Home / Products / Full cut-off floodlights / DarkLicht One, Two, and Three

DarkLicht full cut-off flat panel radiator

All lumens on the site, zero above: up to 307,800 lumens from a single luminaire at 171 lm/W, with an adjustable cut-off from 63 to 75 degrees.

A standard floodlight uses lenses and therefore always loses some of its light to glare and scattered light. The DarkLicht uses a patented parabolic reflector that directs the light onto the surface to be illuminated and not beside it. This not only reduces complaints from nearby residents: since no light escapes, you don’t need to generate as much, so you need fewer poles and fewer watts to achieve the same light level.

A response from an engineer within 1 business day. Free lighting calculation with a light pollution assessment.

Product rendering of the DarkLicht DL3 EXT full-cut-off floodlight

Titanium Black, with a frame made of 316L stainless steel.

Luminous flux
307.800 lm

de Three, 1,800 W, 171 lm/W

Up
0 %

above the set cut-off

Cut-off
63–75°

adjustable on-site

Power
320–1,800 W

six versions, three sizes

Protection
IP67

IP66 and IP67, IK07 with glass front

Warranty
5 years

up to 10 years with maintenance contract

Decision Aid

When should you choose the DarkLicht?

This luminaire is at its best where a lot of light needs to be cast on the site and nothing is allowed to spill over, because a permit, a guideline, or the neighborhood demands it.

  • A site, terminal, or sports field must be illuminated from masts
  • The NSVV light nuisance guideline, a DarkSky requirement, or an environmental permit determines the framework
  • homes, a road, a railway line, or nature border the site
  • Net yield counts: 171 lm/W without stray light means fewer poles and fewer watts
  • The cut-off must be different for each position: 63 to 75 degrees, adjustable on-site
  • The ambient light color must match: from 1700K amber to 5700K cool white
  • The installation must also include: dimmable, dual-color switchable, up to 10-year warranty

When another luminaire fits better

If light pollution plays no role, you are paying for lighting control that you do not need. We prefer to tell you that in advance.

  • If light pollution isn't an issue, the DCbright floodlights are a more cost-effective option
  • Whether it's a parking lot or a simple outdoor area: choose the DarkLicht D, 60 to 200 W
  • If the light needs to reach hundreds of meters with a spot-type lens: then the Orca
  • If it is to be installed on a machine or vehicle, it must be low-voltage: in that case, use the DarkLicht M or S
  • Whether it's a facade or an entrance: use the DarkLicht WP wallpack
  • ATEX or Ex certification is required: the DarkLicht does not have it
  • The construction does not bear the weight: count on 14 to 35 kg per luminaire
Versions

Three sizes, six capacities

One, Two and Three share the same reflector technology, the same 171 lm/W and the same adjustable cut-off; only the 320 W version is at 160 lm/W. What else differs is the number of reflector modules, and with it the power, length and weight.

Product rendering of the DarkLicht DL1 INT full-cut-off floodlight

DarkLicht One, 320 W

51,200 lm · 160 lm/W

The entry-level version with internal driver, for medium-sized grounds, construction sites and sports fields. The only version at 160 lm/W.

DARK01-50K · internal BLD320 · 14.9 kg

Product rendering of the DarkLicht DL1 INT full-cut-off floodlight

DarkLicht One, 400 W

68,400 lm · 171 lm/W

Same housing with a higher wattage. Internal driver, so one cable to the luminaire and no separate driver box on the pole.

DARK02-50K · internal TLD400 · 15.0 kg

Product rendering of the DarkLicht DL1 EXT full-cut-off floodlight

DarkLicht One, 600 W

102,600 lm · external driver

External driver in a DRB box: lighter on the mast than the 400 W and to be replaced at the base of the mast. Including the driver box, approximately 23 kg for the mast calculation.

DARK03-50K · TLD600 · 14.0 kg

Product rendering of the DarkLicht DL2 EXT full-cut-off floodlight

DarkLicht Two, 800 W

136,800 lm · external TLD800

The size mounted on most terminals: enough luminous flux to stretch the mast spacing, and still manageable to lift during maintenance.

DARK04-50K · 24.8 kg

Product rendering of the DarkLicht DL2 EXT full-cut-off floodlight

DarkLicht Two, 1,200 W

205,200 lm · 2× TLD600 in DRB-2

Same housing and weight as the 800 W, with half as much luminous flux again. For port terminals and large sports facilities from high masts.

DARK05-50K · 24.8 kg

Product rendering of the DarkLicht DL3 EXT full-cut-off floodlight

DarkLicht Three, 1,800 W

307,800 lm · DRB-2

One Three replaces multiple conventional floodlights, without a single lumen of stray light. Pay attention to the load-bearing capacity: 35 kg plus wind load.

