Home / Products / Linear accelerators / DarkLicht One, Two, and Three

Full cut-off floodlight, 320 to 1,800 W

DarkLicht: all lights on the grounds, none above them

Up to 307,800 lumens from a single luminaire at 171 lm/W, with an adjustable cut-off from 63 to 75 degrees. Above that angle, the light output is zero, both forwards and backwards.

A standard floodlight uses lenses and therefore always loses some of its light to glare and scattered light. The DarkLicht uses a patented parabolic reflector that directs the light onto the surface to be illuminated and not beside it. This not only reduces complaints from nearby residents: since no light escapes, you don’t need to generate as much, so you need fewer poles and fewer watts to achieve the same light level.

Response within 1 business day by an engineer5-year warranty, upgradeable to 10Free lighting calculation

Product rendering of the DarkLicht DL3 EXT full-cut-off floodlight
307.800 lmFrom a single luminaire, the DL3171 lumens per wattNet, across the board0 % upAbove the set cut-off
The choice

When the DarkLicht Is the Right Choice, and When It Isn't

This fixture is at its best where a lot of light is needed on the site and none of it may spill over, because a permit, a guideline, or the neighborhood requires it. If that is not an issue, you are paying for light control that you do not need.

A logical choice when

A site, terminal, or sports field must be illuminated from masts
The NSVV light nuisance guideline, a DarkSky requirement, or an environmental permit determines the framework
homes, a road, a railway line, or nature border the site
Net yield counts: 171 lm/W without stray light means fewer poles and fewer watts
The cut-off must be different for each position: 63 to 75 degrees, adjustable on-site
The ambient light color must match: from 1700K amber to 5700K cool white
The installation must also include: dimmable, dual-color switchable, up to 10-year warranty

Usually not the right choice when

light pollution plays no role: then the DCbright floodlights more affordable
Whether it concerns a parking lot or a simple outdoor surface: then the DarkLicht D, 60 to 200 W
The light must reach hundreds of meters away with a spotlight optic: then the Orca
It on a machine or vehicle must, at low voltage: than the DarkLicht M or S
ATEX or Ex certification is required: the DarkLicht does not have it
The construction does not bear the weight: count on 14 to 35 kg per luminaire
Evidence

The terrain illuminated, the surroundings dark

At DFDS in Vlaardingen, the switch to DarkLicht resulted in a 53 percent reduction in energy consumption, while the terminal was better lit than before. The aerial photo shows how the reflector works: the area is brightly lit, and the edges are sharply defined. At P&O Ferries in Europoort, energy consumption dropped by approximately 66 percent, with thirty new mast structures installed in just two weeks at a terminal that continued to operate as usual.

BUSS Terminal Eemshaven, RKAV Volendam, and the HSB construction site in Hilversum also use the DarkLicht system.

Aerial view of the illuminated DFDS terminal in Vlaardingen with DarkLicht at night
53 %Lower consumption, DFDS Vlaardingen66 %Lower consumption, P&O Ferries
Versions and specifications

Three sizes, six capacities

One, Two and Three share the same reflector technology, the same 171 lm/W and the same adjustable cut-off; only the 320 W version is at 160 lm/W. What else differs is the number of reflector modules, and thus the power, length and weight. Choose a version below.

DarkLicht One, 320 W

internal driver, for medium-sized terrain

Product rendering of the DarkLicht DL1 INT full-cut-off floodlight
51.200 lmLuminous flux160 lumens per wattEfficiency
320 WPower absorbed15,0 kgLuminaire weight
Electric
Voltage range180 to 528 VAC
Performancesoptional 250 to 740 VDC
Power consumptionapprox. 0.8 A at 380 V, 1.5 A at 220 V
Power absorbed320 W
Driverintern
Dim0-10 V, optional DALI
Construction
Housingaluminum, < 0.08 % copper
Coatingconversion layer with 2-layer titanium e-coating
Bracehigh-grade 316L stainless steel
Frontthermally toughened glass
ColorTitanium Black
IP and IKIP67 / IK07
Light and optics
Cut-off63° to 75°, adjustable on-site
Reflector modules90° rotatable, both directions
Light Colors5700K to 1700K, standard 4000K
Two-coloredcool white with amber, on request
CRI (Ra)> 70, optionally 80 or 90
Color consistency3-step MacAdam ellipse
Sustainability and size
Company temperature-45 to +50 °C
LED lifespanTM-21 L90B05, 103,500 hours
Power factor and frequency0.99 at 50 or 60 Hz
Dimensions365 × 550 × 160 mm
CertificationCE, IEC 60598, EMC
Warranty5 years, expandable to 10

