Home / Products / Snapper HC

Snapper HC LED Floodlight

Maximum light per kilogram on the crane: up to 83,000 lumens at 12.6 kg, made up of cast light modules. For STS and RMG cranes and mobile lighting towers.

A multi-configuration model: two or three molded light modules on a single bracket, without seams or end caps. Available in AC and 24 V DC, with three bracket options and a safety cord as standard.

Response within 1 business day by an engineer. Free lighting calculation and trial luminaire possible.

Product rendering of the Snapper HC floodlight with side and top mounting options

The x3 configuration: three cast light modules on a single 316L bracket.

Luminous flux
83,000 lm

500 W, 166 lm/W

Protection
IP68

also IP66 and IP67

Light modules
2 of 3

cast from a single mold, each with its own lens

Trilling
6 G

at resonance, IEC 60068-2-6

Warranty
5 years

on the entire luminaire

Weight
12.6 kg

the x3, with 83,000 lumens

Decision Aid

When should you choose the Snapper HC?

Net yield per kilogram is the basis for the design: plenty of light per mounting point, without adding extra weight or wind resistance to the structure.

  • STS, RMG or other port cranes require maximum light per mounting point
  • The luminaire is mounted on and removed from a mobile lighting tower each time
  • The mounting position requires a top mount, side mount, or Crane Light Stabilizer
  • The weight on the structure or boom must be kept limited at high light output
  • AC and DC occur within a single fleet
  • Need more output than a single Snapper, without upgrading to the Orca

When another luminaire fits better

The Snapper HC is not intended for every task. Being clear about its limitations leads to a better end result.

  • One compact floodlight is all you need: then the Snapper or the Barracuda
  • A maximum impact resistance rating of IK10 is a strict requirement; the Snapper HC has an IK08 rating: therefore, the Marlin
  • Need more than 83,000 lumens from a single luminaire? Then the Orca
  • Complete light blocking against light pollution is required: then DarkLicht
  • ATEX or Ex certification is required
  • A high-temperature version is required: in that case, the Snapper HT or the Barracuda HT
Versions

Three configurations

One cast light module as a base, two or three of the same modules on a single bracket. What differs is the number of modules and the power supply.

Product rendering of a Snapper HC floodlight with top mounting

Snapper HC x1

31,000 lm at 180 W

Technically speaking, it's not an HC, but rather the single unit on which the series is based: 180 W and 31,000 lumens from the same die-cast design. The product is the Snapper.

SNAC01

Product rendering of two Snapper HC compact industrial floodlights

Snapper HC x2

44,100 – 55,000 lm

Two cast lighting modules on a single bracket, weighing a total of 9.9 kg. AC versions in 270 or 320 W up to 55,000 lm; the 300 W 24 V DC version is the standard choice for mobile light towers.

SNHC01 · SNHC02

Product rendering of three Snapper HC compact floodlights

Snapper HC x3

66,200 – 83,000 lm

Three cast light modules on a single bracket, totaling 12.6 kg. AC input 400 or 500 W up to 83,000 lm, DC 24 V from 450 W. The workhorse for STS and RMG cranes.

SNHC03 · SNHC04

Product family

The Snapper HC's place within the product family

Five floodlights, increasing in output. The right choice depends on what the position requires: weight, range, or maximum lumens per housing.

LuminaireRole in the rangePowerIP and IKWeight
Product Render MarlinMarlin
18,000 lumens
The link between work lights and heavy-duty floodlights.120 WIP69K / IK105.5 kg
Product Render SnapperSnapper
31,000 lumens
The compact light-duty floodlight, with maximum lumens per weight.150 to 180 WIP68 / IK083.1 kg
Product Render Snapper HCSnapper HC
83,000 lumens
Two or three cast modules on a single bracket: maximum light per kilogram.270 to 500 WIP68 / IK0812.6 kg
Product Render BarracudaBarracuda
44,100 lumens
Most powerful compact floodlight, with more output and more range.240 to 320 WIP69K / IK1010.1 kg
Product Rendering SharkShark
50,000 lumens
More efficient floodlight, with the lowest weight per lumen.320 WIP69K / IK109.2 kg
Product Render OrcaOrca
111,300 lumens
Heaviest floodlight, for the highest lumen output per housing.800 WIP69K / IK0922.7 kg
Specifications

Full specification

The x2 and x3 are each available in AC and 24 V DC; the single x1 completes the range. Choose a version and the complete specification list below changes accordingly, including dimensions, weight, and current consumption.

