You protect industrial luminaires against corrosion and high temperatures by choosing the right combination of material, protection rating and construction design for the specific environment. Aluminium with a coated finish is sufficient in many situations, but in highly corrosive or thermal environments, stainless steel housings or specially designed high-temperature luminaires are necessary. This article answers the most frequently asked questions about protection, choice of materials and extending the lifetime of Industrial LED luminaires.
Which environmental factors damage industrial luminaires the fastest?
The biggest enemies of industrial luminaires are moisture, chemical fumes, dust, mechanical shock and extreme temperature changes. These factors often do not act separately, but reinforce each other. Corrosion, for example, accelerates sharply in combination with high humidity and salty sea air, while thermal load weakens the seals, making it easier for moisture to get in.
In practice, technicians see the most wear in environments where several factors are at play at once. Think of a port where salty sea air, rain, dust and mechanical vibration from cranes continuously act on the luminaires. Or a steelworks where heat, infrared radiation and metal dust together create an extreme load.
The most common damaging factors at a glance:
- Corrosive substances: sea air, acids, alkalis, solvents and industrial fumes attack housings and connections
- Moisture and condensation: water getting in damages electronics and causes short circuits
- Dust and dirt fine dust clogs cooling fins and raises the operating temperature of LED components
- Mechanical load vibration from machines, cranes or vehicles accelerates material fatigue
- Thermal extremes: large temperature changes make materials expand and contract, causing seals to crack
- Infrared radiation: direct exposure to radiant heat, such as near melting furnaces, drastically raises the internal component temperature
What are the differences between IP, IK and ATEX classifications?
IP, IK and ATEX are three separate classification systems, each describing a different aspect of protection. IP stands for protection against dust and water, IK for protection against mechanical impact, and ATEX for safe use in potentially explosive environments. They complement each other and are often applied in combination.
For a complete picture of what these ratings mean in practice, it helps to understand each system separately. You will find more details about the exact meaning of the digits on the IP and IK Rating Page.
IP protection: dust and water
The IP code consists of two digits. The first digit indicates protection against solid particles (from 0 to 6), the second protection against water (from 0 to 9K). A luminaire with IP66 is completely dust-tight and resistant to powerful water jets. In outdoor environments or environments with spray water, IP65 or higher is the usual minimum requirement for industrial LED lighting.
IK protection: mechanical impact
The IK code runs from IK00 to IK10 and indicates how many joules of impact energy a luminaire can withstand. IK08 means resistant to 5 joules, IK10 to 20 joules. In environments with heavy machinery, moving vehicles or explosion risk, a high IK value is just as important as a high IP value.
ATEX: potentially explosive zones
ATEX lighting is mandatory in environments where flammable gases, vapours or dust clouds may occur. The classification determines in which zone (zone 0, 1, 2 for gas or zone 20, 21, 22 for dust) a luminaire may be used safely. This goes beyond just the housing: the electrical components, connections and installation method are also subject to strict requirements.
Which materials are most resistant to corrosion in industrial lighting?
For corrosion-resistant lighting in industrial environments are stainless steel (316L), high-grade aluminium with a protective coating and glass-fibre reinforced polyester. Each has its own strengths depending on the type of corrosive load.
Aluminium is light, conducts heat well and is suitable for most outdoor applications. An anodised or powder coating considerably increases its corrosion resistance. In environments with salty sea air or mild chemicals, coated aluminium is often sufficient and cost-effective.
Type 316L stainless steel contains molybdenum, which greatly increases resistance to chlorides and acids compared with standard 304 steel. This makes it the preferred choice for offshore applications, the chemical industry and environments with aggressive cleaning agents. The material is heavier and more expensive, but offers a significantly longer lifetime in extremely corrosive conditions.
Glass-fibre reinforced polyester (GRP) is chemically inert and does not rust. It is used in environments with aggressive acids or alkalis where even stainless steel can be attacked. The downside is its lower thermal conductivity, which makes thermal management more complex.
How do high-temperature luminaires work in extreme heat and infrared radiation?
High-temperature luminaires are designed to keep functioning reliably at ambient temperatures that push standard LED luminaires far beyond their limits. They combine special cooling technology, heat-resistant materials and protective housings to isolate the LED components from the external heat load.
The core problem with high temperature lighting is that LEDs are sensitive to heat. The higher the temperature of the LED junction, the faster the light output drops and the shorter the lifetime. In a steelworks or foundry, the ambient temperature can rise above 100°C, while direct infrared radiation from molten metal or furnaces adds extra heat that cannot be dissipated via conventional cooling fins.
Solutions used in high-temperature luminaires include active cooling systems, thermally conductive potting compound around electronics, heat-resistant optical components and reflective housings that bounce back infrared radiation. The Orca and Barracuda floodlights in the HT version have been developed specifically for these conditions and are reliable up to ambient temperatures of +120°C, with passive cooling via cooling fins rather than active cooling.