The entry-level model in the large DarkLicht series, with an internal driver. Designed for medium-sized outdoor areas, construction sites, and sports fields. This is the only model with a luminous efficacy of 160 lm/W; all other models achieve 171 lm/W.

DarkLicht One, 400 W

internal driver, for medium-sized terrain

Product rendering of the DarkLicht DL1 INT full-cut-off floodlight
68.400 lmLuminous flux171 lumens per wattEfficiency
400 WPower absorbed14,9 kgLuminaire weight
Electric
Voltage range180 to 528 VAC
Performancesoptional 250 to 740 VDC
Power consumptionapprox. 1.1 A at 380 V, 1.8 A at 220 V
Power absorbed400 W
Driverintern
Dim0-10 V, optional DALI
Construction
Housingaluminum, < 0.08 % copper
Coatingconversion layer with 2-layer titanium e-coating
Bracehigh-grade 316L stainless steel
Frontthermally toughened glass
ColorTitanium Black
IP and IKIP67 / IK07
Light and optics
Cut-off63° to 75°, adjustable on-site
Reflector modules90° rotatable, both directions
Light Colors5700K to 1700K, standard 4000K
Two-coloredcool white with amber, on request
CRI (Ra)> 70, optionally 80 or 90
Color consistency3-step MacAdam ellipse
Sustainability and size
Company temperature-45 to +50 °C
LED lifespanTM-21 L90B05, 103,500 hours
Power factor and frequency0.99 at 50 or 60 Hz
Dimensions365 × 550 × 160 mm
CertificationCE, IEC 60598, EMC
Warranty5 years, expandable to 10

Same housing as the 320 W with a higher power output. Internal driver, so one cable to the luminaire and no separate driver box on the pole.

DarkLicht One, 600 W

external driver, also as 24 volt DC

Product rendering of the DarkLicht DL1 EXT full-cut-off floodlight
102.600 lmLuminous flux171 lumens per wattEfficiency
600 WPower absorbed14,0 kgLuminaire weight
Electric
Voltage range180 to 528 VAC
Performancesalso as 24 VDC, DL-O1-600DC
Power consumptionapprox. 1.6 A at 380 V, 2.7 A at 220 V
Power absorbed600 W
Driverextern, in DRB-driverbox
Dim0-10 V, optional DALI
Construction
Housingaluminum, < 0.08 % copper
Coatingconversion layer with 2-layer titanium e-coating
Bracehigh-grade 316L stainless steel
Frontthermally toughened glass
ColorTitanium Black
IP and IKIP67 / IK07
Light and optics
Cut-off63° to 75°, adjustable on-site
Reflector modules90° rotatable, both directions
Light Colors5700K to 1700K, standard 4000K
Two-coloredcool white with amber, on request
CRI (Ra)> 70, optionally 80 or 90
Color consistency3-step MacAdam ellipse
Sustainability and size
Company temperature-45 to +50 °C
LED lifespanTM-21 L90B05, 103,500 hours
Power factor and frequency0.99 at 50 or 60 Hz
Dimensions365 × 550 × 160 mm
CertificationCE, IEC 60598, EMC
Warranty5 years, expandable to 10

From this wattage onwards, the driver is housed externally in a DRB box. As a result, the luminaire is lighter than the 400W version, despite the higher wattage, and the driver can be replaced at the base of the mast. Also available as a 24-volt direct current version.