Item number

SNAC01-65K · also 50K, 40K, 30K and 22K

The single-piece molded unit on which the series is based; the product is the Snapper. The ideal choice when a single compact unit per position is sufficient.

Product rendering of a Snapper HC floodlight with top mounting

31,000 lm

Light
Luminous flux31,000 lm
Power consumption180 W
Efficiency172 lm/W
Optics15° spot, 30°, 60°, 90°, 20° × 50° and 20° × 85°; selectable per light module.
Color temperatures5000K, 4000K, 2700K and amber 2200K
Bi-color4000K with amber 2200K, switchable during operation
CRI (Ra)> 70, or optionally 80 or 90
Color consistency3-step MacAdam
Electric
Voltage range90–305 VAC
Nominal voltageNot applicable to AC
Current drawapprox. 0.8 A at 220 V · 1.7 A at 110 V
Dimming0–10 V, PWM, and DALI-2, or via NFC
Driverremote BLD240, can in DRB-1
Driver TypeBLD240, 240 W
Inrush current66 A peak, T50 0.5 ms at 220 V
Luminaires per MCBB16: 3 · C16: 6 · C25: 9 · D16: 10
Surge protection6 kV line-to-line, 10 kV line-to-ground (IEC 61000-4-5)
Labor Factor and THD> 0.95 at 60–100 % load, THD < 15 % at 65–100 %
Construction
Housingcast aluminum light modules, < 0.08 % copper
Surface treatmenttitanium e-coating, 2-layer
Brackethigh tensile strength 316L stainless steel, ± 180° in steps of 30°
Frontimpact-resistant glass IK08
ColorTitanium Black or Titanium Grey
Dimensions312 × 181 × 118 mm
Weight3.1 kg
Lead timeStandard within a week, custom by arrangement
Cable typeH07BQ-F, 4-wire (2 × 2.5 mm² + 2 × 0.5 mm²), 2.0 m
Connectionpre-assembled cable, loose wires
AccessoriesTop-mount bracket · Side-mount bracket · Crane Light Stabilizer
Protection and durability
IP RatingsIP66, IP67 and IP68
Impact ResistanceIK08
Corrosion classC5 Industrial and Maritime (ISO 9223)
Vibration class6 G at resonance (IEC 60068-2-6), shock IEC 60068-2-27
Operating temperature−45 to +50 °C
LED lifespanTM-21 L90B05 > 360,000 hours
Driver lifespan≥ 100,000 hours at Tc 75 °C, ≥ 130,000 hours at Tc 50 °C
MTBF driver≥ 280,000 hours at Tc 75 °C (MIL-HDBK-217F)
Warranty5 years on the complete luminaire
CertificationCE, IEC 60598, EN 55015, EN 61547, EMC. North America upon request.
Packagingdepending on quantity, upon request

Item number

SNHC02-50K · also 40K, 30K and 22K

Two modules on a single bracket, for AC power. Programmable via NFC to 270 W.

