One canopy shape for every canopy: 22,400 lumens at 224 lm/W, dimmable with 0-10V, PWM, DALI-2, or NFC.
Available as a recessed or surface-mounted fixture, and as a 21-mm-thick retrofit panel that fits perfectly into an existing CREE 304 mounting location. New is the Manta HT: the same design, built for environments up to +120 °C, for drying tunnels, steam-cleaning car washes, and hot process rooms where no ceiling fixture was previously available.
A response from an engineer within 1 business day. Free lighting analysis and comparison with your current system.
Manta canopy lights in a gas station canopy.
100 W, 224 lm/W
Adjustable via NFC, HT 10–75 W
IK08, diffuse tempered glass or borosilicate
built-in, 3.9 kg
limited, including on the HT
from −45 °C to +120 °C with the HT
This is a light fixture designed to be mounted underneath something: an awning, a ceiling, or a canopy. It doesn't illuminate an outdoor area but rather a living space.
As soon as there is nothing above the fixture, or as soon as a distance needs to be bridged, a floodlight or a vlakstraler is the more logical choice.
All versions share the same square dimension; what differs is the installation depth, the weight, and in the case of the HT, the entire thermal design. In the standard versions, the driver is located internally, while in the HT it is external, outside of the hot zone.
built-in, 380 × 380 × 21 mm
Blends seamlessly into the canopy or suspended ceiling for a seamless final appearance. The logical choice for new construction and renovation where ceiling integration matters. 3.9 kg.
MNAC02
surface-mounted, 380 × 380 × 70 mm
Mounted directly to the ceiling or substructure, without a recess. For existing ceilings without installation space, steel structures, parking decks, and drive-through zones. 4.9 kg.
MNAC01
surface-mounted, 380 × 380 × 118 mm
The extended surface-mounted version, and at the same time the retrofit panel: this version fits into an existing CREE 304 cutout, so the canopy ceiling can remain closed. Same light engine, 5.4 kg.
article code MNAC03
up to +120 °C, external driver
For drying tunnels, car washes with steam cleaning, and hot process rooms. Chemically toughened glass, heat-resistant silicone cable, and an external driver outside the hot zone. Optionally with infrared-reflective print.
MNHT02
up to +120 °C, external driver
Same HT structure, mounted directly to the ceiling or substructure. For hot zones without installation space, or where the ceiling must not be penetrated.
MNHT01
The Manta hangs under a canopy or ceiling. If it concerns a linear arrangement, a facade, or a site, the answer is elsewhere in the program.
| Luminaire | Role in the range | Mounting position |
|---|---|---|
Manta canopy22,400 lumens | The canopy for under an awning, ceiling, or canopy. Recessed, surface-mounted, and retrofit from a single line, also up to +120 °C. | ceiling and awning |
Linear25,600 lumens | Linear industrial lighting for continuous runs along corridors, machinery, and walkways. | ceiling and wall |
DarkLicht WP wallpack16,000 lumens | Wall-mounted fixture with a full cut-off reflector that directs the light forward, with no upward light. | facade |
DarkLicht D34,200 lumens | Full-cut-off floodlight for outdoor areas and parking lots where light pollution must be actively minimized. | mast and structure |
Choose a trim level and the complete specification list below changes accordingly: the three standard trim levels and the two HT trim levels. Image, key figures, and specifications all update at once, without a second tab.
Item number
The recessed version is installed flush with the ceiling.