DarkLicht Two, 800 W

the workhorse for large properties

Product rendering of the DarkLicht DL2 EXT full-cut-off floodlight
136.800 lmLuminous flux171 lumens per wattEfficiency
800 WPower absorbed24,8 kgLuminaire weight
Electric
Voltage range180 to 528 VAC
Performancesoptional 250 to 740 VDC
Power consumptionapprox. 2.2 A at 380 V, 3.7 A at 220 V
Power absorbed800 W
Driverintern
Dim0-10 V, optional DALI
Construction
Housingaluminum, < 0.08 % copper
Coatingconversion layer with 2-layer titanium e-coating
Bracehigh-grade 316L stainless steel
Frontthermally toughened glass
ColorTitanium Black
IP and IKIP67 / IK07
Light and optics
Cut-off63° to 75°, adjustable on-site
Reflector modules90° rotatable, both directions
Light Colors5700K to 1700K, standard 4000K
Two-coloredcool white with amber, on request
CRI (Ra)> 70, optionally 80 or 90
Color consistency3-step MacAdam ellipse
Sustainability and size
Company temperature-45 to +50 °C
LED lifespanTM-21 L90B05, 103,500 hours
Power factor and frequency0.99 at 50 or 60 Hz
Dimensions635 × 550 × 160 mm
CertificationCE, IEC 60598, EMC
Warranty5 years, expandable to 10

The Two is the size installed on most terminals: enough luminous flux to stretch the pole spacing, and still manageable to lift during maintenance. Like the 400 W One, this version has an internal driver; starting from 1,200 W, the driver is external.

DarkLicht Two, 1,200 W

external driver in DRB-2

Product rendering of the DarkLicht DL2 EXT full-cut-off floodlight
205.200 lmLuminous flux171 lumens per wattEfficiency
1.200 WPower absorbed24,8 kgLuminaire weight
Electric
Voltage range180 to 528 VAC
Performancesoptional 250 to 740 VDC
Power consumptionapprox. 3.2 A at 380 V, 5.5 A at 220 V
Power absorbed1,200 W
Driverexternal, in DRB-2 driverbox
Dim0-10 V, optional DALI
Construction
Housingaluminum, < 0.08 % copper
Coatingconversion layer with 2-layer titanium e-coating
Bracehigh-grade 316L stainless steel
Frontthermally toughened glass
ColorTitanium Black
IP and IKIP67 / IK07
Light and optics
Cut-off63° to 75°, adjustable on-site
Reflector modules90° rotatable, both directions
Light Colors5700K to 1700K, standard 4000K
Two-coloredcool white with amber, on request
CRI (Ra)> 70, optionally 80 or 90
Color consistency3-step MacAdam ellipse
Sustainability and size
Company temperature-45 to +50 °C
LED lifespanTM-21 L90B05, 103,500 hours
Power factor and frequency0.99 at 50 or 60 Hz
Dimensions635 × 550 × 160 mm
CertificationCE, IEC 60598, EMC
Warranty5 years, expandable to 10

The same housing and the same weight as the 800 W, with half as much luminous flux again. For port terminals, large sports facilities, and industrial areas from high masts.

DarkLicht Three, 1,800 W

the strongest full cut-off we supply

Product rendering of the DarkLicht DL3 EXT full-cut-off floodlight
307.800 lmLuminous flux171 lumens per wattEfficiency
1.800 WPower absorbed35,0 kgLuminaire weight
Electric
Voltage range180 to 528 VAC
Performancesoptional 250 to 740 VDC
Power consumptionapprox. 4.8 A at 380 V, 8.2 A at 220 V
Power absorbed1,800 W
Driverexternal, in DRB-2 driverbox
Dim0-10 V, optional DALI
Construction
Housingaluminum, < 0.08 % copper
Coatingconversion layer with 2-layer titanium e-coating
Bracehigh-grade 316L stainless steel
Frontthermally toughened glass
ColorTitanium Black
IP and IKIP67 / IK07
Light and optics
Cut-off63° to 75°, adjustable on-site
Reflector modules90° rotatable, both directions
Light Colors5700K to 1700K, standard 4000K
Two-coloredcool white with amber, on request
CRI (Ra)> 70, optionally 80 or 90
Color consistency3-step MacAdam ellipse
Sustainability and size
Company temperature-45 to +50 °C
LED lifespanTM-21 L90B05, 103,500 hours
Power factor and frequency0.99 at 50 or 60 Hz
Dimensions905 × 550 × 160 mm
CertificationCE, IEC 60598, EMC
Warranty5 years, expandable to 10

One Three replaces multiple traditional floodlights, without a single lumen of stray light. For the largest sites and high mast applications. When choosing, pay attention to the load-bearing capacity of the structure: 35 kg per fixture, plus wind load.