Render of two Snapper HC floodlights for STS crane lighting

55,000 lm

Light
Luminous flux55,000 lm, at 270 W 49,500 lm
Power consumption320 of 270 W
Efficiency172 lm/W
Optics15° spot, 30°, 60°, 90°, 20° × 50° and 20° × 85°; selectable per light module.
Color temperatures5000K, 4000K, 2700K and amber 2200K
Bi-color4000K with amber 2200K, switchable during operation
CRI (Ra)> 70, or optionally 80 or 90
Color consistency3-step MacAdam
Electric
Voltage range90–305 of 180–528 VAC
Nominal voltageNot applicable to AC
Current drawapprox. 0.8 A at 380 V · 1.5 A at 220 V · 2.9 A at 110 V
Dimming0–10 V, PWM, and DALI-2, or via NFC
Driverremote BLD320, can in DRB-1
Driver TypeBLD320, 320 W
Inrush current31.2 A peak, T50 1.3 ms at 220 V
Luminaires per MCBB16: 2 · C16: 4 · C25: 7 · D16: 8
Surge protection6 kV line-to-line, 10 kV line-to-ground (IEC 61000-4-5)
Labor Factor and THD> 0.95 at 60–100 % load, THD < 15 % at 60–100 %
Construction
Housingcast aluminum light modules, < 0.08 % copper
Surface treatmenttitanium e-coating, 2-layer
Brackethigh tensile strength 316L stainless steel, ± 180° in steps of 30°
Frontimpact-resistant glass IK08
ColorTitanium Black or Titanium Grey
Dimensions320 × 314 × 205 mm
Weight9.9 kg
Cable typeH07BQ-F, 4-wire (2 × 2.5 mm² + 2 × 0.5 mm²), 2.0 m
Connectionpre-assembled cable, loose wires
AccessoriesTop-mount bracket · Side-mount bracket · Crane Light Stabilizer
Protection and durability
IP RatingsIP66, IP67 and IP68
Impact ResistanceIK08
Corrosion classC5 Industrial and Maritime (ISO 9223)
Vibration class6 G at resonance (IEC 60068-2-6), shock IEC 60068-2-27
Operating temperature−45 to +50 °C
LED lifespanTM-21 L90B05 > 360,000 hours
Driver lifespan≥ 100,000 hours at Tc 75 °C, ≥ 130,000 hours at Tc 50 °C
MTBF driver≥ 280,000 hours at Tc 75 °C (MIL-HDBK-217F)
Warranty5 years on the complete luminaire
CertificationCE, IEC 60598, EN 55015, EN 61547, EMC. North America upon request.
Packagingdepending on quantity, upon request

Item number

SNHC01-50K · also 40K, 30K, and 22K

The standard choice for mobile lighting towers: connects directly to the 24 V vehicle electrical system.

Product rendering of two Snapper HC compact floodlights

44,100 lm

Light
Luminous flux44,100 lm
Power consumption300 W
Efficiency147 lm/W
Optics15° spot, 30°, 60°, 90°, 20° × 50° and 20° × 85°; selectable per light module.
Color temperatures5000K, 4000K, 2700K and amber 2200K
Bi-color4000K with amber 2200K, switchable during operation
CRI (Ra)> 70, or optionally 80 or 90
Color consistency3-step MacAdam
Electric
Voltage range20–35 VDC
Nominal voltage24 V
Current drawapprox. 12.5 A at 24 V
Dimmingcustom work
DriverDC driver circuit board
Driver Typenot applicable, driver on board
Inrush currentnot applicable, driver on board
Luminaires per MCBnot applicable, driver on board
Surge protectionnot applicable, driver on board
Labor Factor and THDnot applicable, driver on board
Construction
Housingcast aluminum light modules, < 0.08 % copper
Surface treatmenttitanium e-coating, 2-layer
Brackethigh tensile strength 316L stainless steel, ± 180° in steps of 30°
Frontimpact-resistant glass IK08
ColorTitanium Black or Titanium Grey
Dimensions320 × 314 × 205 mm
Weight9.9 kg
Cable typeH07BQ-F, 4-wire (2 × 2.5 mm² + 2 × 0.5 mm²), 2.0 m
Connectionpre-assembled cable, loose wires
AccessoriesTop-mount bracket · Side-mount bracket · Crane Light Stabilizer
Protection and durability
IP RatingsIP66, IP67 and IP68
Impact ResistanceIK08
Corrosion classC5 Industrial and Maritime (ISO 9223)
Vibration class6 G at resonance (IEC 60068-2-6), shock IEC 60068-2-27
Operating temperature−45 to +50 °C
LED lifespanTM-21 L90B05 > 360,000 hours
Driver lifespannot applicable
MTBF drivernot applicable, driver on board
Warranty5 years on the complete luminaire
CertificationCE, IEC 60598, EN 55015, EN 61547, EMC. North America upon request.
Packagingdepending on quantity, upon request

Item number

SNHC04-50K · also 40K, 30K and 22K

The workhorse for STS and RMG cranes: three modules, 83,000 lumens and 12.6 kg on a single mounting point.