DL3-1800 · 35.0 kg

Evidence

The terrain illuminated, the surroundings dark

At DFDS in Vlaardingen, the switch to DarkLicht resulted in a 53 percent reduction in energy consumption, while the terminal was better lit than before. The aerial photo shows how the reflector works: the area is brightly lit, and the edges are sharp. At P&O Ferries in Europoort, energy consumption dropped by about 66 percent, with thirty new mast structures installed in just two weeks at a terminal that continued to operate as usual.

BUSS Terminal Eemshaven, RKAV Volendam, and the HSB construction site in Hilversum also use the DarkLicht system.

Aerial view of the illuminated DFDS terminal in Vlaardingen with DarkLicht at night
DFDS Vlaardingen
53 %

lower energy consumption

P&O Ferries
66 %

lower consumption, 30 mast structures

Specifications

Full specification

Choose a trim level and the specification list, image, and dimensional drawing will change accordingly. One row of six, no nested tabs.

Version

DarkLicht One, 320 W

Order code DARK01-50K · also available in 40K, 30K, 22K, BIC, and PDL

Internal driver, for medium-sized terrains.

Product rendering of the DarkLicht DL1 INT full-cut-off floodlight
51,200 lm
Light and optics
Luminous flux51,200 lm
Power consumption320 W
Efficiency160 lm/W
Cut-off63°, 66°, 69°, 72°, 75° cut-off
Measured beam angle132° beam, 138° field, shielding position
Color temperatures1700K to 5700K, standard 4000K
Color-changeable4000K, 2200K and 1700K, switchable during operation
CRI (Ra)> 70, or optionally 80 or 90
Color consistency3-step MacAdam
Construction
Housingcast aluminum, < 0.08 % copper
Surface treatmentconversion layer + 2-layer titanium e-coating
BracketHigh tensile strength 316L, −20° to +20°
Frontimpact-resistant glass; luminaire rated at IK07
ColorTitanium Black, Titanium Grey or Neutral White
Dimensions365 × 550 × 160 mm
Weight14.9 kg
Lead timeStandard within a week, custom by arrangement
Accessoriestower crane frame
Electric
Voltage range180 to 528 VAC
Item variantsalso in 40K, 30K, 22K, BIC and PDL
Current drawapprox. 0.8 A at 380 V, 1.5 A at 220 V
Driverinternal BLD320
Driver (type)BLD320 (320 W)
Driver lifespan≥ 100,000 hours at Tc 75 °C; ≥ 130,000 hours at Tc 50 °C
MTBF driver≥ 280,000 hours at Tc 75 °C (MIL-HDBK-217F)
Inrush current31.2 A peak, T50 1.3 ms at 220 V
Luminaires per MCBB16: 2 · C16: 4 · C25: 7 · D16: 8
Overvoltage6 kV line-to-line, 10 kV line-to-ground (IEC 61000-4-5)
Dimming0–10 V, PWM, and DALI-2 or via NFC
Power factor / THD> 0.95 at 60–100 % load; THD < 15 %
Protection and durability
IP and IKIP66 and IP67 / IK07
Operating temperature−45 to +50 °C
LED lifespanTM-21 L90B05 > 103,500 hours
Corrosion classC5 Industrial and Maritime (ISO 9223)
Warranty5 years, with maintenance contract up to 10 years
CertificationCE, IEC 60598, EN 55015, EN 61547, EMC
HS code9405500090

The entry-level model in the large DarkLicht series, with an internal driver. Designed for medium-sized outdoor areas, construction sites, and sports fields. This is the only model with a luminous efficacy of 160 lm/W; all other models achieve 171 lm/W.

Version

DarkLicht One, 400 W

Order code DARK02-50K · also available in 40K, 30K, 22K, and BIC

Internal driver, for medium-sized terrains.