Light image

The cut-off determines where the light ends

With a standard floodlight, you choose a lens and that fixes the beam. Here, you set the cut-off: the angle above which no more light comes out of the fixture. That choice follows from the mounting height, the shape of the site, and how sensitive the surroundings are, and it can be changed on-site, even after the pole is installed.

On top of that, the square reflector modules can be rotated 90 degrees in both directions. This allows you to tilt the light distribution per position to match the shape of the terrain without having to choose a different fixture.

Product rendering of the DarkLicht 1200-watt floodlight mounted on a light pole
Cut-offWhat for
75°Maximum forward shielding, for low mounting heights.
72°The standard mode: the best balance between forward light and uniformity.
69°For the highest possible uniformity across the plane.
66°For lighting from extreme heights, above 50 meters.
63°For the strictest DarkSky zones, in combination with the lowest color temperatures, 1700 or 1800 K.

Which angle belongs to your position follows from the lighting calculation. We make this free of charge, including the assessment against the NSVV light nuisance guideline or your environmental permit, see lighting advice and lighting calculation.

More than a fixture

The system around it determines the end result

With large installations, the difference lies not in the fixture but in the power supply, the mounting, and the configuration. That is why we supply the DarkLicht as a system.

Render of a 600x800 crane bracket with LED floodlights

Crane frame DL-CCB-400+DIS

Hot-dip galvanized frame with a robust pin system, compatible with all brands of tower cranes. Holds up to four DarkLicht assemblies, including distribution, and is stackable for transport and storage. See tower crane lighting.

DRB-driverbox

From the DL1-600 onwards, the driver is external, housed in an industrial driver box made of the same aluminum with titanium e-coating as the fixtures: IP67, optionally IP68, IK08, driver lifespan exceeding 130,000 hours, and a power factor above 0.95. The DRB-1 up to 200 W, the DRB-2 up to 2,000 W; one DRB-2 powers up to four fixtures.

The fact that the driver is located outside the fixture has two practical consequences: the fixture remains lighter on the pole, and the driver can be replaced without dismantling the fixture. At a height of fifty meters, that saves a crane.

Mast and assembly solutions

From fixed masts to mobile setups, tailored to mounting height and cut-off. See light masts and high masts and the mobile light mast.

Light calculation and nuisance test

Every DarkLicht installation is supported by a lighting calculation: number of fixtures, positions, cut-off angle, expected illuminance in lux, and compliance with the NSVV guideline or the permit. This service is provided free of charge, even if you use the plan elsewhere.

Applications

Where the light must remain within the property boundary

Tower crane at night with sustainable LED lighting

Tower cranes and construction sites

Using the DL-CCB-400+DIS crane frame, the DarkLicht illuminates the entire construction site from the boom, in compliance with DarkSky standards, as seen at the HSB construction site in Hilversum. No complaints from the neighborhood, yet a full view of the work.

Aerial photograph of the illuminated P&O Ferries terminal at night

Harbors and terminals

At DFDS in Vlaardingen, the switch resulted in a 53 percent saving: the site lit, the surroundings dark. BUSS Terminal Eemshaven and P&O Ferries chose the same approach.

Light pole with LED floodlights at the Verbrugge terminal

Construction and infrastructure

Where the NSVV guideline on light nuisance and the environmental permit set the framework, the lighting determines whether work may continue at night. Fully shielded light, dimmable for the night hours.

FC Volendam stadium field at night with LED lighting

Sports Fields and Stadiums

For sports facilities that want to limit nuisance to local residents and nature, such as RKAV Volendam. Uniform match lighting on the pitch, no spill light into the neighborhood, and optionally 2200 K amber along a nature reserve.

Product family

The DarkLicht Line in Perspective

The same reflector technology in eight sizes, from 4,800 to 307,800 lumens. One, Two, and Three are the fixed area floodlights for site and mast; the M is the version for cranes and mobile masts; the D and the WP are the simple outdoor luminaires; the S and the Mini are the work lights for machinery. Only the WP and the 320 W version are at 160 lm/W, the rest at 171.