Product rendering of three Snapper HC floodlights for STS crane lighting

83,000 lm

Light
Luminous flux83,000 lm, at 400 W 73,000 lm
Power consumption500 of 400 W
Efficiency166 lm/W
Optics15° spot, 30°, 60°, 90°, 20° × 50° and 20° × 85°; selectable per light module.
Color temperatures5000K, 4000K, 2700K and amber 2200K
Bi-color4000K with amber 2200K, switchable during operation
CRI (Ra)> 70, or optionally 80 or 90
Color consistency3-step MacAdam
Electric
Voltage range90–305 of 180–528 VAC
Nominal voltageNot applicable to AC
Current drawapprox. 1.4 A at 380 V · 2.3 A at 220 V · 4.6 A at 110 V
Dimming0–10 V, PWM, and DALI-2, or via NFC
Driverremote TLD400 (400 W) or TLD600 (500 W), can be used in the DRB-2
Driver TypeTLD400 or TLD600
Inrush current64 A (TLD400) or 5.4 A (TLD600) peak, T50 400 µs at 220 V
Luminaires per MCBB16: 3 · C16: 3 · C25: 5 · D16: 4
Surge protection6 kV line-to-line, 10 kV line-to-ground (IEC 61000-4-5)
Labor Factor and THD> 0.9 at 60–100 % load, THD < 15 % at 60–100 %
Construction
Housingcast aluminum light modules, < 0.08 % copper
Surface treatmenttitanium e-coating, 2-layer
Brackethigh tensile strength 316L stainless steel, ± 180° in steps of 30°
Frontimpact-resistant glass IK08
ColorTitanium Black or Titanium Grey
Dimensions320 × 484 × 205 mm
Weight12.6 kg
Cable typeH07BQ-F, 4-wire (2 × 2.5 mm² + 2 × 0.5 mm²), 2.0 m
Connectionpre-assembled cable, loose wires
AccessoriesTop-mount bracket · Side-mount bracket · Crane Light Stabilizer
Protection and durability
IP RatingsIP66, IP67 and IP68
Impact ResistanceIK08
Corrosion classC5 Industrial and Maritime (ISO 9223)
Vibration class6 G at resonance (IEC 60068-2-6), shock IEC 60068-2-27
Operating temperature−45 to +50 °C
LED lifespanTM-21 L90B05 > 360,000 hours
Driver lifespan≥ 100,000 hours at Tc 75 °C, ≥ 130,000 hours at Tc 50 °C
MTBF driverTLD400 ≥ 280,000 hours, TLD600 ≥ 320,000 hours at Tc 75 °C (MIL-HDBK-217F)
Warranty5 years on the complete luminaire
CertificationCE, IEC 60598, EN 55015, EN 61547, EMC. North America upon request.
Packagingdepending on quantity, upon request

Item number

SNHC03-50K · also 40K, 30K and 22K

The heaviest 24 V configuration, for mobile light towers and machinery with an ample on-board power grid.

Product rendering of three Snapper HC compact floodlights

66,200 lm

Light
Luminous flux66,200 lm
Power consumption450 W
Efficiency147 lm/W
Optics15° spot, 30°, 60°, 90°, 20° × 50° and 20° × 85°; selectable per light module.
Color temperatures5000K, 4000K, 2700K and amber 2200K
Bi-color4000K with amber 2200K, switchable during operation
CRI (Ra)> 70, or optionally 80 or 90
Color consistency3-step MacAdam
Electric
Voltage range20–35 VDC
Nominal voltage24 V
Current drawapprox. 18.8 A at 24 V
Dimmingcustom work
DriverDC driver circuit board
Driver Typenot applicable, driver on board
Inrush currentnot applicable, driver on board
Luminaires per MCBnot applicable, driver on board
Surge protectionnot applicable, driver on board
Labor Factor and THDnot applicable, driver on board
Construction
Housingcast aluminum light modules, < 0.08 % copper
Surface treatmenttitanium e-coating, 2-layer
Brackethigh tensile strength 316L stainless steel, ± 180° in steps of 30°
Frontimpact-resistant glass IK08
ColorTitanium Black or Titanium Grey
Dimensions320 × 484 × 205 mm
Weight12.6 kg
Cable typeH07BQ-F, 4-wire (2 × 2.5 mm² + 2 × 0.5 mm²), 2.0 m
Connectionpre-assembled cable, loose wires
AccessoriesTop-mount bracket · Side-mount bracket · Crane Light Stabilizer
Protection and durability
IP RatingsIP66, IP67 and IP68
Impact ResistanceIK08
Corrosion classC5 Industrial and Maritime (ISO 9223)
Vibration class6 G at resonance (IEC 60068-2-6), shock IEC 60068-2-27
Operating temperature−45 to +50 °C
LED lifespanTM-21 L90B05 > 360,000 hours
Driver lifespannot applicable
MTBF drivernot applicable, driver on board
Warranty5 years on the complete luminaire
CertificationCE, IEC 60598, EN 55015, EN 61547, EMC. North America upon request.
Packagingdepending on quantity, upon request