Product rendering of the DarkLicht DL1 INT full-cut-off floodlight
68,400 lm
Light and optics
Luminous flux68,400 lm
Power consumption400 W
Efficiency171 lm/W
Cut-off63°, 66°, 69°, 72°, 75° cut-off
Measured beam angle132° beam, 138° field, shielding position
Color temperatures1700K to 5700K, standard 4000K
Color-changeable4000K, 2200K and 1700K, switchable during operation
CRI (Ra)> 70, or optionally 80 or 90
Color consistency3-step MacAdam
Construction
Housingcast aluminum, < 0.08 % copper
Surface treatmentconversion layer + 2-layer titanium e-coating
BracketHigh tensile strength 316L, −20° to +20°
Frontimpact-resistant glass; luminaire rated at IK07
ColorTitanium Black, Titanium Grey or Neutral White
Dimensions365 × 550 × 160 mm
Weight15.0 kg
Accessoriestower crane frame
Electric
Voltage range180 to 528 VAC
Item variantsalso in 40K, 30K, 22K and BIC
Current drawapprox. 1.1 A at 380 V, 1.8 A at 220 V
Driverinternal TLD400
Driver (type)TLD400 (400 W)
Driver lifespan≥ 100,000 hours at Tc 75 °C; ≥ 130,000 hours at Tc 50 °C
MTBF driver≥ 280,000 hours at Tc 75 °C (MIL-HDBK-217F)
Inrush current64 A peak, T50 400 µs at 220 V
Luminaires per MCBB16: 4 · C16: 5 · C25: 8 · D16: 6
Overvoltage6 kV line-to-line, 10 kV line-to-ground (IEC 61000-4-5)
Dimming0–10 V, PWM, and DALI-2 or via NFC
Power factor / THD> 0.9 at 60–100 % load; THD < 15 %
Protection and durability
IP and IKIP66 and IP67 / IK07
Operating temperature−45 to +50 °C
LED lifespanTM-21 L90B05 > 103,500 hours
Corrosion classC5 Industrial and Maritime (ISO 9223)
Warranty5 years, with maintenance contract up to 10 years
CertificationCE, IEC 60598, EN 55015, EN 61547, EMC
HS code9405500090

Same housing as the 320 W with a higher power output. Internal driver, so one cable to the luminaire and no separate driver box on the pole.

Version

DarkLicht One, 600 W

Order code DARK03-50K · also available in 40K, 30K, 22K, and BIC

External driver, also available as 24 volt DC.

Product rendering of the DarkLicht DL1 EXT full-cut-off floodlight
102,600 lm
Light and optics
Luminous flux102,600 lm
Power consumption600 W
Efficiency171 lm/W
Cut-off63°, 66°, 69°, 72°, 75° cut-off
Measured beam angle132° beam, 138° field, shielding position
Color temperatures1700K to 5700K, standard 4000K
Color-changeable4000K, 2200K and 1700K, switchable during operation
CRI (Ra)> 70, or optionally 80 or 90
Color consistency3-step MacAdam
Construction
Housingcast aluminum, < 0.08 % copper
Surface treatmentconversion layer + 2-layer titanium e-coating
BracketHigh tensile strength 316L, −20° to +20°
Frontimpact-resistant glass; luminaire rated at IK07
ColorTitanium Black, Titanium Grey or Neutral White
Dimensions365 × 550 × 160 mm
Weight14.0 kg
Accessoriestower crane frame
Electric
Voltage range180 to 528 VAC
Item variantsalso in 40K, 30K, 22K and BIC
Current drawapprox. 1.6 A at 380 V, 2.7 A at 220 V
Driverexternal TLD600, in DRB driver box
Driver (type)TLD600 (600 W)
Driver lifespan≥ 100,000 hours at Tc 75 °C; ≥ 130,000 hours at Tc 50 °C
MTBF driver≥ 320,000 hours at Tc 75 °C (MIL-HDBK-217F)
Inrush current5.4 A peak, T50 8 ms at 220 V
Luminaires per MCBB16: 3 · C16: 3 · C25: 5 · D16: 4
Overvoltage6 kV line-to-line, 10 kV line-to-ground (IEC 61000-4-5)
Dimming0–10 V, PWM, and DALI-2 or via NFC
Power factor / THD> 0.9 at 60–100 % load; THD < 15 %
Protection and durability
IP and IKIP66 and IP67 / IK07
Operating temperature−45 to +50 °C
LED lifespanTM-21 L90B05 > 103,500 hours
Corrosion classC5 Industrial and Maritime (ISO 9223)
Warranty5 years, with maintenance contract up to 10 years
CertificationCE, IEC 60598, EN 55015, EN 61547, EMC
HS code9405500090

From this wattage onwards, the driver is housed externally in a DRB box. As a result, the luminaire is lighter than the 400W version, despite the higher wattage, and the driver can be replaced at the base of the mast. Also available as a 24-volt direct current version.

Version

DarkLicht Two, 800 W

Order code DARK04-50K · also available in 40K, 30K, 22K, and BIC

The workhorse for large properties.