When do you choose stainless steel luminaires instead of aluminium?
Stainless steel luminaires are the better choice when the environment contains chlorides, strong acids, alkalis or aggressive cleaning agents that attack aluminium. In offshore and maritime applications, the food industry and chemical plants, stainless steel is also the standard because of its superior corrosion resistance.
The trade-off is not only technical but also economic. Stainless steel has a higher purchase price, but in corrosive environments the total cost of ownership is often lower because the luminaires need replacing less often and require less maintenance. Aluminium luminaires can show surface corrosion within a few years in the same environment, even with a coating, while 316L steel remains intact for decades.
Choose aluminium when:
- The environment is dry or moderately damp without aggressive chemicals
- Weight matters, for example for crane mounting or mobile applications
- Thermal management is a priority, because aluminium dissipates heat better
- The budget is more limited and the environmental load justifies it
Choose stainless steel when:
- The location is exposed to sea air, chlorides or chemicals
- Hygiene requirements apply, such as in the food industry
- High-pressure washing or intensive cleaning is part of operations
- Long maintenance intervals are required at hard-to-reach locations
How do you extend the lifetime of luminaires in aggressive environments?
You extend the lifetime of industrial LED luminaires in aggressive environments by choosing the right luminaire for the specific load, carrying out the installation correctly and following a well-thought-out maintenance schedule. Prevention is more effective than repair here.
A structured approach looks like this:
- Environmental analysis beforehand: map the specific loads (temperature, corrosive substances, vibration, accessibility) before selecting a luminaire
- Select the right classification: make sure the IP, IK and any ATEX class match the actual conditions, not just the average situation
- Correct installation: use the right cable glands, seals and fixing materials that are compatible with the housing and the environment
- Periodic inspection: check seals, fixings and optical components for signs of wear or corrosion
- Targeted cleaning: remove dust and deposits from cooling fins to prevent overheating, and use cleaning agents that are compatible with the luminaire material
- Monitor thermal management: make sure cooling fins are not blocked by a build-up of dust or dirt, especially in high-temperature environments
An often underestimated aspect is the cable entry. A perfectly sealed luminaire with a poorly sealed cable gland completely loses its IP protection. Attention to the complete installation, including connections and suspension, is just as important as the choice of luminaire itself.
Practical example: Farm Frites
Farm Frites was dealing with LED lighting that failed repeatedly in the drying tunnels and production ovens, due to the high thermal stress and the intensive cleaning routine. For the freezing tunnels, the lighting also had to withstand a range of -40 °C to +70 °C during the cleaning processes. JEL therefore designed a special version of the stainless steel Snapper HT: the Snapper HT-SS, with a stainless steel housing, borosilicate glass, a HACCP-compliant design and IP69K protection. 78 luminaires of 35 W each were supplied, achieving 200 to 500 lux in the oven.
Corrosion and heat attack the same places here. Thermal stress and high-pressure cleaning load the seal and the glass at the same time, and a stainless steel housing alone does not solve that. Borosilicate glass withstands large temperature changes and does not break under thermal shock, and IP69K is geared to cleaning at high pressure and high temperature.
Anyone who wants to protect luminaires against corrosion and heat should therefore choose the housing, glass and seal as a single whole.
Read more about the Farm Frites project
How JEL Products helps with protection against corrosion and high temperatures
JEL Products supplies lighting solutions designed specifically for environments where standard lighting falls short. The approach is technical and practical: not a standard catalogue, but a solution that matches the actual conditions at your site.
What JEL Products offers for corrosive and high-temperature environments:
- Specialised stainless steel lighting for offshore, the chemical industry and other highly corrosive environments
- High-temperature luminaires (Orca HT and Barracuda HT) for steelworks, foundries and other high-temperature environments up to +120°C
- Lighting for the site areas outside the ATEX zones, with referral to a certified Ex manufacturer for the zones themselves
- Lighting for climate chambers from -45°C, and with the HT line up to +120°C
- Complete solutions for extreme corrosion, including engineering and lighting design
- Support throughout the entire process: from technical analysis and choice of luminaire to installation and commissioning
- ISO 9001 and VCA** certified, with proven experience in high-profile industrial projects
Are you dealing with an environment where standard lighting does not do the job? Then get in touch via the JEL Products Contact Page for a technical conversation about your specific situation. Together we look at what the most durable and reliable solution is for your environment.
Related Articles
- How does high ambient temperature affect the energy consumption of lamps?
- What pitfalls are there when replacing lighting in hot installations?
- How does high humidity combined with heat affect the lighting?
- What is the difference between functional lighting and general area lighting in a port?
- How to prevent glare from industrial LED lighting?