All values above are also listed on the datasheet, including dimensions and order code.

For the installer

Driver, circuit loading and protection

The AC drivers are separate from the luminaire and can be placed in the DRB-1 or DRB-2 driver box. The values below are from the Upowertek datasheets and apply per driver, not per luminaire.

Driver AC
BLD320

320 W, remote, for the x2

Inrush current
31.2 A peak

for the x2 · x3 with TLD600: 5.4 A

Overvoltage
6 / 10 kV

line-to-line / line-to-earth, IEC 61000-4-5

MTBF driver
280,000 h

at Tc 75 °C, MIL-HDBK-217F

Maximum number of drivers per miniature circuit breaker
DriverB16C16C25D16
BLD240 · x1 180 W36910
BLD320 · x2 AC 320 W2478
TLD600 · x3 AC 500 W3354

Calculated with ABB S200 at 220 V, from the manufacturer's MCB table. Guideline for the engineering phase and not a replacement for the installation calculation; for verification we provide a lighting advice and installation calculation. If there are multiple drivers in one luminaire, divide the number by that number of drivers.

Other electrical
  • Power factor > 0.95 at x1 and x2, > 0.9 at x3
  • THD < 15 % at a load of 60 to 100 %
  • Driver lifetime ≥ 100,000 h at Tc 75 °C, ≥ 130,000 h at Tc 50 °C
  • Dimming with 0–10 V, PWM and DALI-2, or via NFC
  • Leakage current max. 0.7 mA at 240 VAC, IEC 60598-1
  • High-voltage DC 250 to 740 V upon request
Optics

Optics and measured beam angles

Each light module within the configuration can be given its own lens, allowing a single luminaire to illuminate multiple zones simultaneously. Below are the angles from our own IES library, with the optic name as the ordering code next to it. An optic name is not a measured value: the 30° optic measures a 29° beam and 73° field angle. If you are in doubt between two angles, we will substantiate the choice with a free lighting calculation.

Light pattern of the 15-degree spot lens
Side view of the Snapper HC with the 15-degree beam angle

15° spot

Driving light for long distance, 40 to 200 m

Light pattern of the 30-degree wide-angle lens
Side view of the Snapper HC with the 30-degree beam

30° floodlight

Medium range, 25 to 80 m; measured on the HC x3

Light pattern of the 60 degree wide beam optic
Side view of the Snapper HC with the 60-degree beam

60° wide-angle spotlight

Wide illumination close up, 15 to 50 m

Optical image: 90-degree ultra-wide angle
Side view of the Snapper HC with the 90-degree beam

90° extra wide

Area lighting up to 25 m; also 20° × 50° and 20° × 85° asymmetric

OpticsBeam angle 50 %Veldhoek 10 %Application distance
15° spot15° nominalnot measured yet40 to 200 m
30°29°73°25 to 80 m, measured on the Snapper HC x3 at 83,000 lm
60°60° nominalnot measured yet15 to 50 m
90°90° nominalnot measured yetup to 25 m, close by
20° × 50° en 20° × 85°face valuenot measured yetasymmetrical, for elongated zones

The beam angle is the full angle between the directions in which the intensity has decreased to 50 % of the peak; the field angle is 10 %. Combinations of optics within a single luminaire are possible; the asymmetric 20° × 50° and 20° × 85° options are also available. Optics that have not yet been measured are listed with their nominal values.