Product rendering of the DarkLicht DL2 EXT full-cut-off floodlight
136,800 lm
Light and optics
Luminous flux136,800 lm
Power consumption800 W
Efficiency171 lm/W
Cut-off63°, 66°, 69°, 72°, 75° cut-off
Measured beam angle132° beam, 138° field, shielding position
Color temperatures1700K to 5700K, standard 4000K
Color-changeable4000K, 2200K and 1700K, switchable during operation
CRI (Ra)> 70, or optionally 80 or 90
Color consistency3-step MacAdam
Construction
Housingcast aluminum, < 0.08 % copper
Surface treatmentconversion layer + 2-layer titanium e-coating
BracketHigh tensile strength 316L, −20° to +20°
Frontimpact-resistant glass; luminaire rated at IK07
ColorTitanium Black, Titanium Grey or Neutral White
Dimensions635 × 550 × 160 mm
Weight24.8 kg
Accessoriesno
Electric
Voltage range180 to 528 VAC
Item variantsalso in 40K, 30K, 22K and BIC
Current drawapprox. 2.2 A at 380 V, 3.7 A at 220 V
Driverexternal TLD800
Driver (type)TLD800 (800 W)
Driver lifespan≥ 100,000 hours at Tc 75 °C; ≥ 130,000 hours at Tc 50 °C
MTBF driver≥ 320,000 hours at Tc 75 °C (MIL-HDBK-217F)
Inrush current5.4 A peak, T50 8 ms at 220 V
Luminaires per MCBB16: 2 · C16: 2 · C25: 4 · D16: 3
Overvoltage6 kV line-to-line, 10 kV line-to-ground (IEC 61000-4-5)
Dimming0–10 V, PWM, and DALI-2 or via NFC
Power factor / THD> 0.9 at 60–100 % load; THD < 15 %
Protection and durability
IP and IKIP66 and IP67 / IK07
Operating temperature−45 to +50 °C
LED lifespanTM-21 L90B05 > 103,500 hours
Corrosion classC5 Industrial and Maritime (ISO 9223)
Warranty5 years, with maintenance contract up to 10 years
CertificationCE, IEC 60598, EN 55015, EN 61547, EMC
HS code9405500090

The Two is the size installed on most terminals: enough luminous flux to stretch the pole spacing, and still manageable to lift during maintenance. Like the 400 W One, this version has an internal driver; starting from 1,200 W, the driver is external.

Version

DarkLicht Two, 1,200 W

Order code DARK05-50K · also available in 40K, 30K, 22K, and BIC

External driver in DRB-2.

Product rendering of the DarkLicht DL2 EXT full-cut-off floodlight
205,200 lm
Light and optics
Luminous flux205,200 lm
Power consumption1,200 W
Efficiency171 lm/W
Cut-off63°, 66°, 69°, 72°, 75° cut-off
Measured beam angle132° beam, 138° field, shielding position
Color temperatures1700K to 5700K, standard 4000K
Color-changeable4000K, 2200K and 1700K, switchable during operation
CRI (Ra)> 70, or optionally 80 or 90
Color consistency3-step MacAdam
Construction
Housingcast aluminum, < 0.08 % copper
Surface treatmentconversion layer + 2-layer titanium e-coating
BracketHigh tensile strength 316L, −20° to +20°
Frontimpact-resistant glass; luminaire rated at IK07
ColorTitanium Black, Titanium Grey or Neutral White
Dimensions635 × 550 × 160 mm
Weight24.8 kg
Accessoriesno
Electric
Voltage range180 to 528 VAC
Item variantsalso in 40K, 30K, 22K and BIC
Current drawapprox. 3.2 A at 380 V, 5.5 A at 220 V
Driverexternal, 2× TLD600 in DRB-2 or on a tray
Driver (type)TLD600 (600 W), 2 per fixture
Driver lifespan≥ 100,000 hours at Tc 75 °C; ≥ 130,000 hours at Tc 50 °C
MTBF driver≥ 320,000 hours at Tc 75 °C (MIL-HDBK-217F)
Inrush current5.4 A peak, T50 8 ms at 220 V, per driver
Luminaires per MCBB16: 1 · C16: 1 · C25: 2 · D16: 2
Overvoltage6 kV line-to-line, 10 kV line-to-ground (IEC 61000-4-5)
Dimming0–10 V, PWM, and DALI-2 or via NFC
Power factor / THD> 0.9 at 60–100 % load; THD < 15 %
Protection and durability
IP and IKIP66 and IP67 / IK07
Operating temperature−45 to +50 °C
LED lifespanTM-21 L90B05 > 103,500 hours
Corrosion classC5 Industrial and Maritime (ISO 9223)
Warranty5 years, with maintenance contract up to 10 years
CertificationCE, IEC 60598, EN 55015, EN 61547, EMC
HS code9405500090

The same housing and the same weight as the 800 W, with half as much luminous flux again. For port terminals, large sports facilities, and industrial areas from high masts.

