Warranty | 5 years, with maintenance contract up to 10 years |
| Certification | CE, IEC 60598, EN 55015, EN 61547, EMC |
| HS code | 9405500090 |
The Two is the size installed on most terminals: enough luminous flux to stretch the pole spacing, and still manageable to lift during maintenance. Like the 400 W One, this version has an internal driver; starting from 1,200 W, the driver is external.
Version
Order code DARK05-50K · also available in 40K, 30K, 22K, and BIC
External driver in DRB-2.
| Luminous flux | 205,200 lm |
| Power consumption | 1,200 W |
| Efficiency | 171 lm/W |
| Cut-off | 63°, 66°, 69°, 72°, 75° cut-off |
| Measured beam angle | 132° beam, 138° field, shielding position |
| Color temperatures | 1700K to 5700K, standard 4000K |
| Color-changeable | 4000K, 2200K and 1700K, switchable during operation |
| CRI (Ra) | > 70, or optionally 80 or 90 |
| Color consistency | 3-step MacAdam |
| Housing | cast aluminum, < 0.08 % copper |
| Surface treatment | conversion layer + 2-layer titanium e-coating |
| Bracket | High tensile strength 316L, −20° to +20° |
| Front | impact-resistant glass; luminaire rated at IK07 |
| Color | Titanium Black, Titanium Grey or Neutral White |
| Dimensions | 635 × 550 × 160 mm |
| Weight | 24.8 kg |
| Accessories | no |
| Voltage range | 180 to 528 VAC |
| Item variants | also in 40K, 30K, 22K and BIC |
| Current draw | approx. 3.2 A at 380 V, 5.5 A at 220 V |
| Driver | external, 2× TLD600 in DRB-2 or on a tray |
| Driver (type) | TLD600 (600 W), 2 per fixture |
| Driver lifespan | ≥ 100,000 hours at Tc 75 °C; ≥ 130,000 hours at Tc 50 °C |
| MTBF driver | ≥ 320,000 hours at Tc 75 °C (MIL-HDBK-217F) |
| Inrush current | 5.4 A peak, T50 8 ms at 220 V, per driver |
| Luminaires per MCB | B16: 1 · C16: 1 · C25: 2 · D16: 2 |
| Overvoltage | 6 kV line-to-line, 10 kV line-to-ground (IEC 61000-4-5) |
| Dimming | 0–10 V, PWM, and DALI-2 or via NFC |
| Power factor / THD | > 0.9 at 60–100 % load; THD < 15 % |
| IP and IK | IP66 and IP67 / IK07 |
| Operating temperature | −45 to +50 °C |
| LED lifespan | TM-21 L90B05 > 103,500 hours |
| Corrosion class | C5 Industrial and Maritime (ISO 9223) |
| Warranty | 5 years, with maintenance contract up to 10 years |
| Certification | CE, IEC 60598, EN 55015, EN 61547, EMC |
| HS code | 9405500090 |
The same housing and the same weight as the 800 W, with half as much luminous flux again. For port terminals, large sports facilities, and industrial areas from high masts.
Version
Order code DARK06-50K · also available in 40K, 30K, 22K, and BIC
The strongest full cut-off we offer.
| Luminous flux | 307,800 lm |
| Power consumption | 1,800 W |
| Efficiency | 171 lm/W |
| Cut-off | 63°, 66°, 69°, 72°, 75° cut-off |
| Measured beam angle | 132° beam, 138° field, shielding position |
| Color temperatures | 1700K to 5700K, standard 4000K |
| Color-changeable | 4000K, 2200K and 1700K, switchable during operation |
| CRI (Ra) | > 70, or optionally 80 or 90 |
| Color consistency | 3-step MacAdam |
| Housing | cast aluminum, < 0.08 % copper |
| Surface treatment | conversion layer + 2-layer titanium e-coating |
| Bracket | High tensile strength 316L, −20° to +20° |
| Front | impact-resistant glass; luminaire rated at IK07 |
| Color | Titanium Black, Titanium Grey or Neutral White |
| Dimensions | 905 × 550 × 160 mm |
| Weight | 35.0 kg |
| Accessories | no |
| Voltage range | 180 to 528 VAC |
| Item variants | also in 40K, 30K, 22K and BIC |
| Current draw | approx. 4.8 A at 380 V, 8.2 A at 220 V |
| Driver | external, 3× TLD600 in DRB-2 or on a tray |
| Driver (type) | TLD600 (600 W), 3 per fixture |
| Driver lifespan | ≥ 100,000 hours at Tc 75 °C; ≥ 130,000 hours at Tc 50 °C |
| MTBF driver | ≥ 320,000 hours at Tc 75 °C (MIL-HDBK-217F) |
| Inrush current | 5.4 A peak, T50 8 ms at 220 V, per driver |
| Luminaires per MCB | B16: 1 · C16: 1 · C25: 1 · D16: 1 |
| Overvoltage | 6 kV line-to-line, 10 kV line-to-ground (IEC 61000-4-5) |
| Dimming | 0–10 V, PWM, and DALI-2 or via NFC |
| Power factor / THD | > 0.9 at 60–100 % load; THD < 15 % |
| IP and IK | IP66 and IP67 / IK07 |
| Operating temperature | −45 to +50 °C |
| LED lifespan | TM-21 L90B05 > 103,500 hours |
| Corrosion class | C5 Industrial and Maritime (ISO 9223) |
| Warranty | 5 years, with maintenance contract up to 10 years |
| Certification | CE, IEC 60598, EN 55015, EN 61547, EMC |
| HS code | 9405500090 |
One Three replaces multiple traditional floodlights, without a single lumen of stray light. For the largest sites and high mast applications. When choosing, pay attention to the load-bearing capacity of the structure: 35 kg per luminaire, plus wind load.