Mounting

Video editing software

On cranes, the mounting method determines whether a luminaire will last its full service life. The Snapper HC offers three mounting options,standard, top mount, and side mount,allowing it to be installed in virtually any position.

Technical Dimension Drawing of the Snapper SN2 Floodlight

Top mount bracket

For mounting suspended under the crane girder, the platform, or the ceiling. The modules remain adjustable in 30° increments.

Technical Dimension Drawing of the Snapper SN2 Floodlight

Side mount bracket

For mounting against a rafter or wall, with the bundle transverse to the construction.

Crane with stabilizing bracket and LED floodlights in Capelle

Crane Light Stabilizer

Self-stabilizing suspension that keeps the lamp level in a crane jib, so that the beam remains aimed at the work zone at every jib stage.

Product rendering of two Snapper HC compact floodlights

Standard bracket, ± 180°

High tensile strength 316L bracket, adjustable in 30° increments. Each luminaire comes with a safety cable.

A safety cable is included as standard with every luminaire. The DRB-1 or DRB-2 driver box houses the remote driver, either on the structure or in the cabinet. The Crane Light Stabilizer has its own product page. For tower cranes see also Tower crane lighting.

Dimensioning

Dimensioning

All dimensions in millimeters. The mounting pattern and bracket cross-sections are in the datasheet; DXF and STEP files are available upon request.

Technical Dimension Drawing of the Snapper SN2 Floodlight

Top mount layout drawing of the x3; the x2 drawing is on the datasheet.

Luminaire x1312 × 181 × 118 mm
Luminaire x2320 × 314 × 205 mm
Luminaire x3320 × 484 × 205 mm
Weight x1 · x2 · x33.1 · 9.9 · 12.6 kg
Bracket adjustment± 180°, in 30° increments
AC and DC Cable Length2.0 m
Safety lanyardincluded as standard
Packagingon request

The weight listed includes the bracket. Packaging dimensions and weight are included in the listing because JEL handles shipping.

Applications

Applications

Where the Snapper HC is installed in practice, and why there.

STS ship-to-shore crane with Snapper HC lighting in operation above containers

Harbor cranes, STS and RMG

More light per mounting point without extra weight and windage on the structure. The x3 delivers 83,000 lumens from 12.6 kg, with each module featuring its own lens.

2AXL light poles illuminate a mining site at night

Mobile lighting towers

Light enough to assemble and dismantle daily. The x2 DC 24 V is the standard choice on mobile masts.

Product rendering of the Snapper HC floodlight with side and top mounting options

Cranes and lifting equipment

With the top mount under the crane girder, the side mount against the truss, or the Crane Light Stabilizer in the boom.

Illuminated quay of the KNRM at night

Maritime and offshore

For ships and work decks where each position requires a high level of light while keeping weight to a minimum. Titanium e-coating and corrosion class C5 are standard.

Product rendering of two Snapper HC compact industrial floodlights
Construction

Molded light modules, without seams or end caps

Whereas comparable multi-unit luminaires are assembled from an extruded profile with end caps, each light module of the HC is cast from a single mold: fewer seams, fewer seals, and a lower risk of leakage.

Two or three modules share a single bracket and a single cable, and each module can be equipped with its own lens, allowing a single luminaire to illuminate multiple zones at the same time.

Light modulescast from a single mold, < 0.08 % copper
Configurationsx2 and x3, of x1 as a single unit
Lenses per moduleto choose separately
Safety lanyardincluded as standard

Originating from a request by terminals. See also Ports and terminals.

Evidence

Tested, not promised

Every claim carries its condition in the same sentence. You can read more about the test methods at Product Quality and Warranty.

Salt Spray · ISO 9227
1,007 hours

Neutral salt spray test in accordance with ISO 9227, performed on a cast housing that had been scratched beforehand: no coating delamination after 1,007 hours.

Vibration · IEC 60068-2-6
6 G continuous

Vibration-resistant up to 6 G at resonance in accordance with IEC 60068-2-6, with shock testing in accordance with IEC 60068-2-27.

Practice
On STS and RMG cranes

Developed in response to a request from terminal operators: more light per mounting point without adding weight or increasing wind resistance. Port cranes in Europe, Australia, and the United States are equipped with the HC.