Version

DarkLicht Three, 1,800 W

Order code DARK06-50K · also available in 40K, 30K, 22K, and BIC

The strongest full cut-off we offer.

Product rendering of the DarkLicht DL3 EXT full-cut-off floodlight
307,800 lm
Light and optics
Luminous flux307,800 lm
Power consumption1,800 W
Efficiency171 lm/W
Cut-off63°, 66°, 69°, 72°, 75° cut-off
Measured beam angle132° beam, 138° field, shielding position
Color temperatures1700K to 5700K, standard 4000K
Color-changeable4000K, 2200K and 1700K, switchable during operation
CRI (Ra)> 70, or optionally 80 or 90
Color consistency3-step MacAdam
Construction
Housingcast aluminum, < 0.08 % copper
Surface treatmentconversion layer + 2-layer titanium e-coating
BracketHigh tensile strength 316L, −20° to +20°
Frontimpact-resistant glass; luminaire rated at IK07
ColorTitanium Black, Titanium Grey or Neutral White
Dimensions905 × 550 × 160 mm
Weight35.0 kg
Accessoriesno
Electric
Voltage range180 to 528 VAC
Item variantsalso in 40K, 30K, 22K and BIC
Current drawapprox. 4.8 A at 380 V, 8.2 A at 220 V
Driverexternal, 3× TLD600 in DRB-2 or on a tray
Driver (type)TLD600 (600 W), 3 per fixture
Driver lifespan≥ 100,000 hours at Tc 75 °C; ≥ 130,000 hours at Tc 50 °C
MTBF driver≥ 320,000 hours at Tc 75 °C (MIL-HDBK-217F)
Inrush current5.4 A peak, T50 8 ms at 220 V, per driver
Luminaires per MCBB16: 1 · C16: 1 · C25: 1 · D16: 1
Overvoltage6 kV line-to-line, 10 kV line-to-ground (IEC 61000-4-5)
Dimming0–10 V, PWM, and DALI-2 or via NFC
Power factor / THD> 0.9 at 60–100 % load; THD < 15 %
Protection and durability
IP and IKIP66 and IP67 / IK07
Operating temperature−45 to +50 °C
LED lifespanTM-21 L90B05 > 103,500 hours
Corrosion classC5 Industrial and Maritime (ISO 9223)
Warranty5 years, with maintenance contract up to 10 years
CertificationCE, IEC 60598, EN 55015, EN 61547, EMC
HS code9405500090

One Three replaces multiple traditional floodlights, without a single lumen of stray light. For the largest sites and high mast applications. When choosing, pay attention to the load-bearing capacity of the structure: 35 kg per luminaire, plus wind load.

All the values above are also listed on the datasheet, complete with dimensions and the drill pattern.

For the installer

Connect and integrate into the installation

The DarkLicht operates on 180 to 528 volts AC and is therefore intended for phase-to-phase and high-voltage connections. A version for 250 to 740 volts DC is available as an option, and a 24-volt DC variant of the DL1-600 is also available.

Voltage range
180–528 VAC

optional 250 to 740 VDC

Power factor
0.99

at 50 or 60 Hz

Dimming
0–10 V

PWM in DALI-2, or configurable via NFC

Driver position
intern at DRB

320 to 400 W internal, from 600 W external

Group tax and night rate

The 320- and 400-watt models have an internal driver; starting at 600 watts, the driver is external, and the 1,200- and 1,800-watt models feature two and three TLD600 drivers, respectively, housed in a DRB-2. Dimming is supported via 0–10 V, PWM, or DALI-2, and settings can be configured via NFC; this allows you to set up a night mode or a schedule, which is the standard approach in commercial settings to further reduce energy consumption and light pollution outside of business hours.

At 220 V, two to four luminaires per driver fit on a C16 and four to eight on a C25, increasing with power: the 320 W achieves four on a C16, the 1,800 W only one. For a row of poles on a site, the voltage drop is usually the limiting factor, not the circuit breaker. Provide the number of poles, the power per pole, and the cable route, and we will calculate it and provide the load table with the lighting plan.