22,400 lm
| Luminous flux | 22,400 lm |
| With optics | 20,600 lm with optics |
| Efficiency | 224 lm/W |
| Power consumption | 100 W |
| Beam angles | no standard optics, or 30°, 60° or 120° |
| Bundle and field angle | 136° / 168° without optics · 36° / 58° with the 30° optics |
| Color temperatures | 5700K, 5000K, 4000K, 3000K, 2700K and amber 2200K |
| Tunable white | 4000K with 2200K and 1700K, switchable during operation |
| Bi-color | cool white with amber |
| CRI (Ra) | > 70, or optionally 80 or 90 |
| Color consistency | 3-step MacAdam |
| ULOR | 0 % at 0° tilt |
| Voltage range | 90 to 305 VAC, 50/60 Hz |
| Current draw | approx. 0.83 A at 120 V · 0.45 to 0.36 A at 220 to 277 V |
| DC power supply | Not available for this model |
| Dimming | 0-10 V, PWM, DALI-2 or via NFC |
| Driver | internal |
| Driver Type | BLD120, in the housing |
| Surge protection | 6 kV line-to-line, 10 kV line-to-ground (IEC 61000-4-5) |
| Power factor | > 0.9 at 70 to 100 % load |
| Cable type | H07BQ-F, 4-core (2 × 1.5 mm² + 2 × 0.5 mm²), 0.3 m |
| Connection | pre-assembled, bare wires |
| Housing | cast aluminum, < 0.08 % copper |
| Surface treatment | conversion layer with 2-layer titanium e-coating |
| Bracket | fixed bracket, aluminum, < 0.08 % copper |
| Front | diffuse chemically strengthened glass or diffuse borosilicate, IK08 |
| Color | Neutral White |
| Dimensions | 380 × 380 × 21 mm |
| Weight | 3.9 kg |
| Lead time | Standard within a week, custom by arrangement |
| Packaging | on request |
| IP Ratings | IP66, IP67, IP68, and IP69K, each tested individually |
| Impact Resistance | IK08 (IEC 62262) |
| Protection Class | Class II |
| Corrosion class | C5 Industrial and Maritime (ISO 9223) |
| Vibration class | 6 G at resonance (IEC 60068-2-6), shock IEC 60068-2-27 |
| Operating temperature | −45 to +50 °C |
| LED lifespan | TM-21 L90B05, > 103,500 hours at +50 °C |
| Driver lifespan | ≥ 100,000 hours at Tc 75 °C |
| MTBF driver | ≥ 320,000 hours at Tc 75 °C |
| Driver Temperature | Temperature: −40 to +90 °C |
| Warranty | 5 years on the complete luminaire |
| Certification | CE, IEC/EN 60598-1 and -2-5, EN 55015, and EN 61547. EMC tested by TÜV; IEC 60533 for marine applications. |
Item number
The surface-mounted version, to be installed without a recess.
22,400 lm
| Luminous flux | 22,400 lm |
| With optics | 20,600 lm with optics |
| Efficiency | 224 lm/W |
| Power consumption | 100 W |
| Beam angles | no standard optics, or 30°, 60° or 120° |
| Bundle and field angle | 136° / 168° without optics · 36° / 58° with the 30° optics |
| Color temperatures | 5700K, 5000K, 4000K, 3000K, 2700K and amber 2200K |
| Tunable white | 4000K with 2200K and 1700K, switchable during operation |
| Bi-color | cool white with amber |
| CRI (Ra) | > 70, or optionally 80 or 90 |
| Color consistency | 3-step MacAdam |
| ULOR | 0 % at 0° tilt |
| Voltage range | 90 to 305 VAC, 50/60 Hz |
| Current draw | approx. 0.83 A at 120 V · 0.45 to 0.36 A at 220 to 277 V |
| DC power supply | Not available for this model |
| Dimming | 0-10 V, PWM, DALI-2 or via NFC |
| Driver | internal |
| Driver Type | BLD120, in the housing |
| Surge protection | 6 kV line-to-line, 10 kV line-to-ground (IEC 61000-4-5) |
| Power factor | > 0.9 at 70 to 100 % load |
| Cable type | H07BQ-F, 4-core (2 × 1.5 mm² + 2 × 0.5 mm²), 0.3 m |
| Connection | pre-assembled, bare wires |
| Housing | cast aluminum, < 0.08 % copper |
| Surface treatment | conversion layer with 2-layer titanium e-coating |
| Bracket | fixed bracket, aluminum, < 0.08 % copper |
| Front | diffuse chemically strengthened glass or diffuse borosilicate, IK08 |
| Color | Neutral White |
| Dimensions | 380 × 380 × 70 mm |
| Weight | 4.9 kg |
| Packaging | on request |
| IP Ratings | IP66, IP67, IP68, and IP69K, each tested individually |
| Impact Resistance | IK08 (IEC 62262) |
| Protection Class | Class II |
| Corrosion class | C5 Industrial and Maritime (ISO 9223) |
| Vibration class | 6 G at resonance (IEC 60068-2-6), shock IEC 60068-2-27 |
| Operating temperature | −45 to +50 °C |
| LED lifespan | TM-21 L90B05, > 103,500 hours at +50 °C |
| Driver lifespan | ≥ 100,000 hours at Tc 75 °C |
| MTBF driver | ≥ 320,000 hours at Tc 75 °C |
| Driver Temperature | Temperature: −40 to +90 °C |
| Warranty | 5 years on the complete luminaire |
| Certification | CE, IEC/EN 60598-1 and -2-5, EN 55015, and EN 61547. EMC tested by TÜV; IEC 60533 for marine applications. |
Item number
The surface-mounted version with an extended housing.