All the values above are also listed on the datasheet, complete with dimensions and the drill pattern.
The DarkLicht operates on 180 to 528 volts AC and is therefore intended for phase-to-phase and high-voltage connections. A version for 250 to 740 volts DC is available as an option, and a 24-volt DC variant of the DL1-600 is also available.
optional 250 to 740 VDC
at 50 or 60 Hz
PWM in DALI-2, or configurable via NFC
320 to 400 W internal, from 600 W external
The 320- and 400-watt models have an internal driver; starting at 600 watts, the driver is external, and the 1,200- and 1,800-watt models feature two and three TLD600 drivers, respectively, housed in a DRB-2. Dimming is supported via 0–10 V, PWM, or DALI-2, and settings can be configured via NFC; this allows you to set up a night mode or a schedule, which is the standard approach in commercial settings to further reduce energy consumption and light pollution outside of business hours.
At 220 V, two to four luminaires per driver fit on a C16 and four to eight on a C25, increasing with power: the 320 W achieves four on a C16, the 1,800 W only one. For a row of poles on a site, the voltage drop is usually the limiting factor, not the circuit breaker. Provide the number of poles, the power per pole, and the cable route, and we will calculate it and provide the load table with the lighting plan.
With a standard floodlight, you choose a lens and that fixes the beam. Here, you set the cut-off: the angle above which no more light comes out of the luminaire. That choice follows from the mounting height, the shape of the site, and how sensitive the surroundings are, and it can be changed on-site, even after the pole is installed.
On top of that, the square reflector modules can be rotated 90 degrees in both directions. This allows you to tilt the light distribution per position to match the shape of the terrain without having to choose a different luminaire.
| CUT-OFF | WHAT FOR |
|---|---|
| 75° | Maximum forward shielding, for low mounting heights. |
| 72° | The standard mode: the best balance between forward light and uniformity. |
| 69° | For the highest possible uniformity across the plane. |
| 66° | For lighting from extreme heights, above 50 meters. |
| 63° | For the strictest DarkSky zones, in combination with the lowest color temperatures, 1700 or 1800 K. |
The angle corresponding to your location is determined by the lighting calculation. We provide this calculation free of charge, including verification against the NSVV guideline on light pollution or your environmental permit; see lighting advice and lighting calculation. For outdoor workstations, we use EN 12464-2; for sports facilities, we use EN 12193.
With large installations, the difference lies not in the luminaire but in the power supply, the mounting, and the configuration. That is why we supply the DarkLicht as a system.
From the DL1-600 onwards, the driver is external, housed in an industrial driver box made of the same aluminum with titanium e-coating as the luminaires: IP67, optionally IP68, IK08, driver lifespan exceeding 130,000 hours, and a power factor above 0.95. The DRB-1 up to 200 W, the DRB-2 up to 2,000 W; one DRB-2 powers up to four luminaires.
The fact that the driver is located outside the luminaire has two practical consequences: the luminaire remains lighter on the pole, and the driver can be replaced without dismantling the luminaire. At a height of fifty meters, that saves a crane.
From fixed poles to portable setups, tailored to mounting height and cut-off. See light poles, high masts, and portable light poles.
Every DarkLicht installation is supported by a lighting calculation: number of luminaires, positions, cut-off angle, expected illuminance in lux, and compliance with the NSVV guideline or the permit. This service is provided free of charge, even if you use the plan elsewhere.
Sites where a permit, a guideline, or the neighborhood determines how much light is allowed to cross the boundary.
Using the DL-CCB-400+DIS crane frame, the DarkLicht illuminates the entire construction site from the boom, in compliance with DarkSky standards, as seen at the HSB construction site in Hilversum. No complaints from the neighborhood, yet a full view of the work.