Other electrical
  • Mains frequency 50 or 60 Hz
  • Surge Protection: 6 kV Line-to-Line and 10 kV Line-to-Ground (IEC 61000-4-5)
  • DRB-1 up to 200 W, DRB-2 up to 2,000 W; a single DRB-2 powers up to four fixtures
  • Driver lifespan ≥ 100,000 hours at Tc 75 °C and ≥ 130,000 hours at Tc 50 °C; MTBF 280,000 to 320,000 hours (MIL-HDBK-217F)
  • Power factor > 0.9 and THD < 15 % at a load of 60 to 100 %; 320 W > 0,95
  • HS code of the luminaires 9405500090
Light image

The cut-off determines where the light ends

With a standard floodlight, you choose a lens and that fixes the beam. Here, you set the cut-off: the angle above which no more light comes out of the luminaire. That choice follows from the mounting height, the shape of the site, and how sensitive the surroundings are, and it can be changed on-site, even after the pole is installed.

On top of that, the square reflector modules can be rotated 90 degrees in both directions. This allows you to tilt the light distribution per position to match the shape of the terrain without having to choose a different luminaire.

CUT-OFFWHAT FOR
75°Maximum forward shielding, for low mounting heights.
72°The standard mode: the best balance between forward light and uniformity.
69°For the highest possible uniformity across the plane.
66°For lighting from extreme heights, above 50 meters.
63°For the strictest DarkSky zones, in combination with the lowest color temperatures, 1700 or 1800 K.
Product rendering of the DarkLicht DL2 EXT full-cut-off floodlight

The angle corresponding to your location is determined by the lighting calculation. We provide this calculation free of charge, including verification against the NSVV guideline on light pollution or your environmental permit; see lighting advice and lighting calculation. For outdoor workstations, we use EN 12464-2; for sports facilities, we use EN 12193.

More than a luminaire

The system around it determines the end result

With large installations, the difference lies not in the luminaire but in the power supply, the mounting, and the configuration. That is why we supply the DarkLicht as a system.

DRB-driverbox

From the DL1-600 onwards, the driver is external, housed in an industrial driver box made of the same aluminum with titanium e-coating as the luminaires: IP67, optionally IP68, IK08, driver lifespan exceeding 130,000 hours, and a power factor above 0.95. The DRB-1 up to 200 W, the DRB-2 up to 2,000 W; one DRB-2 powers up to four luminaires.

The fact that the driver is located outside the luminaire has two practical consequences: the luminaire remains lighter on the pole, and the driver can be replaced without dismantling the luminaire. At a height of fifty meters, that saves a crane.

Mast and assembly solutions

From fixed poles to portable setups, tailored to mounting height and cut-off. See light poles, high masts, and portable light poles.

Light calculation and light pollution assessment

Every DarkLicht installation is supported by a lighting calculation: number of luminaires, positions, cut-off angle, expected illuminance in lux, and compliance with the NSVV guideline or the permit. This service is provided free of charge, even if you use the plan elsewhere.

Applications

Where the light must remain within the property boundary

Sites where a permit, a guideline, or the neighborhood determines how much light is allowed to cross the boundary.

Tower crane at night with sustainable LED lighting

Tower cranes and construction sites

Using the DL-CCB-400+DIS crane frame, the DarkLicht illuminates the entire construction site from the boom, in compliance with DarkSky standards, as seen at the HSB construction site in Hilversum. No complaints from the neighborhood, yet a full view of the work.

Aerial view of the illuminated DFDS terminal in Vlaardingen with DarkLicht at night

Ports and terminals

At DFDS in Vlaardingen, the switch resulted in a 53 percent saving: the site lit up, the surroundings dark. BUSS Terminal Eemshaven and P&O Ferries chose the same approach.

Light pole with LED floodlights at the Verbrugge terminal

Construction and infrastructure

While the NSVV guideline on light pollution and the environmental permit set the framework, the lighting determines whether work may continue at night. Fully shielded lighting, dimmable during nighttime hours.

FC Volendam stadium field at night with LED lighting

Sports Fields and Stadiums

For sports facilities that want to limit nuisance to local residents and nature, such as RKAV Volendam. Uniform match lighting on the pitch, no spill light into the neighborhood, and optionally 2200 K amber along a nature reserve.

Product family

The DarkLicht Line in Perspective

The same reflector technology in eight sizes, from 4,800 to 307,800 lumens. One, Two, and Three are the fixed area floodlights for site and mast; the M is the version for cranes and mobile masts; the D and the WP are the simple outdoor luminaires; the S and the Mini are the work lights for machinery. Only the WP and the 320 W version are at 160 lm/W, the rest at 171.