22,400 lm
| Luminous flux | 22,400 lm |
| With optics | 20,600 lm with optics |
| Efficiency | 224 lm/W |
| Power consumption | 100 W |
| Beam angles | no standard optics, or 30°, 60° or 120° |
| Bundle and field angle | 136° / 168° without optics · 36° / 58° with the 30° optics |
| Color temperatures | 5700K, 5000K, 4000K, 3000K, 2700K and amber 2200K |
| Tunable white | 4000K with 2200K and 1700K, switchable during operation |
| Bi-color | cool white with amber |
| CRI (Ra) | > 70, or optionally 80 or 90 |
| Color consistency | 3-step MacAdam |
| ULOR | 0 % at 0° tilt |
| Voltage range | 90 to 305 VAC, 50/60 Hz |
| Current draw | approx. 0.83 A at 120 V · 0.45 to 0.36 A at 220 to 277 V |
| DC power supply | Not available for this model |
| Dimming | 0-10 V, PWM, DALI-2 or via NFC |
| Driver | internal |
| Driver Type | BLD120, in the housing |
| Surge protection | 6 kV line-to-line, 10 kV line-to-ground (IEC 61000-4-5) |
| Power factor | > 0.9 at 70 to 100 % load |
| Cable type | H07BQ-F, 4-core (2 × 1.5 mm² + 2 × 0.5 mm²), 0.3 m |
| Connection | pre-assembled, bare wires |
| Housing | cast aluminum, < 0.08 % copper |
| Surface treatment | conversion layer with 2-layer titanium e-coating |
| Bracket | fixed bracket, aluminum, < 0.08 % copper |
| Front | diffuse chemically strengthened glass or diffuse borosilicate, IK08 |
| Color | Neutral White |
| Dimensions | 380 × 380 × 118 mm |
| Weight | 5.4 kg |
| Packaging | on request |
| IP Ratings | IP66, IP67, IP68, and IP69K, each tested individually |
| Impact Resistance | IK08 (IEC 62262) |
| Protection Class | Class II |
| Corrosion class | C5 Industrial and Maritime (ISO 9223) |
| Vibration class | 6 G at resonance (IEC 60068-2-6), shock IEC 60068-2-27 |
| Operating temperature | −45 to +50 °C |
| LED lifespan | TM-21 L90B05, > 103,500 hours at +50 °C |
| Driver lifespan | ≥ 100,000 hours at Tc 75 °C |
| MTBF driver | ≥ 320,000 hours at Tc 75 °C |
| Driver Temperature | Temperature: −40 to +90 °C |
| Warranty | 5 years on the complete luminaire |
| Certification | CE, IEC/EN 60598-1 and -2-5, EN 55015, and EN 61547. EMC tested by TÜV; IEC 60533 for marine applications. |
Item number
The high-temperature recessed version, up to +120 °C with an external driver.