At DFDS in Vlaardingen, the switch resulted in a 53 percent saving: the site lit up, the surroundings dark. BUSS Terminal Eemshaven and P&O Ferries chose the same approach.
While the NSVV guideline on light pollution and the environmental permit set the framework, the lighting determines whether work may continue at night. Fully shielded lighting, dimmable during nighttime hours.
For sports facilities that want to limit nuisance to local residents and nature, such as RKAV Volendam. Uniform match lighting on the pitch, no spill light into the neighborhood, and optionally 2200 K amber along a nature reserve.
The same reflector technology in eight sizes, from 4,800 to 307,800 lumens. One, Two, and Three are the fixed area floodlights for site and mast; the M is the version for cranes and mobile masts; the D and the WP are the simple outdoor luminaires; the S and the Mini are the work lights for machinery. Only the WP and the 320 W version are at 160 lm/W, the rest at 171.
| Luminaire | Luminous flux | Power | Role in the range | Weight |
|---|---|---|---|---|
| DarkLicht Three | 307,800 lm | 1,800 W | largest sites, high mast | 35.0 kg |
| DarkLicht Two | 136,800 to 205,200 lm | 800 to 1,200 W | terminals in industrial areas | 24.8 kg |
| DarkLicht One | 51,200 to 102,600 lm | 320 to 600 W | medium-sized grounds and sports fields | 14.0 to 15.0 kg |
| DarkLicht M | 25,700 to 51,300 lm | 150 to 300 W | cranes and mobile lighting towers | 3.6 to 5.5 kg |
| DarkLicht D | 10,300 to 34,200 lm | 60 to 200 W | parking and industrial areas | 6.9 to 8.5 kg |
| DarkLicht WP wallpack | 9,600 to 16,000 lm | 60 to 100 W | facades and entrances | 4.0 kg |
| DarkLicht S | 10,260 to 12,825 lm | 60 to 75 W | work light on machinery | 3.3 kg |
| DarkLicht Mini | 4,800 lm | 30 W | compact work lamp | 2.2 lbs |
The three sizes share the same height and depth: 550 by 160 mm. Only the width and weight increase with the number of reflector modules. The bracket is made of high-grade 316L stainless steel; the complete bolt pattern is listed in the datasheet.
| Model | DIMENSIONS | WEIGHT |
|---|---|---|
| One | 365 × 550 × 160 mm | 14.0 to 15.0 kg |
| Two | 635 × 550 × 160 mm | 24.8 kg |
| Three | 905 × 550 × 160 mm | 35.0 kg |
Dimensions in mm, width × height × depth. With the Three, pay attention to the load-bearing capacity of the structure: 35 kg per luminaire, plus wind load. DXF and STEP are available upon request.
DarkLicht One
DarkLicht Two
DarkLicht Three
Views with dimensions, follows the chosen execution. Do not cut into dimensions.
Every claim carries its condition in the same sentence. You can read more about the test methods at Product Quality and Warranty.
Above the adjustable cutoff, light output is zero, both forward and backward. At low color temperatures - 2200 K and below - the fixture thus meets the most stringent DarkSky specifications, including DS-1.
L90B05: At that point, at least 95 percent of the fixtures will still be delivering at least 90 percent of their original luminous flux. With continuous use 24 hours a day, that amounts to well over 11 years.
At DFDS in Vlaardingen, energy consumption fell by 53 percent thanks to a better-lit terminal; at P&O Ferries in Europoort, it fell by about 66 percent, with 30 new mast structures installed in two weeks.
The complete specification per version, including dimensions, drill pattern, and order code. Direct download, no form required.
STEP or DXF files for your own drawings, including the drilling pattern for the 316L bracket.
Per cutoff and color temperature, for your own calculation in DIALux or Relux.
Can't find your question? Call us, and we will walk through your site in five minutes. An engineer will respond within 1 business day.
Light control. A conventional floodlight uses lenses or an open optical system, which means that some of the light is always lost as glare and scattered light. The DarkLicht uses patented parabolic reflectors: above the adjustable cutoff, light output is zero,both forward and backward. All the light is directed onto the surface to be illuminated, which is why fewer luminaires are often needed to achieve the same level of illumination.
Yes. Because no light escapes above the cutoff, the upward light emission is zero, which means that the DarkLicht at low color temperatures (2200 K, 1800 K, or 1700 K) meets the strictest DarkSky specifications, including DS-1. With proper lighting design, the limits set by the NSVV light pollution guideline are also met in virtually all classes, even at high power levels. We substantiate this for each project with a lighting calculation.
That follows from the mounting height, the dimensions of the site and the sensitivity of the surroundings. As a rule of thumb: 75 degrees for low mounting, 72 degrees as standard, 69 degrees for maximum uniformity, 66 degrees from extreme heights above 50 meters, and 63 degrees in the strictest DarkSky zones, combined with 1700 or 1800 K. We substantiate the final choice with a lighting calculation, including the number of luminaires, the positions and the expected illuminance in lux.