LuminaireLuminous fluxPowerRole in the rangeWeight
DarkLicht Three307,800 lm1,800 Wlargest sites, high mast35.0 kg
DarkLicht Two136,800 to 205,200 lm800 to 1,200 Wterminals in industrial areas24.8 kg
DarkLicht One51,200 to 102,600 lm320 to 600 Wmedium-sized grounds and sports fields14.0 to 15.0 kg
DarkLicht M25,700 to 51,300 lm150 to 300 Wcranes and mobile lighting towers3.6 to 5.5 kg
DarkLicht D10,300 to 34,200 lm60 to 200 Wparking and industrial areas6.9 to 8.5 kg
DarkLicht WP wallpack9,600 to 16,000 lm60 to 100 Wfacades and entrances4.0 kg
DarkLicht S10,260 to 12,825 lm60 to 75 Wwork light on machinery3.3 kg
DarkLicht Mini4,800 lm30 Wcompact work lamp2.2 lbs
Dimensioning

Dimensioning

The three sizes share the same height and depth: 550 by 160 mm. Only the width and weight increase with the number of reflector modules. The bracket is made of high-grade 316L stainless steel; the complete bolt pattern is listed in the datasheet.

ModelDIMENSIONSWEIGHT
One365 × 550 × 160 mm14.0 to 15.0 kg
Two635 × 550 × 160 mm24.8 kg
Three905 × 550 × 160 mm35.0 kg

Dimensions in mm, width × height × depth. With the Three, pay attention to the load-bearing capacity of the structure: 35 kg per luminaire, plus wind load. DXF and STEP are available upon request.

Technical drawing showing the dimensions of the DarkLicht DL-O1

DarkLicht One

Technical drawing showing the dimensions of the DarkLicht DL-O2

DarkLicht Two

Technical drawing showing the dimensions of the DarkLicht DL-O3

DarkLicht Three

Views with dimensions, follows the chosen execution. Do not cut into dimensions.

Evidence

Tested, not promised

Every claim carries its condition in the same sentence. You can read more about the test methods at Product Quality and Warranty.

Lighting control
0 % up

Above the adjustable cutoff, light output is zero, both forward and backward. At low color temperatures - 2200 K and below - the fixture thus meets the most stringent DarkSky specifications, including DS-1.

Lifespan · TM-21
103,500 hours

L90B05: At that point, at least 95 percent of the fixtures will still be delivering at least 90 percent of their original luminous flux. With continuous use 24 hours a day, that amounts to well over 11 years.

Practice
53 % savings

At DFDS in Vlaardingen, energy consumption fell by 53 percent thanks to a better-lit terminal; at P&O Ferries in Europoort, it fell by about 66 percent, with 30 new mast structures installed in two weeks.

Downloads

Downloads

Data Sheet

The complete specification per version, including dimensions, drill pattern, and order code. Direct download, no form required.

3D file

STEP or DXF files for your own drawings, including the drilling pattern for the 316L bracket.

IES files

Per cutoff and color temperature, for your own calculation in DIALux or Relux.

FAQ

Frequently Asked Questions About the DarkLicht

Can't find your question? Call us, and we will walk through your site in five minutes. An engineer will respond within 1 business day.

Light control. A conventional floodlight uses lenses or an open optical system, which means that some of the light is always lost as glare and scattered light. The DarkLicht uses patented parabolic reflectors: above the adjustable cutoff, light output is zero,both forward and backward. All the light is directed onto the surface to be illuminated, which is why fewer luminaires are often needed to achieve the same level of illumination.

Yes. Because no light escapes above the cutoff, the upward light emission is zero, which means that the DarkLicht at low color temperatures (2200 K, 1800 K, or 1700 K) meets the strictest DarkSky specifications, including DS-1. With proper lighting design, the limits set by the NSVV light pollution guideline are also met in virtually all classes, even at high power levels. We substantiate this for each project with a lighting calculation.

That follows from the mounting height, the dimensions of the site and the sensitivity of the surroundings. As a rule of thumb: 75 degrees for low mounting, 72 degrees as standard, 69 degrees for maximum uniformity, 66 degrees from extreme heights above 50 meters, and 63 degrees in the strictest DarkSky zones, combined with 1700 or 1800 K. We substantiate the final choice with a lighting calculation, including the number of luminaires, the positions and the expected illuminance in lux.

CE and IEC 60598, along with the corresponding EMC standards. In addition, the luminaire is designed to comply with the NSVV light pollution guideline and, at low color temperatures, with the most stringent DarkSky specifications, including DS-1. For workplace lighting, the DarkLicht supports compliance with EN 12464-2, and for sports facilities, with EN 12193. For specific project requirements, we assess the certification status on a per-application basis.