LuminaireLuminous fluxPowerToe the lineWeight
DarkLight Three307,800 lm1,800 Wlargest sites, high mast35.0 kg
DarkLight Two136,800 to 205,200 lm800 to 1,200 Wterminals in industrial areas24.8 kg
DarkLight One51,200 to 102,600 lm320 to 600 Wmedium-sized grounds and sports fields14.0 to 15.0 kg
DarkLicht M25,700 to 51,300 lm150 to 300 Wcranes and mobile light towers3.6 to 5.5 kg
DarkLicht D10,300 to 34,200 lm60 to 200 Wparking and industrial areas6.9 to 8.5 kg
DarkLicht WP wallpack9,600 to 16,000 lm60 to 100 Wfacades and entrances4.0 kg
DarkLicht S10.260 to 12.825 lm60 to 75 Wwork light on machinery3.3 kg
DarkLicht Mini4,800 lm30 Wcompact work lamp2.2 lbs
Dimensioning

Dimensions and downloads

The three sizes share the same height and depth: 550 by 160 mm. Only the width and weight increase with the number of reflector modules. The bracket is made of high-grade 316L stainless steel; the complete bolt pattern is listed in the datasheet.

ModelDimensionsWeight
One365 × 550 × 16014.0 to 15.0 kg
Two635 × 550 × 16024.8 kg
Three905 × 550 × 16035.0 kg

Dimensions in mm, width × height × depth.

The datasheet is a direct download, without a form. For the 3D and IES file, we ask about your situation.

Technical drawing showing the dimensions of the DarkLicht DL-O1
Technical drawing showing the dimensions of the DarkLicht DL-O2
Technical drawing showing the dimensions of the DarkLicht DL-O3
Installation

Connect and integrate into the installation

The DarkLicht operates on 180 to 528 volts AC and is therefore intended for phase-to-phase and high-voltage connections; a version for 250 to 740 volts DC is optional, and a 24-volt DC variant of the DL1-600 is available. The DL1-320 and DL1-400 have an internal driver, while the larger models have an external driver housed in a DRB box. Dimming is standard via 0–10 V, with DALI available as an option; this allows for the configuration of a night mode or a schedule, which is the standard method for further reducing energy consumption and light pollution outside of operating hours.

Voltage range180 to 528 VAC
Optional250 to 740 VDC, or 24 VDC for DL1-600
Labor factor0.99
Mains frequency50 or 60 Hz
Dim0-10 V, optional DALI
Questions

Frequently Asked Questions About the DarkLicht

Don't see your question listed? Call us, and we'll walk through your site in five minutes.

Light control. A conventional floodlight uses lenses or an open optical system, which means that some of the light is always lost as glare and scattered light. The DarkLicht uses patented parabolic reflectors: above the adjustable cutoff, light output is zero—both forward and backward. All the light is directed onto the surface to be illuminated, which is why fewer fixtures are often needed to achieve the same level of illumination.

Yes. Because no light escapes above the cutoff, the upward light emission is zero, which means that the DarkLicht at low color temperatures (2200 K, 1800 K, or 1700 K) meets the strictest DarkSky specifications, including DS-1. With proper lighting design, the limits set by the NSVV light pollution guideline are also met in virtually all classes, even at high power levels. We substantiate this for each project with a lighting calculation.

That follows from the mounting height, the dimensions of the site and the sensitivity of the surroundings. As a rule of thumb: 75 degrees for low mounting, 72 degrees as standard, 69 degrees for maximum uniformity, 66 degrees from extreme heights above 50 meters, and 63 degrees in the strictest DarkSky zones, combined with 1700 or 1800 K. We substantiate the final choice with a lighting calculation, including the number of luminaires, the positions and the expected illuminance in lux.

CE and IEC 60598, along with the corresponding EMC standards. In addition, the luminaire is designed to comply with the NSVV light pollution guideline and, at low color temperatures, with the most stringent DarkSky specifications, including DS-1. For workplace lighting, the DarkLicht supports compliance with EN 12464-2, and for sports facilities, with EN 12193. For specific project requirements, we assess the certification status on a per-application basis.