14,400 lm
| Luminous flux | 14,400 lm |
| With optics | no lenses possible |
| Efficiency | 192 lm/W |
| Power consumption | 75 W |
| Beam angles | 120° very wide, no optics possible |
| Bundle and field angle | 136° / 168° |
| Color temperatures | 6500K, 4000K, and 2700K |
| Tunable white | not available on the HT versions |
| Bi-color | not available on the HT versions |
| CRI (Ra) | > 70, or optionally 80 or 90 |
| Color consistency | 3-step MacAdam |
| ULOR | 0 % at 0° tilt |
| Voltage range | 90 to 305 VAC, 50/60 Hz |
| Current draw | approx. 0.63 A at 120 V · 0.34 to 0.27 A at 220 to 277 V |
| DC power supply | 127 to 420 VDC, warranty up to +110 °C |
| Dimming | 0-10 V, PWM, DALI-2 or via NFC |
| Driver | external, outside the hot zone |
| Driver Type | BLD120, 90 to 305 VAC or 127 to 420 VDC |
| Driverbox | DRB-1, 276 × 194 × 86.5 mm, 4.2 kg, IP66 and IP67 |
| Surge protection | 6 kV line-to-line, 10 kV line-to-ground (IEC 61000-4-5) |
| Power factor | > 0.9 at 70 to 100 % load |
| Cable type | SiHF-OB silicone cable, 4 conductors (2 × 2.5 mm² + 2 × 0.5 mm²), 5.0 m |
| Connection | pre-assembled, bare wires |
| Self-protection | Internal temperature feedback via two control pins; dims and shuts off in case of overheating |
| Housing | cast aluminum, < 0.08 % copper |
| Surface treatment | conversion layer with 2-layer titanium e-coating |
| Bracket | fixed bracket, aluminum, < 0.08 % copper |
| Front | diffuse chemically strengthened glass or diffuse borosilicate, IK08 |
| Color | Titanium light gray |
| Dimensions | 380 × 380 × 21 mm |
| Weight | 3.9 kg |
| Packaging | on request |
| IP Ratings | IP66, IP67, IP68, and IP69K, resistant to steam and high-pressure cleaning |
| Impact Resistance | IK08 (IEC 62262) |
| Protection Class | Class II |
| Corrosion class | C5 Industrial and Maritime (ISO 9223) |
| Vibration class | 6 G at resonance (IEC 60068-2-6), shock IEC 60068-2-27 |
| Operating temperature | -45 to +120 °C, peaks up to +130 °C |
| Driverbox Environment | up to +50 °C |
| LED lifespan | TM-21 L90B05: 360,000 hours at +50 °C · 103,000 at +85 °C · 71,700 at +105 °C · 51,400 at +120 °C |
| Driver lifespan | ≥ 100,000 hours at Tc 75 °C |
| MTBF driver | ≥ 320,000 hours at Tc 75 °C |
| Driver Temperature | Temperature: −40 to +90 °C |
| Warranty | 5-year warranty on the entire fixture up to +120 °C on AC, up to +110 °C on DC |
| Certification | CE, IEC/EN 60598-1 and -2-5, EN 55015, and EN 61547. EMC tested by TÜV; IEC 60533 for marine applications. |
Item number
The surface-mount high-temperature version, up to +120 °C with an external driver.