CE and IEC 60598, along with the corresponding EMC standards. In addition, the luminaire is designed to comply with the NSVV light pollution guideline and, at low color temperatures, with the most stringent DarkSky specifications, including DS-1. For workplace lighting, the DarkLicht supports compliance with EN 12464-2, and for sports facilities, with EN 12193. For specific project requirements, we assess the certification status on a per-application basis.
Not from a classification society: there is no class approval from DNV, Lloyd’s, or Bureau Veritas. However, the fixture has been tested and approved by TÜV Rheinland in accordance with IEC 60598-1, IEC 60598-2-3, and IEC 60598-2-5; we will provide that test report upon request, along with the other certifications and the material specification. If your client or the specifications explicitly require class approval, please mention this in your request: we will assess on a project-by-project basis whether that process is feasible.
The drivers are equipped with surge protection; the exact value depends on the chosen driver configuration and the DRB box. When making your request, please indicate if a specific requirement applies, for example from a terminal standard or an insurer, and we will confirm the value with the quotation.
That depends on the power, voltage, and cable route. For a line of poles on a site, the voltage drop is usually the limiting factor, not the circuit breaker. Provide the number of poles, the power per pole, and the cable route, and we will calculate it and provide the load table with the plan.
The type designations are DL1, DL2, and DL3, followed by the wattage; the DC version of the One is called DL-O1-600DC and the crane frame DL-CCB-400+DIS. The cut-off position and light color are specified separately when ordering, as these follow from the lighting calculation rather than the product selection. The complete order codes can be found in the article classification. The HS code for the luminaires is 9405500090.
The M is the glare-free version for cranes, machinery, and mobile lighting towers: 150 to 300 W, 25,700 to 51,300 lumens, IP69K, and 3.6 to 5.5 kg. The large DarkLicht is the fixed floodlight for area and mast lighting: 320 to 1,800 W, up to 307,800 lumens per luminaire, with external drivers in DRB boxes from 1,200 W upwards.
The D is a simple outdoor floodlight ranging from 60 to 200 W with an internal driver, delivering 10,300 to 34,200 lumens, designed for parking lots, construction sites, and industrial grounds on poles ranging from four to twelve meters. The large DarkLicht picks up where the D leaves off: larger areas, taller masts, and power ratings up to 1,800 W, supplied as a system with driver boxes and lighting calculations.
Yes, that is a core application. Even pitch lighting across the field without stray light towards homes or nature, as at RKAV Volendam. In doing so, we calculate according to EN 12193, the standard for sports lighting, which sets requirements for illuminance and uniformity per level. For match visibility, 4000 to 5000 K is often chosen; if the field borders a nature reserve, 2200 K or lower is possible.
Yes. The aluminum housing contains less than 0.08 percent copper to minimize galvanic corrosion and features a two-layer titanium e-coating; the bracket is made of high-grade 316L stainless steel. This makes the luminaire suitable for ports, coastal locations, and industrial sites. For extremely corrosive environments, 316L versions are available within the DarkLicht family; please inquire about the options for each model.
Copper in aluminum accelerates galvanic corrosion as soon as the aluminum comes into contact with stainless steel or seawater. By deliberately keeping the copper content below 0.08 percent, that corrosion chain is broken. In combination with the 316L bracket and the titanium e-coating, the luminaire maintains its structural integrity, even during prolonged exposure to salt.
Yes. The fixture is model IP66 and IP67, making it completely dust- and waterproof for permanent outdoor use, with impact-resistant glass on the front and IK07 impact resistance. Periodic cleaning with a soft cloth or a low-pressure water jet is sufficient; the reflector itself is protected behind the glass.
The luminaire itself has no wearing parts. The external drivers in the DRB boxes are separately accessible and can be replaced without disassembling the luminaire; on a high mast, that is the difference between a service call and a crane. The recommended inspection is limited to periodically cleaning the glass and checking the mounting and cable entries.
The specified 103,500 hours is an L90B05 value: at that point, at least 95 percent of the luminaires still deliver at least 90 percent of the original luminous flux. That is a stricter measure than the common L70 and L80 specifications in the market. With continuous use of 24 hours a day, 103,500 hours amounts to well over eleven years. In practice, the LED is rarely the limiting factor; environmental load, temperature, corrosion, and installation quality determine the actual service life.
Provide the surface area, mast height, and surroundings. We determine the size, One, Two, or Three, the cut-off position, the light color, the driver configuration, and the mounting solution, supported by a lighting calculation and a light pollution assessment.
You will receive a response from the person who is also preparing your lighting calculation.
We use your information solely to review your request and respond to it.