Downloads

Downloads

Data Sheet

Four pages with the full specification, dimensions and order code. Available for immediate download.

3D file

STEP or DXF for your own drawing work, including the mounting pattern of the bracket.

Photometric files

All 15 versions and optics of the Snapper HC in EULUMDAT (.ldt) format, combined into a single 0.5 MB ZIP file. DIALux and Relux can read these files directly. The part number is included in the file name and within the file itself. We provide IES files upon request.

FAQ

Frequently Asked Questions

Is your question not listed, or would you like something calculated? An engineer will respond within 1 business day.

The base is the same cast light module. The Snapper is that module as a standalone luminaire; the HC mounts two (x2, up to 55,000 lm at 9.9 kg) or three (x3, up to 83,000 lm at 12.6 kg) on a single bracket, with a single cable and a single mounting point. The Orca is capable of producing more than 83,000 lumens from a single luminaire.

Per configuration: the x1 with BLD240 3 on a B16, 6 on a C16, 9 on a C25 and 10 on a D16; the x2 with BLD320 2, 4, 7 and 8; the x3 with TLD600 3, 3, 5 and 4. Calculated with ABB S200 at 220 V, per driver. It is a guideline for the engineering phase and not a replacement for the installation calculation.

Yes. Within one x2 or x3, each light module can be given its own optics, from 15° spot to 90° wide and the asymmetrical 20° × 50° and 20° × 85°. This way, a single mounting point can simultaneously illuminate, for example, the row of containers nearby and the area further away.

Yes. The AC versions are dimmable via 0–10 V, PWM, and DALI-2, and can also be configured via NFC. For the DC versions, dimming is customized because a constant current is used there.

Similar multi-unit luminaires are built from an extruded profile with end caps; every seam there is a seal that can age. Each HC module comes from a single mold, without seams or end caps, and is tested to IP66, IP67, and IP68.

Yes. The modules contain less than 0.08 % of copper and have a 2-layer titanium-based e-coating; the bracket is 316L. This corresponds to corrosion class C5 Industrial and Maritime. There is no fully 316L version of the HC; if that requirement is mandatory, consider the Snapper 316L or the Barracuda 316L.

However, for crane positions outside the immediate working area: IK08 with impact-resistant glass can withstand normal industrial use and weather conditions. If maximum impact resistance (IK10) is a strict requirement, choose the Marlin or the Barracuda.

Yes. The vibration rating is 6 G at resonance, tested in accordance with IEC 60068-2-6, with shock testing in accordance with IEC 60068-2-27. Each luminaire comes with a safety cord, and the Crane Light Stabilizer model is available for crane booms.

The 360,000 hours is a TM-21 L90B05 value: at that point, at least 95 % of the luminaires will still be delivering at least 90 % of their initial light output. This is more stringent than the standard L70 and L80 specifications. In practice, the LED is rarely the limiting factor; environmental conditions and installation quality determine the luminaire’s actual performance in the field.

No. The luminaire is not intended for hazardous areas. If ATEX is a requirement, please discuss this in advance, and we will determine a suitable solution together.

Yes. On mobile lighting towers, the x2 DC 24 V is a standard OEM choice, and on harbor cranes, the x3 is included as a standard component. For series production, we tailor the configuration, optics, voltage, and bracket to the design.

CE, IEC 60598, EN 55015, EN 61547 and the EMC Directive. IEC 60598 covers construction, electrical safety, and thermal behavior. In addition, the luminaire helps meet EN 12464-2 for the safe lighting of industrial outdoor workplaces. Configurations for North America are available upon request.

Request

Discuss your Snapper HC application

Tell us about the application, the location, and the scope of the project. We'll help you choose the design, the finish, and the mounting hardware.

Portrait photo of Lucas de Graaf

Lucas de Graaf

Technical Director, JEL Products

You will receive a response from the person who is also preparing your lighting calculation.

  • A reply within one working day, from an engineer
  • Free lighting calculation with number of luminaires and lux
  • Test luminaire possible before you decide
  • 5-year warranty on the complete luminaire
Rather direct contact
We respond within one working day. We deliver standard items within a week. Custom work, such as a different light colour, a different CRI or a bespoke version, by arrangement.

We use your information solely to review your request and respond to it.