14,400 lm
| Luminous flux | 14,400 lm |
| With optics | no lenses possible |
| Efficiency | 192 lm/W |
| Power consumption | 75 W |
| Beam angles | 120° very wide, no optics possible |
| Bundle and field angle | 136° / 168° |
| Color temperatures | 6500K, 4000K, and 2700K |
| Tunable white | not available on the HT versions |
| Bi-color | not available on the HT versions |
| CRI (Ra) | > 70, or optionally 80 or 90 |
| Color consistency | 3-step MacAdam |
| ULOR | 0 % at 0° tilt |
| Voltage range | 90 to 305 VAC, 50/60 Hz |
| Current draw | approx. 0.63 A at 120 V · 0.34 to 0.27 A at 220 to 277 V |
| DC power supply | 127 to 420 VDC, warranty up to +110 °C |
| Dimming | 0-10 V, PWM, DALI-2 or via NFC |
| Driver | external, outside the hot zone |
| Driver Type | BLD120, 90 to 305 VAC or 127 to 420 VDC |
| Driverbox | DRB-1, 276 × 194 × 86.5 mm, 4.2 kg, IP66 and IP67 |
| Surge protection | 6 kV line-to-line, 10 kV line-to-ground (IEC 61000-4-5) |
| Power factor | > 0.9 at 70 to 100 % load |
| Cable type | SiHF-OB silicone cable, 4 conductors (2 × 2.5 mm² + 2 × 0.5 mm²), 5.0 m |
| Connection | pre-assembled, bare wires |
| Self-protection | Internal temperature feedback via two control pins; dims and shuts off in case of overheating |
| Housing | cast aluminum, < 0.08 % copper |
| Surface treatment | conversion layer with 2-layer titanium e-coating |
| Bracket | fixed bracket, aluminum, < 0.08 % copper |
| Front | diffuse chemically strengthened glass or diffuse borosilicate, IK08 |
| Color | Titanium light gray |
| Dimensions | 380 × 380 × 70 mm |
| Weight | 4.9 kg |
| Packaging | on request |
| IP Ratings | IP66, IP67, IP68, and IP69K, resistant to steam and high-pressure cleaning |
| Impact Resistance | IK08 (IEC 62262) |
| Protection Class | Class II |
| Corrosion class | C5 Industrial and Maritime (ISO 9223) |
| Vibration class | 6 G at resonance (IEC 60068-2-6), shock IEC 60068-2-27 |
| Operating temperature | -45 to +120 °C, peaks up to +130 °C |
| Driverbox Environment | up to +50 °C |
| LED lifespan | TM-21 L90B05: 360,000 hours at +50 °C · 103,000 at +85 °C · 71,700 at +105 °C · 51,400 at +120 °C |
| Driver lifespan | ≥ 100,000 hours at Tc 75 °C |
| MTBF driver | ≥ 320,000 hours at Tc 75 °C |
| Driver Temperature | Temperature: −40 to +90 °C |
| Warranty | 5-year warranty on the entire fixture up to +120 °C on AC, up to +110 °C on DC |
| Certification | CE, IEC/EN 60598-1 and -2-5, EN 55015, and EN 61547. EMC tested by TÜV; IEC 60533 for marine applications. |
Instant download, no form required. All the values listed above are also included in the datasheet.
The luminaire is supplied with a pre-assembled connection cable with free leads: 0.3-meter H07BQ-F with four leads for the standard versions, 5-meter heat-resistant SiHF-OB silicone cable for the HT.
also 120 V, internal driver
at 220 to 277 V · 0.83 A at 120 V
at 220 to 277 V · 0.63 A at 120 V
PWM or via NFC, per position
The light level is controlled via 0-10 V, PWM, or DALI-2, and,via NFC,also using a phone or programming box, without opening the fixture or disconnecting the power. For a canopy with multiple zones, you can set a different light level for each position and adjust them later if the layout changes: a position above the pumps can be set higher than one above the passageway.
With the standard versions, the driver is internal and the fixture operates directly from 90 to 305 volts. With the HT, the driver is external and remains outside the hot zone: drivers are more sensitive to heat than the LED module itself, and this makes maintenance possible without entering the hot room. We will calculate your canopy free of charge: see lighting advice and lighting calculation.
Under a canopy, the beam angle determines whether the edge of the canopy still receives light. The standard models are available with 30°, 60°, or 120° angles; the HT model has a fixed 120° angle. If you’re unsure between two angles, we’ll help you make the right choice with a free lighting calculation.
Directed beam for a high canopy or a narrow passageway. All three recessed depths share the same optical platform and photometry.