Not from a classification society: there is no class approval from DNV, Lloyd’s, or Bureau Veritas. However, the fixture has been tested and approved by TÜV Rheinland in accordance with IEC 60598-1, IEC 60598-2-3, and IEC 60598-2-5; we will provide that test report upon request, along with the other certifications and the material specification. If your client or the specifications explicitly require class approval, please mention this in your request: we will assess on a project-by-project basis whether that process is feasible.

The drivers are equipped with surge protection; the exact value depends on the chosen driver configuration and the DRB box. When making your request, please indicate if a specific requirement applies, for example from a terminal standard or an insurer, and we will confirm the value with the quotation.

That depends on the power, voltage, and cable route. For a line of poles on a site, the voltage drop is usually the limiting factor, not the circuit breaker. Provide the number of poles, the power per pole, and the cable route, and we will calculate it and provide the load table with the plan.

The type designations are DL1, DL2, and DL3, followed by the wattage; the DC version of the One is called DL-O1-600DC and the crane frame DL-CCB-400+DIS. The cut-off position and light color are specified separately when ordering, as these follow from the lighting calculation rather than the product selection. The complete order codes can be found in the article classification. The HS code for the luminaires is 9405500090.

The M is the glare-free version for cranes, machinery, and mobile lighting towers: 150 to 300 W, 25,700 to 51,300 lumens, IP69K, and 3.6 to 5.5 kg. The large DarkLicht is the fixed floodlight for area and mast lighting: 320 to 1,800 W, up to 307,800 lumens per luminaire, with external drivers in DRB boxes from 1,200 W upwards.

The D is a simple outdoor floodlight ranging from 60 to 200 W with an internal driver, delivering 10,300 to 34,200 lumens, designed for parking lots, construction sites, and industrial grounds on poles ranging from four to twelve meters. The large DarkLicht picks up where the D leaves off: larger areas, taller masts, and power ratings up to 1,800 W, supplied as a system with driver boxes and lighting calculations.

Yes, that is a core application. Even pitch lighting across the field without stray light towards homes or nature, as at RKAV Volendam. In doing so, we calculate according to EN 12193, the standard for sports lighting, which sets requirements for illuminance and uniformity per level. For match visibility, 4000 to 5000 K is often chosen; if the field borders a nature reserve, 2200 K or lower is possible.

Yes. The aluminum housing contains less than 0.08 percent copper to minimize galvanic corrosion and features a two-layer titanium e-coating; the bracket is made of high-grade 316L stainless steel. This makes the luminaire suitable for ports, coastal locations, and industrial sites. For extremely corrosive environments, 316L versions are available within the DarkLicht family; please inquire about the options for each model.

Copper in aluminum accelerates galvanic corrosion as soon as the aluminum comes into contact with stainless steel or seawater. By deliberately keeping the copper content below 0.08 percent, that corrosion chain is broken. In combination with the 316L bracket and the titanium e-coating, the luminaire maintains its structural integrity, even during prolonged exposure to salt.

Yes. The fixture is model IP66 and IP67, making it completely dust- and waterproof for permanent outdoor use, with impact-resistant glass on the front and IK07 impact resistance. Periodic cleaning with a soft cloth or a low-pressure water jet is sufficient; the reflector itself is protected behind the glass.

The luminaire itself has no wearing parts. The external drivers in the DRB boxes are separately accessible and can be replaced without disassembling the luminaire; on a high mast, that is the difference between a service call and a crane. The recommended inspection is limited to periodically cleaning the glass and checking the mounting and cable entries.

The specified 103,500 hours is an L90B05 value: at that point, at least 95 percent of the luminaires still deliver at least 90 percent of the original luminous flux. That is a stricter measure than the common L70 and L80 specifications in the market. With continuous use of 24 hours a day, 103,500 hours amounts to well over eleven years. In practice, the LED is rarely the limiting factor; environmental load, temperature, corrosion, and installation quality determine the actual service life.

Request

Have your property evaluated

Provide the surface area, mast height, and surroundings. We determine the size, One, Two, or Three, the cut-off position, the light color, the driver configuration, and the mounting solution, supported by a lighting calculation and a light pollution assessment.

Portrait photo of Lucas de Graaf
Lucas de Graaf

Technical Director, JEL Products

You will receive a response from the person who is also preparing your lighting calculation.

  • A reply within one working day, from an engineer
  • Free lighting design, including a nuisance assessment in accordance with NSVV or a permit
  • Test fixture available, in your own position
  • 5-year warranty, with maintenance contract up to 10 years
Rather direct contact
We respond within one working day. We deliver standard items within a week. Custom work, such as a different light colour, a different CRI or a bespoke version, by arrangement.

We use your information solely to review your request and respond to it.