No. There is no type approval from DNV, Lloyd's, Bureau Veritas, or any other classification society. If your specification requires this, we state this in advance and provide the documentation that is available.

The drivers are equipped with surge protection; the exact value depends on the chosen driver configuration and the DRB box. When making your request, please indicate if a specific requirement applies, for example from a terminal standard or an insurer, and we will confirm the value with the quotation.

That depends on the power, voltage, and cable route. For a line of poles on a site, the voltage drop is usually the limiting factor, not the circuit breaker. Provide the number of poles, the power per pole, and the cable route, and we will calculate it and provide the load table with the plan.

The type designations are DL1, DL2, and DL3, followed by the wattage; the DC version of the One is called DL-O1-600DC and the crane frame DL-CCB-400+DIS. The cut-off position and light color are specified separately when ordering, as these follow from the lighting calculation rather than the product selection. The complete order codes can be found in the article classification. The HS code for the luminaires is 9405500090.

The M is the glare-free version for cranes, machinery, and mobile light towers: 150 to 300 W, 25,700 to 51,300 lumens, IP69K, and 3.6 to 5.5 kg. The large DarkLicht is the fixed floodlight for site and mast lighting: 320 to 1,800 W, up to 307,800 lumens per fixture, with external drivers in DRB boxes starting at 1,200 W.

The D is a simple outdoor floodlight ranging from 60 to 200 W with an internal driver, delivering 10,300 to 34,200 lumens, designed for parking lots, construction sites, and industrial grounds on poles ranging from four to twelve meters. The large DarkLicht picks up where the D leaves off: larger areas, taller masts, and power ratings up to 1,800 W, supplied as a system with driver boxes and lighting calculations.

Yes, that is a core application. Even pitch lighting across the field without stray light towards homes or nature, as at RKAV Volendam. In doing so, we calculate according to EN 12193, the standard for sports lighting, which sets requirements for illuminance and uniformity per level. For match visibility, 4000 to 5000 K is often chosen; if the field borders a nature reserve, 2200 K or lower is possible.

Yes. The aluminum housing contains less than 0.08 percent copper to minimize galvanic corrosion and features a two-layer titanium e-coating; the bracket is made of high-grade 316L stainless steel. This makes the fixture suitable for ports, coastal locations, and industrial sites. For extremely corrosive environments, 316L versions are available within the DarkLicht family; please inquire about the options for each model.

Copper in aluminum accelerates galvanic corrosion as soon as the aluminum comes into contact with stainless steel or seawater. By deliberately keeping the copper content below 0.08 percent, that corrosion chain is broken. In combination with the 316L bracket and the titanium e-coating, the luminaire maintains its structural integrity, even during prolonged exposure to salt.

Yes. The luminaire is IP67 rated and therefore completely dust- and waterproof for permanent outdoor use, featuring thermally toughened glass on the front and IK07 impact resistance. Periodic cleaning with a soft cloth or a low-pressure water jet is sufficient; the reflector itself is protected behind the glass.

The luminaire itself has no wearing parts. The external drivers in the DRB boxes are separately accessible and can be replaced without disassembling the luminaire; on a high mast, that is the difference between a service call and a crane. The recommended inspection is limited to periodically cleaning the glass and checking the mounting and cable entries.

The specified 103,500 hours is an L90B05 value: at that point, at least 95 percent of the luminaires still deliver at least 90 percent of the original luminous flux. That is a stricter measure than the common L70 and L80 specifications in the market. With continuous use of 24 hours a day, 103,500 hours amounts to well over eleven years. In practice, the LED is rarely the limiting factor; environmental load, temperature, corrosion, and installation quality determine the actual service life.

Request

Have your property evaluated

Provide the surface area, mast height, and surroundings. We determine the size, One, Two, or Three, the cut-off position, the light color, the driver configuration, and the mounting solution, supported by a lighting calculation and a glare assessment.

Your request is being reviewed by an engineer. We will respond within 1 business day.

Responsewithin 1 working day, by an engineer
Light calculationfree of charge, with hindrance assessment
Test fixturepossibly, in your own position
Warranty5 years, expandable to 10
Prefer direct contact?

dwg, dxf, pdf, jpg or png · maximum 5 files · 15 MB. We use your data exclusively to assess your request.