The center distribution for most awnings: even, with no bright spot in view.
Wide distribution for low canopies and covered walkways, and the fixed distribution of the HT version.
| Optics | Luminous flux | Version | Application |
|---|---|---|---|
| 30° | 20,600 lm | standard | Directed beam, 36° beam angle and 58° field angle. High canopies and narrow zones, with optics approx. 206 lm/W. |
| 60° | 20,600 lm | standard | Center divider, the standard choice under a gas station canopy. |
| 120° | 20,600 lm | standard | Very wide, for low awnings and close positions. |
| Without optics | 22,400 lm | standard | The standard version: 136° beam angle and 168° field angle, the luminous flux of the light engine itself at 224 lm/W. |
| 120°, fixed, HT | 14,400 lm | HT | No lenses possible: the housing is too shallow to wear any. |
The light engine has a luminous flux of 22,400 lumens; 20,600 lumens is the output with optics; each lens reduces the light output. As a result, the efficiency ranges from 224 lm/W without specific optics to approximately 206 lm/W with optics. We base our calculations on the value corresponding to your chosen optics. With the HT model, lenses are not possible due to the high temperatures.
The CREE 304 is used worldwide and hangs at thousands of service stations. Anyone replacing that installation normally runs into the same problem: the new luminaire does not fit into the existing cutout, which leaves you stuck with demolition work, new cabling, and a second visit.
The Manta Surface Extended is designed for just that: 118 mm deep, 5.4 kg, and it fits into an existing CREE 304 cutout. No new cutout, no new wiring.
| No demolition work | The panel fits into the existing cutout, so the ceiling of the canopy remains closed and no repair work is required. |
| No new cabling | The existing connection will remain in use. That not only saves material, but above all a second visit from the installer. |
| Minimal downtime per canopy | For a chain with many locations, that counts double: every position that remains closed longer than necessary costs revenue. |
| Dimmable per position | Dimming via 0-10V, PWM, DALI-2 or NFC, even after the panel is installed. A position above the pumps can be set higher than a position above the drive-through. |
from the panel
per luminaire
We calculate your awning free of charge and include the comparison with the existing situation. Send a photo of the current position, and we will confirm the fit in advance.
Until now, ceiling fixtures were rarely installed in drying tunnels or steam-cleaning car washes, simply because none existed that could withstand the conditions. The Manta HT has the same shape and the same 380 by 380 millimeter dimensions, but a different thermal design: chemically tempered glass or borosilicate on the front, a 5-meter heat-resistant SiHF-OB silicone cable, and an external driver that remains outside the hot zone.
In heat, lifespan is not a number but a curve, and we prefer to write that down rather than name a single value. Next to this is the specification per ambient temperature, measured according to TM-21 and reported as L90B05, equal to the rest of the program.
Due to the high temperatures, lenses are not possible: the HT has a single beam angle of 120 degrees, very wide, with a field angle of 168 degrees. If you want a narrower beam in a hot zone, a floodlight from the high-temperature line the correct route.
| Ambient Temperature | Service Life L90B05 |
|---|---|
| +50 °C | 360,000 hours |
| +85 °C | 103,000 hours |
| +105 °C | 71,700 hours |
| +120 °C | 51,400 hours |
Even 51,400 hours is still well over fourteen years at ten burning hours a day. See also High-temperature lighting.
A canopy does not illuminate an area but rather a place to stay. People stand there quietly, look up, and subconsciously assess whether it feels safe. This imposes different requirements than outdoor lighting: the light must be even, with no bright source in view, and without a dark edge along the outer edge of the canopy.
The core application, and the place where the CREE 304 is most frequently installed. High light output, neat ceiling integration, and years of reliable operation above an area where you cannot simply place a cherry picker.
Covered outdoor areas where functional and uniform light is required in a dust- and waterproof design. Outdoor in terms of load capacity, indoor in terms of light distribution: wet and dirty, but out of direct rain.
At fast chargers, people linger longer than at a fuel pump, often alone and in the dark. Good ceiling lighting directly determines how safe it feels here, and the power output per position can be adjusted to suit the zone.
With the HT version also in drying tunnels, drying lines, car washes with steam cleaning, and hot zones in the food and paper industries. Up to +120 °C, with the driver outside the hot zone.
All dimensions in millimeters. All versions share the same 380 by 380 square; only the installation depth and weight differ. DXF and STEP files are available upon request.
Cable length: 0.3 m for standard models, 5.0 m silicone cable for the HT model; longer lengths available upon request. Packaging dimensions available upon request; packaging size and weight are included in the quote, as JEL handles shipping.
| Version | Dimensions | Weight |
|---|---|---|
| Manta Ray Sanctuary | 380 × 380 × 21 mm | 3.9 kg |
| Manta Surface | 380 × 380 × 70 mm | 4.9 kg |
| Manta Surface Extended | 380 × 380 × 118 mm | 5.4 kg |
| Manta HT, built-in | 380 × 380 × 21 mm | 3.9 kg |
| Manta HT, surface-mounted | 380 × 380 × 70 mm | 4.9 kg |
Bottom view. Dimensions and mounting pattern are on the datasheet.
Every claim carries its condition in the same sentence. You can read more about the test methods at Product Quality and Warranty.
IP69K means completely dust- and waterproof, including cleaning with a high-pressure jet at close range. Under a canopy, that is not excessive: water and foam are used at a car wash or gas station, and the canopy hangs right in the middle of it. IK08 is the impact resistance of the front, made of diffuse chemically hardened glass or diffuse borosilicate.
L90B05 for standard models: at that point, at least 95 % of the fixtures will still deliver at least 90 % of their initial light output. For the HT model, the rated lifespan ranges from 360,000 hours at +50 °C to 51,400 hours at +120 °C.
The Manta Surface Extended fits perfectly into an existing CREE 304 mounting position: no new cutout, no new wiring, and minimal downtime per location.
The full specification per version, with dimensions and order code. Direct download, no form.
STEP or DXF for your own drawing, including the assembly pattern and the cutout.
All 8 versions and optics of the Manta in EULUMDAT (.ldt) format, combined into a single 0.8 MB ZIP file. DIALux and Relux can read these files directly. The part number is included in the file name and within the file itself. We provide IES files upon request.
Installation, wiring, mounting, maintenance and fault finding for the Manta Series in one document of 38 pages, Rev. 1. Download directly in the language of this page.
Also in: Nederlands · English · Deutsch · Français · Español
Can't find your question? Call us with the number of positions and the awning height at hand, and you will know what is needed within five minutes. An engineer will respond within 1 business day.
Yes. That’s what the Manta Surface Extended is designed for: the same 380 by 380 millimeters, 118 mm deep, and 5.4 kg, and it fits into an existing CREE 304 cutout. No new cutout, no new wiring. That’s where you save the most money on a retrofit, because if the awning ceiling can remain closed, there’s no need for cutting or breaking work—and no need for a second visit. The part number for this retrofit version is MNAC03; please send a photo of the current situation, and we’ll confirm the fit in advance.
22,400 lumens is the luminous flux of the light engine, and 20,600 lumens is what comes out with optics. That difference is normal, because every lens absorbs light. The efficiency therefore ranges from 224 lm/W without specific optics to approximately 206 lm/W with optics. We calculate using the value that corresponds to your chosen optic.
That depends on the ceiling. If there is recessed space and you want a seamless finish, then the Recess. If there is no recessed space or it concerns a steel structure, then the Surface. If the luminaire needs to extend further below the ceiling, then the Surface Extended. If you are replacing a CREE 304, then the Surface Extended. And if the environment is warmer than +50 °C, then the HT.
The mounting depth and the weight. The Surface is 70 mm deep and weighs 4.9 kg, the Surface Extended 118 mm and 5.4 kg. Furthermore, they are identical: the same 380 by 380 mm, the same 22,400 lumens, and the same electronics. The Extended is intended for situations where the luminaire needs to extend further below the ceiling.
As soon as the ambient temperature structurally exceeds +50 °C: drying tunnels, drying lines, car washes with steam cleaning, and hot process rooms in the food and paper industries. The HT works up to +120 °C, with chemically tempered glass, a heat-resistant 5-meter SiHF-OB silicone cable, and an external driver outside the hot zone.
That depends on the temperature, and we prefer to write that down rather than give a single number. Measured according to TM-21 and reported as L90B05: 360,000 hours at +50 °C, 103,000 hours at +85 °C, 71,700 hours at +105 °C, and 51,400 hours at +120 °C. Even that last value is still well over fourteen years at ten burning hours per day.
No. Due to the high temperatures, lenses are not possible; the HT has a single beam angle of 120 degrees, very wide, with a field angle of 168 degrees. If you need a directional beam in a hot zone, a floodlight from our high-temperature line is the right choice and not this canopy.
With 0-10V, PWM, DALI-2, or via NFC. With NFC, this is done using a smartphone or a programming device, without opening the luminaire and without disconnecting the power. Convenient on a canopy, where every action on a hanging luminaire requires a cherry picker. A position above the pumps can thus be set higher than a position above the drive-through lane.
Not on the standard versions: the driver is internal and the fixture operates directly from 90 to 305 volts. On the HT version it is, and that is intentional: drivers are more sensitive to heat than the LED module itself, so in a hot zone the driver is the component that fails first. Placed outside the zone, the thermal load decreases and maintenance is possible without entering the hot area.
That follows from the dimensions of the awning, the height of the bottom, and the desired light level. As a rule of thumb for a canopy, the spacing should be approximately equal to the height; too far apart will result in dark areas between the positions. We will calculate it and provide the positions and the wattage per position.
EN 12464-2 sets the requirements for the lighting of outdoor workplaces, and a petrol station canopy falls under that: illuminance, uniformity and glare. We assess the calculation against this. If the station borders on residential areas or nature, the NSVV guideline on light nuisance also applies.
No. For many petrol station canopies, the general lighting falls outside the ATEX zone, but this must always be checked per location and zoning plan. If your situation requires a certified luminaire within the zone, we will state this in advance and refer you to another supplier.
CE and IEC/EN 60598-1 and -2-5 for luminaire safety. EMC emission and immunity have been tested by TÜV according to EN 55015 and EN 61547, and for maritime applications IEC 60533 for engine room, bridge and open deck. Furthermore, IEC 60529 and ISO 20653 for ingress protection classes, IEC 62262 for IK08, ISO 9223 class C5 for corrosion, and RoHS and REACH by self-declaration.
IP69K means completely dust- and waterproof, including cleaning with a high-pressure water jet at close range. Under a canopy, that is not excessive: water and foam are used at a car wash or gas station, and the canopy hangs right in the middle of it. IK08 is the impact resistance of the front; the front is diffuse chemically tempered glass or diffuse borosilicate glass.
Maintenance is the real cost factor for a canopy: each service requires an aerial lift and usually a cordoned-off area. The fixture itself has no wear parts; the recommended inspection is limited to cleaning the front and checking the mounting and the cable entry. On the HT model, the driver is located externally and can be replaced without disassembling the fixture.
The WP is a wall-mounted fixture with a full cut-off reflector that directs the light forward. The Manta hangs beneath an awning or ceiling and illuminates the floor below it. Different positions, different light patterns; they are not interchangeable.
A five-year limited product warranty on all models, including the HT. For larger projects and chains with multiple locations, extended warranty agreements are negotiable; we tailor these on a case-by-case basis.
Provide the dimensions of the canopy, the height and the number of positions, plus what is currently installed. We will determine the number of fixtures, the power per position, the optics and the design, and put the energy consumption next to your current installation.
You will receive a response from the person who is also preparing your lighting calculation.
We use your information solely to review your request and respond to it.